Nafiseh Fahimi-Kashani

Dr. Nafiseh Fahimi-Kashani


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2022 in Analytica Chimica Acta
Verified
Journal Article
Closed access
FGForough Ghasemi
Forough Ghasemi
Nafiseh Fahimi-KashaniNafiseh Fahimi-Kashani
Nafiseh Fahimi-Kashani
ABArafeh Bigdeli
Arafeh Bigdeli
AAAzad H. Alshatteri
Azad H. Alshatteri
SASamira Abbasi-Moayed
Samira Abbasi-Moayed
MHMohammad Reza Hormozi-Nezhad
Mohammad Reza Hormozi-Nezhad

31 January 2023 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
MHM. Hassani-Marand
M. Hassani-Marand
Nafiseh Fahimi-KashaniNafiseh Fahimi-Kashani
Nafiseh Fahimi-Kashani
MHMohammad Reza Hormozi-Nezhad
Mohammad Reza Hormozi-Nezhad
Catecholamine neurotransmitters (CNs), such as dopamine (DA), epinephrine (EP), norepinephrine (NEP), and levodopa (LD), are recognized as the primary biomarkers of a variety of neurological illnesses. Therefore, simultaneous monitoring of these biomarkers is highly recommended for clinical diagnosis and treatment. In this study, a high-performance colorimetric artificial tongue has been proposed for the multiplex detection of CNs. Different aggregation behaviors of gold nanoparticles in the presence of CNs under various buffering conditions generate unique fingerprint response patterns. Under various buffering conditions, the distinct acidity constants of CNs, and consequently their predominant species at a given pH, drive the aggregation of gold nanoparticles (AuNPs). The utilization of machine learning algorithms in this design enables classification and quantification of CNs in various samples. The response profile of the array was analyzed using the linear discriminant analysis algorithm for classification of CNs. This colorimetric sensor array is capable of accurately distinguishing between individual neurotransmitters and their combinations. Partial least squares regression was also applied for quantitation purposes. The obtained analytical figures of merit (FOMs) and linear ranges of 0.6–9 μM (R2 = 0.99) for DA, 0.1–10 μM (R2 = 0.99) for EP, 0.1–9 μM (R2 = 0.99) for NEP and 1–70 μM (R2 = 0.99) for LD demonstrated the potential applicability of the developed sensor array in precise and accurate determination of CNs. Finally, the feasibility of the array was validated in human urine samples as a complex biological fluid with LODs of 0.3, 0.5, 0.2, and 1.9 μM for DA, EP, NEP, and LD, respectively.

16 September 2022 in Analytica Chimica Acta
Verified
Journal Article
Closed access
ZIZahra Jafar-Nezhad Ivrigh
Zahra Jafar-Nezhad Ivrigh
Nafiseh Fahimi-KashaniNafiseh Fahimi-Kashani
Nafiseh Fahimi-Kashani
RMRazieh Morad
Razieh Morad
ZJZahar Jamshidi
Zahar Jamshidi
MHMohammad Reza Hormozi-Nezhad
Mohammad Reza Hormozi-Nezhad

4 September 2023 in Talanta
Verified
Journal Article
Closed access
MHM. Hassannia
M. Hassannia
Nafiseh Fahimi-KashaniNafiseh Fahimi-Kashani
Nafiseh Fahimi-Kashani
MHMohammad Reza Hormozi-Nezhad
Mohammad Reza Hormozi-Nezhad

1 April 2024
Verified
Journal Article
Open access
ZMZahra Mousavian
Zahra Mousavian
EFEnsieh Fahimi-Kashani
Ensieh Fahimi-Kashani
VNVahidreza Nafisi
Vahidreza Nafisi
Nafiseh Fahimi-KashaniNafiseh Fahimi-Kashani
Nafiseh Fahimi-Kashani
Background: The early detection of infectious microorganisms is crucial for preventing and controlling the transmission of diseases. This article provides a comprehensive review of biosensors based on various diagnostic methods for measuring airborne pathogens. Objective: This article aims to explore recent advancements in the field of biosensors tailored for the detection and monitoring of airborne microorganisms, offering insights into emerging technologies and their potential applications in environmental surveillance and public health management. Materials and Methods: The study summarizes the research conducted on novel methods of detecting airborne microorganisms using different biological sensors, as well as the application of signal amplification technologies such as polymerase chain reaction (PCR), immunoassay reactions, molecular imprinted polymers (MIP) technique, lectin and cascade reactions, and nanomaterials. Results: Antibody and PCR detection methods are effective for specific microbial strains, but they have limitations including limited stability, high cost, and the need for skilled operators with basic knowledge of the target structure. Biosensors based on MIP and lectin offer a low-cost, stable, sensitive, and selective alternative to antibodies and PCR. However, challenges remain, such as the detection of small gas molecules by MIP and the lower sensitivity of lectins compared to antibodies. Additionally, achieving high sensitivity in complex environments poses difficulties for both methods. Conclusion: The development of sensitive, reliable, accessible, portable, and inexpensive biosensors holds great potential for clinical and environmental applications, including disease diagnosis, treatment monitoring, and point -of -care testing, offering a promising future in this field. This review presents an overview of biosensor detection principles, covering component identification, energy conversion principles, and signal amplification. Additionally, it summarizes the research and applications of biosensors in the detection of airborne microorganisms. The latest advancements and future trends in biosensor detection of airborne microorganisms are also analyzed.

16 November 2024 in Microchemical Journal
Verified
Journal Article
Closed access
ZFZ. Feyzollahi
Z. Feyzollahi
Nafiseh Fahimi-KashaniNafiseh Fahimi-Kashani
Nafiseh Fahimi-Kashani
MHMohammad Reza Hormozi-Nezhad
Mohammad Reza Hormozi-Nezhad