Vahidreza Nafisi

Dr. Vahidreza Nafisi


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
VNVahidreza Nafisi
Vahidreza Nafisi
MSMina Shahabi
Mina Shahabi

19 January 2022 in BioMed Research International
Verified
Journal Article
Open access
PDF file
MBM. R. Asghari Bejestani
M. R. Asghari Bejestani
GKGholam Reza Mohammad Khani
Gholam Reza Mohammad Khani
VNVahidreza Nafisi
Vahidreza Nafisi
FDF. Darakeh
F. Darakeh
This study focuses on providing a simple, extensible, and multiclass classifier for imagined words using EEG signals. Six Persian words, along with the silence (or idle state), were selected as input classes. The words can be used to control a mouse/robot movement or fill a simple computer form. The data set of this study was 10 recordings of five participants collected in five sessions. Each record had 20 repetitions of all words and the silence. Feature sets consist of normalized, 1 Hz resolution frequency spectrum of 19 EEG channels in 1 to 32 Hz bands. Majority rule on a bank of binary SVM classifiers was used to determine the corresponding class of a feature set. Mean accuracy and confusion matrix of the classifiers were estimated by Monte‐Carlo cross‐validation. According to recording the time difference of inter‐ and intraclass samples, three classification modes were defined. In the long‐time mode, where all instances of a word in the whole database are involved, average accuracies were about 58% for Word‐Silence, 60% for Word‐Word, 40% for Word‐Word‐Silence, and 32% for the seven‐class classification (6 Words+Silence). For the short‐time mode, when only instances of the same record are used, the accuracies were 96, 75, 79, and 55%, respectively. Finally, in the mixed‐time classification, where samples of every class are taken from a different record, the highest performance achieved with average accuracies was about 97, 97, 92, and 62%. These results, even in the worst case of the long‐time mode, are meaningfully better than random and are comparable with the best reported results of previously conducted studies in this area.

1 January 2022 in Journal of Medical Signals & Sensors
Verified
Journal Article
Open access
PDF file
VNVahidreza Nafisi
Vahidreza Nafisi
RGRoshanak Ghods
Roshanak Ghods
Background: Temperament (Mizaj) determination is an important stage of diagnosis in Persian Medicine. This study aimed to evaluate thermal imaging as a reliable tool that can be used instead of subjective assessments. Methods: The temperament of 34 participants was assessed by a PM specialist using standardized Mojahedi Mizaj Questionnaire (MMQ) and thermal images of the wrist in the supine position, the back of the hand, and their whole face under supervision of the physician were recorded. Thirteen thermal features were extracted and a classifying algorithm was designed based on the genetic algorithm and Adaboost classifier in reference to the temperament questionnaire. Results: The results showed that the mean temperature and temperature variations in the thermal images were relatively consistent with the results of MMQ. Among the three body regions, the results related to the image from Malmas were most consistent with MMQ. By selecting six of the 13 features that had the most impact on the classification, the accuracy of 94.7 ± 13.0, sensitivity of 95.7 ± 11.3, and specificity of 98.2 ± 4.2 were obtained. Conclusions: The thermal imaging was relatively consistent with standardized MMQ and can be used as a reliable tool for evaluating warm/cold temperament. However, the results reveal that thermal imaging features may not be only main features for temperament classification and for more reliable classification, it needs to add some different features such as wrist pulse features and some subjective characteristics.

1 April 2024
Verified
Journal Article
Open access
ZMZahra Mousavian
Zahra Mousavian
EFEnsieh Fahimi-Kashani
Ensieh Fahimi-Kashani
VNVahidreza Nafisi
Vahidreza Nafisi
Nafiseh Fahimi-KashaniNafiseh Fahimi-Kashani
Nafiseh Fahimi-Kashani
Background: The early detection of infectious microorganisms is crucial for preventing and controlling the transmission of diseases. This article provides a comprehensive review of biosensors based on various diagnostic methods for measuring airborne pathogens. Objective: This article aims to explore recent advancements in the field of biosensors tailored for the detection and monitoring of airborne microorganisms, offering insights into emerging technologies and their potential applications in environmental surveillance and public health management. Materials and Methods: The study summarizes the research conducted on novel methods of detecting airborne microorganisms using different biological sensors, as well as the application of signal amplification technologies such as polymerase chain reaction (PCR), immunoassay reactions, molecular imprinted polymers (MIP) technique, lectin and cascade reactions, and nanomaterials. Results: Antibody and PCR detection methods are effective for specific microbial strains, but they have limitations including limited stability, high cost, and the need for skilled operators with basic knowledge of the target structure. Biosensors based on MIP and lectin offer a low-cost, stable, sensitive, and selective alternative to antibodies and PCR. However, challenges remain, such as the detection of small gas molecules by MIP and the lower sensitivity of lectins compared to antibodies. Additionally, achieving high sensitivity in complex environments poses difficulties for both methods. Conclusion: The development of sensitive, reliable, accessible, portable, and inexpensive biosensors holds great potential for clinical and environmental applications, including disease diagnosis, treatment monitoring, and point -of -care testing, offering a promising future in this field. This review presents an overview of biosensor detection principles, covering component identification, energy conversion principles, and signal amplification. Additionally, it summarizes the research and applications of biosensors in the detection of airborne microorganisms. The latest advancements and future trends in biosensor detection of airborne microorganisms are also analyzed.

1 January 2011 in Journal of Medical Signals & Sensors
Verified
Journal Article
Open access
PDF file
VNVahidreza Nafisi
Vahidreza Nafisi
MEManouchehr Eghbal
Manouchehr Eghbal
MMMohammad Reza Jahed Motlagh
Mohammad Reza Jahed Motlagh
FYFatemeh Yavari
Fatemeh Yavari
Fuzzy controllers are being used in various control schemes. The aim of this study is to adjust the hemodialysis machine parameters by utilizing a fuzzy logic controller (FLC) so that patient's hemodynamic condition remains stable during hemodialysis treatment. For this purpose, a comprehensive mathematical model of the arterial pressure response during hemodialysis, including hemodynamic, osmotic, and regulatory phenomena has been used. The multi-input multi-output (MIMO) fuzzy logic controller receives three parameters from the model (heart rate, arterial blood pressure, and relative blood volume) as input. According to the changes in the controller input values and its rule base, the outputs change so that the patient's hemodynamic condition remains stable. The results of the simulations illustrate that applying the controller can improve the stability of a patient's hemodynamic condition during hemodialysis treatment and it also decreases the treatment time. Furthermore, by using fuzzy logic, there is no need to have prior knowledge about the system under control and the FLC is compatible with different patients.

1 January 2012 in Journal of Medical Signals & Sensors
Verified
Journal Article
Open access
PDF file
MAMohammad Ali Ardekani
Mohammad Ali Ardekani
VNVahidreza Nafisi
Vahidreza Nafisi
FFFoad Farhani
Foad Farhani
Hot-wire spirometer is a kind of constant temperature anemometer (CTA). The working principle of CTA, used for the measurement of fluid velocity and flow turbulence, is based on convective heat transfer from a hot-wire sensor to a fluid being measured. The calibration curve of a CTA is nonlinear and cannot be easily extrapolated beyond its calibration range. Therefore, a method for extrapolation of CTA calibration curve will be of great practical application. In this paper, a novel approach based on the conventional neural network and self-organizing map (SOM) method has been proposed to extrapolate CTA calibration curve for measurement of velocity in the range 0.7-30 m/seconds. Results show that, using this approach for the extrapolation of the CTA calibration curve beyond its upper limit, the standard deviation is about −0.5%, which is acceptable in most cases. Moreover, this approach for the extrapolation of the CTA calibration curve below its lower limit produces standard deviation of about 4.5%, which is acceptable in spirometry applications. Finally, the standard deviation on the whole measurement range (0.7-30 m/s) is about 1.5%.