Marc Pfeifer

Prof. Marc Pfeifer

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2020 in The Journal of Applied Laboratory Medicine
Verified
Journal Article
Open access
PDF file
ATAdriano Taddeo
Adriano Taddeo
Denis PrimDenis Prim
Denis Prim
EBElena-Diana Bojescu
Elena-Diana Bojescu
JSJean-Manuel Segura
Jean-Manuel Segura
MPMarc Pfeifer
Marc Pfeifer
Background: Immunosuppressive drugs (ISD) are an essential tool in the treatment of transplant rejection and immune-mediated diseases. Therapeutic drug monitoring (TDM) for determination of ISD concentrations in biological samples is an important instrument for dose personalization for improving efficacy while reducing side effects. While currently ISD concentration measurements are performed at specialized, centralized facilities, making the process complex and laborious for the patient, various innovative technical solutions have recently been proposed for bringing TDM to the point-of-care (POC). Content: In this review, we evaluate current ISD-TDM and its value, limitations, and proposed implementations. Then, we discuss the potential of POC-TDM in the era of personalized medicine, and provide an updated review on the unmet needs and available technological solutions for the development of POC-TDM devices for ISD monitoring. Finally, we provide concrete suggestions for the generation of a meaningful and more patient-centric process for ISD monitoring. Summary: POC-based ISD monitoring may improve clinical care by reducing turnaround time, by enabling more frequent measurements in order to obtain meaningful pharmacokinetic data (i.e., area under the curve) faster reaction in case of problems and by increasing patient convenience and compliance. The analysis of the ISD-TDM field prompts the evolution of POC testing toward the development of fully integrated platforms able to support clinical decision-making. We identify 4 major areas requiring careful combined implementation: patient usability, data meaningfulness, clinicians’ acceptance, and cost-effectiveness.

16 August 2013 in Molecules
Verified
Journal Article
Open access
PDF file
Denis PrimDenis Prim
Denis Prim
FRFabien Rebeaud
Fabien Rebeaud
VCVincent Cosandey
Vincent Cosandey
RMRoger Marti
Roger Marti
PPPhilippe A. Passeraub
Philippe A. Passeraub
MPMarc Pfeifer
Marc Pfeifer
Several azide-derivatized and fluorescently-labeled peptides were immobilized on azadibenzocyclooctyne (ADIBO)-activated slide surfaces via a strain-promoted alkyne-azide cycloaddition (SPAAC) reaction revealing excellent immobilization kinetics, good spot homogeneities and reproducible fluorescence signal intensities. A myc-peptide micro-array immunoassay showed an antibody limit-of-detection (LOD) superior to a microtiter plate-based ELISA. Bovine serum albumin (BSA) and dextran covalently attached via “click” chemistry more efficiently reduced non-specific binding (NSB) of fluorescently-labeled IgG to the microarray surface in comparison to immobilized hexanoic acid and various types of polyethylene glycol (PEG) derivatives. Confirmation of these findings via further studies with other proteins and serum components could open up new possibilities for human sample and microarray platform-based molecular diagnostic tests.

11 March 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Milica JovicMilica Jovic
Milica Jovic
Denis PrimDenis Prim
Denis Prim
Edis SainiEdis Saini
Edis Saini
MPMarc Pfeifer
Marc Pfeifer
Globally, 70 million people are annually affected by TBI. A significant proportion of all TBI cases are actually mild TBI (concussion, 70–85%), which is considerably more difficult to diagnose due to the absence of apparent symptoms. Current clinical practice of diagnosing mTBI largely resides on the patients’ history, clinical aspects, and CT and MRI neuroimaging observations. The latter methods are costly, time-consuming, and not amenable for decentralized or accident site measurements. As an alternative (and/or complementary), mTBI diagnostics can be performed by detection of mTBI biomarkers from patients’ blood. Herein, we proposed two strategies for the detection of three mTBI-relevant biomarkers (GFAP, h-FABP, and S100β), in standard solutions and in human serum samples by using an electrochemiluminescence (ECL) immunoassay on (i) a commercial ECL platform in 96-well plate format, and (ii) a “POC-friendly” platform with disposable screen-printed carbon electrodes (SPCE) and a portable ECL reader. We further demonstrated a proof-of-concept for integrating three individually developed mTBI assays (“singleplex”) into a three-plex (“multiplex”) assay on a single SPCE using a spatially resolved ECL approach. The presented methodology demonstrates feasibility and a first step towards the development of a rapid POC multiplex diagnostic system for the detection of a mTBI biomarker panel on a single SPCE.

12 May 2021 in RSC Advances
Verified
Journal Article
Open access
PDF file
NPNadezda Pankratova
Nadezda Pankratova
Milica JovicMilica Jovic
Milica Jovic
MPMarc Pfeifer
Marc Pfeifer
Traumatic Brain Injury (TBI) being one of the principal causes of death and acquired disability in the world imposes a large burden on the global economy. Mild TBI (mTBI) is particularly challenging to assess due to the frequent lack of well-pronounced post-injury symptoms. However, if left untreated mTBI (especially when repetitive) can lead to serious long-term implications such as cognitive and neuropathological disorders. Computer tomography and magnetic resonance imaging commonly used for TBI diagnostics require well-trained personnel, are costly, difficult to adapt for on-site measurements and are not always reliable in identifying small brain lesions. Thus, there is an increasing demand for sensitive point-of-care (POC) testing tools in order to aid mTBI diagnostics and prediction of long-term effects. Biomarker quantification in body fluids is a promising basis for POC measurements, even though establishing a clinically relevant mTBI biomarker panel remains a challenge. Actually, a minimally invasive, rapid and reliable multianalyte detection device would allow the efficient determination of injury biomarker release kinetics and thus support the preclinical evaluation and clinical validation of a proposed biomarker panel for future decentralized in vitro diagnostics. In this respect electrochemical biosensors have recently attracted great attention and the present article provides a critical study on the electrochemical protocols suggested in the literature for detection of mTBI-relevant protein biomarkers. The authors give an overview of the analytical approaches for transduction element functionalization, review recent technological advances and highlight the key challenges remaining in view of an eventual integration of the proposed concepts into POC diagnostic solutions.

8 August 2022 in Analytica Chimica Acta
Verified
Journal Article
Open access
EBE.-Diana Bojescu
E.-Diana Bojescu
Denis PrimDenis Prim
Denis Prim
MPMarc Pfeifer
Marc Pfeifer
JSJean-Manuel Segura
Jean-Manuel Segura
Many therapeutic drugs require monitoring of their concentration in blood followed by dose adjustments in order to ensure efficacy while minimizing adverse effects. It would be highly desirable to perform such measurements rapidly and with reduced sample volumes to support point-of-care testing. Here, we demonstrate that the concentration of small therapeutics can be determined in whole blood within paper-like membranes using Fluorescence Polarization Immunoassay (FPIA). Different types of paper-like materials such as glass microfibers, cellulose and filter paper were investigated for artefacts such as scattering or autofluorescence. Accurate determination of the fluorescence polarization of red-emitting fluorophores at sub-nanomolar concentrations was feasible within glass fiber membranes. This enabled the development of a competitive immunoassay for the quantification of the antibiotic tobramycin using only 1 μL of plasma in glass fiber micro-chambers. Furthermore, the same membrane was used for transversal separation of blood cells followed by accurate FPIA read-out at the bottom part of the micro-chamber. For quantification of tobramycin, 1 μL of whole blood was incubated with the immunoassay reagents during only 3 min before deposition in the micro-chamber and analysis. Within the therapeutic window, coefficients of variation were around 20% and recoveries between 80 and 105%. Owing to the simplified procedure requiring no centrifugation, the reduced blood sample volume and the rapid analysis time, we envision that this novel method supports the performance of therapeutic drug monitoring directly at the point of care.

30 May 2023 in Sensors & Diagnostics
Verified
Journal Article
Open access
PDF file
Milica JovicMilica Jovic
Milica Jovic
Denis PrimDenis Prim
Denis Prim
OROphélie Righini
Ophélie Righini
DTDavid Tagan
David Tagan
MSMélanie Stäuble
Mélanie Stäuble
MPMarc Pfeifer
Marc Pfeifer
Traumatic brain injuries (TBI) are typically acquired when a sudden violent event causes damage to the brain tissue. A high percentage (70–85%) of all TBI patients are suffering from mild TBI (mTBI), which is often difficult to detect and diagnose with standard imaging tools (MRI, CT scan) due to the absence of significant lesions and specific symptoms. Recent studies suggest that a screening test based on the measurement of a protein biomarker panel directly from a patient's blood can facilitate mTBI diagnosis. Herein, we report a novel prototype system designed as a precursor of a future hand-held point-of-care (POC) diagnostic device for the simultaneous multi-biomarker sensing, employing a microarray-type spatially resolved electrochemiluminescence immunoassay (SR-ECLIA). The small tabletop prototype consists of a screen-printed electrode compartment to conduct multi-analyte ECL sandwich assays, a potentiostat module and a light collection module, all integrated into a compact 3D-printed housing (18.2 × 16.5 × 5.0 cm), as well as an sCMOS detector. Based on this design concept, further miniaturization, system integration, performance optimization and clinical evaluation shall pave the way towards the development of a portable instrument for use at the site of accident and healthcare. To demonstrate the system's feasibility, current performance and efficiency, the simultaneous detection of three mTBI biomarkers (GFAP, h-FABP, S100β) in 50% serum was achieved in the upper pg mL−1 range. The proposed device is amenable to the detection of other biomarker panels and thus could open new medical diagnostic avenues for sensitive multi-analyte measurements with low-volume biological sample requirements.