Flávio Domingues das Neves

Flávio Domingues das Neves


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2014 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
FNFlávio Domingues das Neves
Flávio Domingues das Neves
CPCélio J. Prado
Célio J. Prado
MPMarcel S. Prudente
Marcel S. Prudente
TCThiago A.P.N. Carneiro
Thiago A.P.N. Carneiro
KZKarla Zancopé
Karla Zancopé
CSCarlos José Osé Soares
Carlos José Osé Soares

1 March 2018 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
MPMarcel S. Prudente
Marcel S. Prudente
LDLetícia R. Davi
Letícia R. Davi
KNKemilly O. Nabbout
Kemilly O. Nabbout
CPCélio J. Prado
Célio J. Prado
LPLeandro M. Pereira
Leandro M. Pereira
FNFlávio Domingues das Neves
Flávio Domingues das Neves

1 June 2015 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
KZKarla Zancopé
Karla Zancopé
GAGizella M. Abrão
Gizella M. Abrão
FKFrederick K. Karam
Frederick K. Karam
FNFlávio Domingues das Neves
Flávio Domingues das Neves

1 October 2012 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
JNJoão Paulo Da Silva Neto
João Paulo Da Silva Neto
MPMarcel Santana Prudente
Marcel Santana Prudente
TCThiago de Almeida Prado Naves Carneiro
Thiago de Almeida Prado Naves Carneiro
MNMauro Antônio de Arruda Nóbilo
Mauro Antônio de Arruda Nóbilo
MPMario Paulo Amante Penatti
Mario Paulo Amante Penatti
FNFlávio Domingues das Neves
Flávio Domingues das Neves
This study evaluated the microleakage at the implant/abutment interface of external hexagon (eH) implants and abutments with different amounts of bacteria and tightening torques. A bacterial suspension was prepared to inoculate the implants. The first phase of this study used nine EH implants and abutments that were divided into three groups with different amounts of bacterial suspension (n=3): V0.5: 0.5 µL; V1.0: 1.0 µL e V1.5: 1.5 µL, and tightened to the manufacturer's recommended torque. The second phase of this experiment used 27 assemblies that were similar to those used in the first phase. These samples were inoculated with 0.5 µL of bacterial suspension and divided into three groups (n=9). T10: 10 Ncm; T20: 20 Ncm and T32: 32 Ncm. The samples were evaluated according to the turbidity of the broth every 24 hours for 14 days, and the bacteria viability was tested after that period. The statistical evaluation was conducted by Kruskal-Wallis testing (p<.05). During the first phase, groups V1.0 and V1.5 was presented with bacterial contamination in all samples after 24 h. During the second phase, two samples from group T10 and one from T20 presented positive results for bacterial contamination. Different amounts of bacterial solution led to overflow and contamination during the first 24 h of the experiment. The tightening torques did not statistically affect the microleakage in the assemblies. However, the group that was tightened to 32 Ncm torque did not show any bacterial contamination. After 14 days of experimentation, the bacteria were proven to remain viable inside the implant internal cavity.

8 March 2006
Verified
Journal Article
Closed access
FNFlávio Domingues das Neves
Flávio Domingues das Neves
DFDennis Fones
Dennis Fones
SBSérgio Rocha Bernardes
Sérgio Rocha Bernardes
CPCélio Jesus Do Prado
Célio Jesus Do Prado
ANAlfredo Júlio Fernandes Neto
Alfredo Júlio Fernandes Neto

1 July 2019 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
TRTaís Alves dos Reis
Taís Alves dos Reis
KZKarla Zancopé
Karla Zancopé
FKFrederick Khalil Karam
Frederick Khalil Karam
FNFlávio Domingues das Neves
Flávio Domingues das Neves