19 July 2016 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
LDLucas Costa de Medeiros Dantas
Lucas Costa de Medeiros Dantas
JNJoão Paulo Da Silva Neto
João Paulo Da Silva Neto
TDTalita Souza Dantas
Talita Souza Dantas
LNLucas Zago Naves
Lucas Zago Naves
FNFlávio Domingues das Neves
Flávio Domingues das Neves
AMAdérito Soares da Mota
Adérito Soares da Mota
This study sought to assess the effect of different surface finishing and polishing protocols on the surface roughness and bacterial adhesion (S. sanguinis) to polymethyl methacrylates (PMMA). Fifty specimens were divided into 5 groups (n=10) according to their fabrication method and surface finishing protocol: LP (3 : 1 ratio and laboratory polishing), NF (Nealon technique and finishing), NP (Nealon technique and manual polishing), MF (3 : 1 ratio and manual finishing), and MP (3 : 1 ratio and manual polishing). For each group, five specimens were submitted to bacterial adhesion tests and analyzed by scanning electron microscopy (SEM). Two additional specimens were subjected to surface topography analysis by SEM and the remaining three specimens were subjected to surface roughness measurements. Data were compared by one-way ANOVA. The mean bacterial counts were as follows: NF,19.6±3.05; MP,5.36±2.08; NP,4.96±1.93; MF,7.36±2.45; and LP,1.56±0.62(CFU). The mean surface roughness values were as follows: NF,3.23±0.15; MP,0.52±0.05; NP,0.60±0.08; MF,2.69±0.12; and LP,0.07±0.02(μm). A reduction in the surface roughness was observed to be directly related to a decrease in bacterial adhesion. It was verified that the laboratory processing of PMMA might decrease the surface roughness and consequently the adhesion ofS. sanguinisto this material.

1 January 2011 in Brazilian Dental Journal
Verified
Journal Article
Open access
PDF file
GBGustavo Seabra Barbosa
Gustavo Seabra Barbosa
JNJoão Paulo Da Silva Neto
João Paulo Da Silva Neto
PJPaulo Cézar Simamoto Júnior
Paulo Cézar Simamoto Júnior
FNFlávio Domingues das Neves
Flávio Domingues das Neves
MMMaria da Gloria Chiarello de Mattos
Maria da Gloria Chiarello de Mattos
Ricardo Faria RibeiroRicardo Faria Ribeiro
Ricardo Faria Ribeiro
This study evaluated the loss of the torque applied after use of new screws and after successive tightening. Four infrastructures (IE), using UCLA castable abutment type, were cast in cobalt-chromium alloy and new abutment screws (G1) were used in a first moment. Subsequently, the same abutment screws were used a second time (G2) and more than two times (G3). The values of the torques applied and detorques were measured with a digital torque wrench to obtain the values of initial tightening loss (%). Data were analyzed by ANOVA and Tukey's test (?=0.05). Significant differences were observed between the G1 (50.71% ± 11.36) and G2 (24.01% ± 3.33) (p=0.000) and between G1 (50.71% ± 11.36) and G3 (25.60% ± 4.64) (p=0.000). There was no significant difference between G2 and G3 (p=0.774). Within the limitations of the study, it may be concluded that the percentage of the initial torque loss is lower when screws that already suffered the application of an initial torque were used, remaining stable after application of successive torques.

1 June 2015 in Brazilian Dental Journal
Verified
Journal Article
Open access
PDF file
GAGabriela Monteiro de Araújo
Gabriela Monteiro de Araújo
DFDanilo Gonzaga Bernardo de França
Danilo Gonzaga Bernardo de França
JNJoão Paulo Da Silva Neto
João Paulo Da Silva Neto
GBGustavo Augusto Seabra Barbosa
Gustavo Augusto Seabra Barbosa
The objective of this research was to evaluate the passivity by measuring the passive fit and strain development of frameworks screwed on abutments, made by CAD/CAM technology, and to compare these parts with samples manufactured by conventional casting. Using CAD/CAM technology, four samples were made from zirconia (Zircad) and four samples were manufactured from cobalt-chrome (CoCrcad). The control groups were four specimens of cobalt-chrome, made by one-piece casting (CoCrci), with a total of 12 frameworks. To evaluate the passive fit, the vertical misfit at the abutment-framework interface was measured with scanning electron microscopy (250×) when only one screw was tightened. The mean strain in these frameworks was analyzed by photoelasticity test. A significant difference in the passive fit was observed between the control and sample groups. CoCrcad exhibited the best value of passive fit (48.76±13.45 µm) and CoCrci the worst (187.55±103.63 µm); Zircad presented an intermediate value (103.81±43.15 µm). When compared to the other groups, CoCrci showed the highest average stress around the implants (17.19±7.22 kPa). It was concluded that CAD/CAM-fabricated frameworks exhibited better passivity compared with conventionally fabricated frameworks. CAD/CAM-fabricated Co-Cr frameworks may exhibit better passive fit compared with CAD/CAM-fabricated zirconia frameworks. Even so, similar levels of stress were achieved for CAD/CAM-fabricated frameworks.

1 October 2012 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
JNJoão Paulo Da Silva Neto
João Paulo Da Silva Neto
MPMarcel Santana Prudente
Marcel Santana Prudente
TCThiago de Almeida Prado Naves Carneiro
Thiago de Almeida Prado Naves Carneiro
MNMauro Antônio de Arruda Nóbilo
Mauro Antônio de Arruda Nóbilo
MPMario Paulo Amante Penatti
Mario Paulo Amante Penatti
FNFlávio Domingues das Neves
Flávio Domingues das Neves
This study evaluated the microleakage at the implant/abutment interface of external hexagon (eH) implants and abutments with different amounts of bacteria and tightening torques. A bacterial suspension was prepared to inoculate the implants. The first phase of this study used nine EH implants and abutments that were divided into three groups with different amounts of bacterial suspension (n=3): V0.5: 0.5 µL; V1.0: 1.0 µL e V1.5: 1.5 µL, and tightened to the manufacturer's recommended torque. The second phase of this experiment used 27 assemblies that were similar to those used in the first phase. These samples were inoculated with 0.5 µL of bacterial suspension and divided into three groups (n=9). T10: 10 Ncm; T20: 20 Ncm and T32: 32 Ncm. The samples were evaluated according to the turbidity of the broth every 24 hours for 14 days, and the bacteria viability was tested after that period. The statistical evaluation was conducted by Kruskal-Wallis testing (p<.05). During the first phase, groups V1.0 and V1.5 was presented with bacterial contamination in all samples after 24 h. During the second phase, two samples from group T10 and one from T20 presented positive results for bacterial contamination. Different amounts of bacterial solution led to overflow and contamination during the first 24 h of the experiment. The tightening torques did not statistically affect the microleakage in the assemblies. However, the group that was tightened to 32 Ncm torque did not show any bacterial contamination. After 14 days of experimentation, the bacteria were proven to remain viable inside the implant internal cavity.

11 June 2014 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
BSBruno Salles Sotto‐Maior
Bruno Salles Sotto‐Maior
PSPlinio Senna
Plinio Senna
JNJoão Paulo Da Silva Neto
João Paulo Da Silva Neto
MNMauro Antônio de Arruda Nóbilo
Mauro Antônio de Arruda Nóbilo
ACAltair Antoninha Del Bel Cury
Altair Antoninha Del Bel Cury

25 October 2012 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
ADAntônio R.C. Duarte Dds
Antônio R.C. Duarte Dds
JNJoão Paulo Da Silva Neto
João Paulo Da Silva Neto
Júlio C. M. SouzaJúlio C. M. Souza
Júlio C. M. Souza
WBWellington C. Bonachela
Wellington C. Bonachela