Titanium and its alloys are commonly used to fabricate orthopedic implants due to their excellent mechanical properties, corrosion resistance, and biocompatibility. In recent years, orthopedic implant surgeries have considerably increased. This has also resulted in an increase in infection-associated revision surgeries for these implants. To combat this, various approaches are being investigated in the literature. One of the approaches is modifying the surface topography of implants and creating surfaces that are not only antifouling but also encourage osteointegration. Titania nanotube surfaces have demonstrated a moderate decrease in bacterial adhesion while encouraging mesenchymal stem cell adhesion, proliferation, and differentiation, and hence were used in this study. In this work, titania nanotube surfaces were fabricated using a simple anodization technique. These surfaces were further modified with copper using a physical vapor deposition technique, since copper is known to be potent against bacteria once in contact. In this study, scanning electron microscopy was used to evaluate surface topography; energy-dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy were used to evaluate surface chemistry; contact angle goniometry was used to evaluate surface wettability; and X-ray diffraction was used to evaluate surface crystallinity. Antifouling behavior against a gram-positive and a gram-negative bacterium was also investigated. The results indicate that copper-modified titania nanotube surfaces display enhanced antifouling behavior when compared to other surfaces, and this may be a potential way to prevent infection in orthopedic implants.
27 February 2025 in ACS Biomaterials Science & Engineering
This study explores the synergistic effects of combining titania nanotubes (TiNTs) with the biopolymer Tanfloc (TAN) to enhance the surface properties of TiNTs for biomedical applications. We investigated the interactions of blood components and human adipose-derived stem cells (ADSCs) with TiNT surfaces covalently functionalized with Tanfloc (TAN), an aminolyzed polyphenolic tannin derivative. The functionalized surfaces (TiNT-TAN) have great potential to control protein adsorption and platelet adhesion and activation. Fluorescence and scanning electron microscopy (SEM) were used to analyze platelet adherence and activation. The amphoteric nature and multiple functional groups on TAN can control blood protein adsorption, platelet adhesion, and activation. Further, the modified surface supports adipose-derived stem cell (ADSC) viability, attachment, and growth without any cytotoxic effect. The TAN conjugation significantly (****p < 0.0001) increased the proliferation rate of ADSCs compared to the TiNT surfaces.
Titanium and its alloys have been the material of choice for orthopedic implants due to their excellent physical properties as well as biocompatibility. However, titanium is not able to integrate with bone due to the mismatch of mechanical properties. Additionally, bone has a micro–nano hierarchy, which is absent on titanium’s surface. A potential solution to the former is to make the surfaces porous to bring the mechanical properties closer to that of the bone, and a solution for the latter is to fabricate nanostructures. In this study, micro-porous titanium surfaces were hydrothermally treated using an alkali medium to fabricate nanostructures on the existing micro-porosity of the surface. The surface properties were evaluated using scanning electron microscopy, X-ray photoelectron spectroscopy, X-ray diffraction, and nanoindentation. The anti-bacterial properties of the surfaces were evaluated against Gram-positive and Gram-negative bacteria using fluorescence microscopy and scanning electron microscopy. Blood clotting is shown to improve the surface-to-bone integration; hence, whole blood clotting and platelet adhesion and activation were evaluated using a whole blood clotting assay, fluorescence microscopy, and scanning electron microscopy. The results indicate that nanostructured micro-porous titanium surfaces display significantly enhanced anti-bacterial properties as well as equivalent blood clotting characteristics compared to non-porous titanium surfaces.
Ensuring effective integration between the material of an implant and bone is critical to orthopedic implants’ success in the long term. A major issue with dense materials is the mechanical mismatch between them and the bone, which leads to improper osseointegration. Porous implants have presented a solution to this issue as they are able to retain material properties in addition to decreasing mismatches. In order to make implants more biomimetic and to match the micro-/nano hierarchy of bone, several surface modifications have been explored in the literature. Hydrothermal treatment in an alkali media on dense titanium has demonstrated higher differentiation of adipose-derived stem cells to osteogenic lineages. In this study, we fabricated nanostructures using hydrothermal treatment in an alkali medium on micro-porous titanium surfaces and evaluated the adhesion, proliferation, and differentiation of adipose derived stem cells to osteoblasts. The nanostructured-micro-porous titanium surfaces displayed enhanced osteogenic differentiation of adipose derived stem cells. Therefore, they have the potential to be used as surfaces for the fabrication of orthopedic implants.
In the present work, titania nanotubes are fabricated and modified with copper which led to enhanced osteogenic differentiation for adipose derived stem cells.