Philippe A. Passeraub

Dr. Philippe A. Passeraub

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2013 in Molecules
Verified
Journal Article
Open access
PDF file
Denis PrimDenis Prim
Denis Prim
FRFabien Rebeaud
Fabien Rebeaud
VCVincent Cosandey
Vincent Cosandey
RMRoger Marti
Roger Marti
PPPhilippe A. Passeraub
Philippe A. Passeraub
MPMarc Pfeifer
Marc Pfeifer
Several azide-derivatized and fluorescently-labeled peptides were immobilized on azadibenzocyclooctyne (ADIBO)-activated slide surfaces via a strain-promoted alkyne-azide cycloaddition (SPAAC) reaction revealing excellent immobilization kinetics, good spot homogeneities and reproducible fluorescence signal intensities. A myc-peptide micro-array immunoassay showed an antibody limit-of-detection (LOD) superior to a microtiter plate-based ELISA. Bovine serum albumin (BSA) and dextran covalently attached via “click” chemistry more efficiently reduced non-specific binding (NSB) of fluorescently-labeled IgG to the microarray surface in comparison to immobilized hexanoic acid and various types of polyethylene glycol (PEG) derivatives. Confirmation of these findings via further studies with other proteins and serum components could open up new possibilities for human sample and microarray platform-based molecular diagnostic tests.

1 June 2003 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
PPPhilippe A. Passeraub
Philippe A. Passeraub
AAAntonio-Carlos Almeida
Antonio-Carlos Almeida
NTNitish Thakor
Nitish Thakor

16 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
SSSpyridon Schoinas
Spyridon Schoinas
AGAdyl-Michaël El Guamra
Adyl-Michaël El Guamra
FMFabien Moreillon
Fabien Moreillon
PPPhilippe A. Passeraub
Philippe A. Passeraub
This paper presents the fabrication and characterization of a flexible, flat, miniaturized fluxgate sensor with a thin amorphous rectangular magnetic core fabricated by the pad/printing technique. Both the design and the various printing steps of the sensor are presented. The fluxgate sensor comprises of solenoid coils, and to the best of our knowledge, is the first to be printed with a conventional micro-printing technique. The magnetic core is a non-printed component, placed between the printed layers. The sensor’s linear measuring range is ±40 µT with 2% full-scale linearity error, at 100 kHz excitation frequency. The highest measured sensitivity reaches 14,620 V/T at 200 kHz, while the noise of the sensor was found to be 10 nT/ Hz at 1 Hz.

1 August 1999 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
PPPhilippe A. Passeraub
Philippe A. Passeraub
PBP.-A. Besse
P.-A. Besse
ABA. Bayadroun
A. Bayadroun
SHS. Hediger
S. Hediger
EBE. Bernasconi
E. Bernasconi
RPR.S. Popovic
R.S. Popovic

28 February 1997 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
PPPhilippe A. Passeraub
Philippe A. Passeraub
PBPierre-André Besse
Pierre-André Besse
CRChristina de Raad
Christina de Raad
RPRade S Popovic
Rade S Popovic

13 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AJAhmad Jaafar
Ahmad Jaafar
SSSpyridon Schoinas
Spyridon Schoinas
PPPhilippe A. Passeraub
Philippe A. Passeraub
The purpose of this paper is to present a newly developed process for the fabrication of multilayer circuits based on the pad-printing technique. Even though the maturity level, in terms of accuracy, substrate type and print size of several printing industrial processes is relatively high, the fabrication complexity of multilayer printed electronics remains relatively high. Due to its versatility, the pad-printing technique allows the superposition of printed conductive and insulating layers. Compared to other printing processes, its main advantage is the ability to print on various substrates even on flexible, curved or irregular surfaces. Silver-based inks were used for the formulation of conductive layers while UV inks were employed to fulfil the functionality of the insulating layers. To demonstrate the functionality of the pad-printing results, a multilayer test pattern has been designed and printed on Kapton®. Furthermore, to demonstrate the efficacy of this approach, a multilayer circuit composed of three stacked layers has been designed and printed on various substrates including Kapton®, paper and wood. This electronic circuit controls an array of LEDs through the manipulation of a two-key capacitive touch sensor. This study, allowed us to define recommendations for the different parameters leading to high printing quality. We expect a long-term beneficial impact of this study towards a low-cost, fast, and environmental-friendly production of printed electronics.