Effective natural-convection-cooled heat sinks are vital to the future of electronics cooling due to their low energy demand in the absence of an external pumping agency in comparison to other cooling methods. The present numerical study was carried out with ANSYS Fluent and aimed at identifying a more-effective fin design for enhancing heat transfer in natural convection applications for a fixed base-plate size of 100 mm × 100 mm under an applied heat flux of 4000 W/m2. The Rayleigh number used in the present study lied within the range of 2.6 × 106 to 4.5 × 106. Initially, a baseline case with rectangular fins was considered in the present study, and it was optimized with respect to fin spacing. This optimized baseline case was then validated against the semi-empirical correlation from the scientific literature. Upon good agreement, the validated model was used for comparative analysis of different heat sink configurations with rectangular, trapezoidal, curved, and angled fins by constraining the surface area of the heat transfer. The optimized fin spacing obtained for the baseline case was also used for the other heat sink configurations, and then, the fin designs were further optimized for better performance. However, for the angled fin case, the optimized configuration found in the scientific literature was adopted in the present study. The proposed novel curved fin design with a shroud showed a 4.1% decrease in the system’s thermal resistance with an increase in the heat transfer coefficient of 4.4% when compared to the optimized baseline fin case. The obtained results were further non-dimensionalized with the proposed scaling in terms of the baseline case for the two novel heat sink cases (trapezoidal, curved).


27 July 2022 in Combustion Science and Technology
Verified
Journal Article
Closed access
SASyed Mughees Ali
Syed Mughees Ali
VSVarunkumar S
Varunkumar S
A systematic survey of chemical kinetic mechanisms (both simplified and global) shows an absence of a robust kinetic mechanism that can accurately predict characteristics of syngas-air nonpremixed flames. In this work, a three-step global kinetics mechanism is proposed for predicting the extinction strain rate (a(g) ) of syngas-air nonpremixed flames. The available experimental a(g) data-set from the Tsuji type burner was used to evaluate the performance of six syngas kinetics models (four simplified and two global). For this, 2D-planar computations were performed to obtain a(g) values using four CO/H-2 ratios (1, 3, 5, and 29). The results showed that all the simplified kinetics mechanisms overpredicted the a(g) values in the range of 16-224% for the four CO/H-2 ratios. In the case of the global kinetics models namely, CFFR and WO, except for CO/H-2 ratio of 29, CFFR underpredicted a(g) values by 22-55%. WO underpredicted a(g) by 10-44% for CO/H-2 = 1 and overpredicted a(g) by 19-58% for CO/H-2 = 3 and 5. For CO/H-2 = 29, WO overpredicted a(g) values by 151-205%. For CO/H-2 = 1, WO underpredicted a(g) due to two reasons, (1) double accounting of CO hydroxyl oxidation path and, (2) suppression of H-2 oxidation pathways in four-step global JL mechanism, a source for the construction of WO mechanism. From the overall perceptive, WO has performed better compared to other mechanisms. Hence, WO was chosen for further optimization using experimental a(g) data as a target. Sensitivity analysis in terms of a(g) and maximum flame temperature (T-F ) was performed for WO using two CO/H-2 ratios (1 and 5). It was found that for CO/H-2 = 1 and 5, a(g) is most sensitive to Rxn1 (H-2 + 0.5O(2)<-> H2O) and Rxn2 (CO + 0.5O(2) -> CO2). Results from sensitivity analysis, 0D (PSR) computations, and 2D computations have shown that the improper quantification of CO and H-2 oxidation pathways leads to inaccurate a(g) prediction by the WO model. Based on these new insights, a modified three-step WO syngas kinetics model (WO-Opt) is proposed for predicting the extinction strain rate of syngas-air nonpremixed flames. The WO-Opt model was validated against a(g) experimental data. Compared to the WO model, a(g) predictions obtained from the modified WO-Opt model were in good agreement with the syngas-air nonpremixed flames experiments.

29 November 2024 in Fluids
Verified
Journal Article
Open access
PDF file
NGNing Gao
Ning Gao
SASyed Mughees Ali
Syed Mughees Ali
TPTim Persoons
Tim Persoons
Two-phase evaporative spray cooling technology can significantly reduce power consumption in data centre cooling applications. However, the literature lacks an established methodology for assessing the overall performance of such evaporation systems in terms of the water-energy nexus. The current study develops a Lagrangian–Eulerian computational fluid dynamics (CFD) modelling approach to examine the functionality of these two-phase evaporative spray cooling systems. To replicate a modular system, a hollow spray cone nozzle with Rosin–Rammler droplet size distribution is simulated in a turbulent convective natural-air environment. The model was validated against the available experimental data from the literature. Parametric studies on geometric, flow, and climatic conditions, namely, domain length, droplet size, water mass flow rate, temperature, and humidity, were performed. The findings indicate that at elevated temperatures and low humidity, evaporation results in a bulk temperature reduction of up to 12 °C. A specific focus on the climatic conditions of Dublin, Ireland, was used as an example to optimize the evaporative system. A new formulation for the coefficient of performance (COP) is established to assess the performance of the system. Results showed that doubling the injector water mass flow rate improved the evaporated mass flow rate by 188% but reduced the evaporation percentage by 28%, thus reducing the COP. Doubling the domain length improved the temperature drop by 175% and increased the relative humidity by 160%, thus improving the COP. The COP of the evaporation system showed a systematic improvement with a reduction in the droplet size and the mass flow rate for a fixed domain length. The evaporated system COP improves by two orders of magnitude (~90 to 9500) with the reduction in spray Sauter mean diameter (SMD) from 292 μm to 8–15 μm. Under this reduction, close to 100% evaporation rate was achieved in comparison to only a 1% evaporation rate for the largest SMD. It was concluded that the utilization of a fine droplet spray nozzle provides an effective solution for the reduction in water consumption (97% in our case) for data centres, whilst concomitantly augmenting the proportion of evaporation.

28 October 2024 in Fluids
Verified
Journal Article
Open access
PDF file
LDLouis Dewilde
Louis Dewilde
SASyed Mughees Ali
Syed Mughees Ali
Rajesh NimmagaddaRajesh Nimmagadda
Rajesh Nimmagadda
TPTim Persoons
Tim Persoons
Many designs for natural-convection heat sinks and semi-empirical correlations have been proposed in the recent years, but they are only valid in a limited range of Elenbaas numbers El and were mostly tested for laminar flows. To alleviate those limits, parametric studies with 2D and quasi-3D models were carried out, in ranges of Grashof numbers up to 1.55×1011 and Elenbaas numbers up to 3.42×107. Ansys Fluent’s laminar, transition-SST, SST k-ω and k-ϵ models were applied. In addition, when used in this valid range, i.e., mean Elenbaas numbers, with the simplified quasi-3D model, the transition-SST model could predict better results, overestimating the heat flux by 10 to 15% compared to semi-empirical correlations. The 2D model was not deemed satisfying, regarding turbulence models. Consequently, a quasi-3D model was developed: it appeared to be an efficient trade-off between computational time and prediction accuracy, in particular for turbulence models. New grouping factors were also found, to ensure proper dimensioning of natural-convection heat sinks. They corresponded to non-dimensional parameters that dictated the physical behaviour of the heat sink with respect to the semi-empirical correlations. Typically, the ratio of the spacing to the optimal spacing predicted by Bar-Cohen’s correlation turned out to be an appropriate grouping factor with a threshold of 1, above which the fins could safely be considered as isolated, thus greatly simplifying all further calculations.

7 October 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
LDLouis Dewilde
Louis Dewilde
SASyed Mughees Ali
Syed Mughees Ali
Rajesh NimmagaddaRajesh Nimmagadda
Rajesh Nimmagadda
TPTim Persoons
Tim Persoons
Many designs for natural convection heat sinks, and semi-empirical correlations have been proposed in the recent years, but they are only valid in a limited range of Elenbaas number $El$ and were mostly tested for laminar flows. To alleviate those limits, parametric studies with 2D and quasi-3D models were carried out with ranges of Grashof numbers up to $1.55 \cdot 10^{11}$ and Elenbaas numbers up to $3.42 \cdot 10^7$. Ansys Fluent’s laminar, transition-SST, SST k-$\omega$, and k-$\epsilon$ models were applied. In addition, when used in this valid range, \textit{i.e.} mean Elenbaas numbers, with the simplified quasi-3D model, the transition-SST model can predict better results, over-estimating the heat flux by $10$ to $15\%$ compared to semi-empirical correlations. The 2D model was not deemed satisfying regarding turbulence models. Consequently, a quasi-3D model was developed: it appeared to be an efficient trade-off between computational time and prediction accuracy, in particular for turbulence models. New grouping factors were also found, to ensure proper dimensioning of natural convection heat sinks. They correspond to non-dimensional parameters that dictate the physical behaviour of the heat sink with respect to the semi-empirical correlations. Typically, the ratio of the spacing to the optimal spacing predicted by Bar-Cohen's correlation turned out to be an appropriate grouping factor with a threshold of $1$, above which the fins could safely be considered as isolated, thus greatly simplifying all further calculations.