The flexible shaft coupled to the synchronous generator (SG) is critical for the doubly-fed induction generators (DFIG) based wind turbines to improve the ability to suppress system power oscillations. The rigid shaft coupling relationship between the DFIG and SG is analyzed first under the current virtual synchronous generator (VSG) control. To give the power system a vibrational degree of freedom, a novel virtual shaft is added to the VSG emulated by the DFIG-based wind turbine. The power system's two-degree-of-freedom (TDOF) coupled motion model with VSG is then established. The virtual shaft coupling adapted to a DFIG is designed using anti-resonance theory, and the amplitude-frequency characteristic of the TDOF power system is analyzed. With the additional stiffness of the virtual shaft, the power support functions of the VSG, including inertia and damping, are integrated by optimizing the oscillation amplitude at two fixed points in the frequency domain. Finally, on a controller hardware-in-the-loop platform, a typical power system with a high penetration of wind power generation is simulated. The test results demonstrate that by employing virtual shaft coupling, it is possible to suppress system frequency variation and rotor angle oscillation during transient events, significantly improving the reliability of the power support provided by wind turbines.
23 October 2024 in IEEE Transactions on Sustainable Energy
Efficient oscillation energy transfer between grid-forming wind turbine and synchronous generator (SG) is the key to improving the dynamic stability of regional power grid with a high proportion of renewable power generation. This paper first analyzes the elastic coupling relationship between the doubly fed induction generator (DFIG)-based wind turbines and the SGs under the grid-forming control, establishing a two-degrees-of- freedom dynamic system model incorporating grid- forming wind power generation. The root locus method is then applied to analyze the influence of virtual inertia and damping on the system's dynamic stability. Subsequently, the virtual inertia demand of grid-forming wind turbines is obtained based on the constraint of frequency change rate. Moreover, the oscillation energy transfer mechanism between grid-forming wind turbine and SG is further analyzed using the Hamiltonian energy function method. Then, a novel design scheme of the control parameters of the grid-forming DFIG is proposed using the condition for the efficient transfer of oscillation energy between generators. Finally, the proposed control is verified in the New England simulation system and a 9-node power system on the controller hardware-in-the-loop platform with high wind power penetration. The test results demonstrate that the proposed control significantly improves the grid-connected support performance of the DFIG to suppress system power oscillation and frequency change.
14 December 2020 in IEEE Transactions on Power Systems
Transient recovery characteristics of DC voltage are critical to analyze the stability criterion and the fault ride-through capability of voltage source converter (VSC)-based DC power systems. In this paper, the dynamic model of a flexible DC power grid was initially established, and then, the dynamic operation mechanism of the system was presented by analyzing the movement locus of the operating point when disturbances occur in the DC grid. Subsequently, the DC transient voltage limit and the DC fault clearing time were calculated in order to obtain the transient stability criterion of the DC power system. In addition, a novel voltage transient recovery control strategy was proposed by improving the droop control of the DC voltage to extend the transient stability margin of the power system. Finally, a typical multi-terminal flexible DC power grid was developed on a hardware-in-the-loop platform. The results demonstrated that the voltage recovery ability of the DC power system can be quantitatively estimated by the stability criterion, while the system transient stability can be improved by the proposed control strategy.
25 November 2024 in IEEE Transactions on Power Delivery
Efficient power oscillation suppression in broad bandwidth and reduction of self-induced resonance risk are critical for the wide application of the virtual synchronous generator (VSG) in power systems with a high penetration of wind power generation. In this paper, the linear virtual shaft coupling relationship between the VSG emulated by the doubly fed induction generator (DFIG)-based wind turbine and synchronous generator (SG) is analyzed firstly. The two degrees of freedom model of the power system with the VSG is then established under the application of the virtual shaft to connect the generators. A novel virtual shaft with cubic stiffness is then introduced to the reduce the self-induced resonance risk of the VSGs. Using the optimal bandwidth theory, the oscillation suppression bandwidth of the VSG with the nonlinear virtual shaft are extended. To further improve the power support functions of the VSGs, a novel nonlinear virtual shaft control adapted to the DFIG-based wind turbine is proposed, and the design parameters are optimized. Finally, a typical 9-nodes power system with a high wind penetration of 32% is simulated on a controller hardware-in-the-loop platform. The test results demonstrate that the nonlinear virtual shaft reduces the risk of resonances by extending the oscillation suppression bandwidth of the VSG, thus improving the power support ability of wind turbines for system frequency regulation and power oscillation suppression.
This study investigates a novel operating method of the interconnected power grid to improve dynamic stability using variable inertia control of large wind farms. In this scheme, the system inertia is considered as an adjustable operating parameter which can be regulated for inter‐area power oscillation control and frequency support. Based on the linear state equations derived from a two‐area interconnected power system, the effect of the controlled inertia on power oscillation damping is evaluated theoretically considering the different cases of power feeding and receiving networks. The respective wind turbine variable inertia control strategies for the feeding and receiving regional networks are proposed to enhance both inter‐area power oscillation damping and frequency stability. A typical two‐area interconnected power system with a high 30% wind penetration is simulated, which consists of four conventional power plants and two doubly fed induction generator (DFIG)‐based wind farms. The results demonstrate that by using the proposed control scheme, the frequency stability and the inter‐area oscillation damping are both significantly improved for the more effective inertia support in the interconnected power system.
1 January 2025 in IET Generation, Transmission & Distribution
According to the constraints of frequency safety indices, evaluating the inertia and primary frequency regulation demand, rationally utilizing the energy reserve provided by wind turbines and energy storage devices to ensure the safety of the system frequency response, is the key to improve the stability of large‐scale new energy power systems. First, frequency response characteristics and frequency regulation safety indicators required by new energy generation systems were analyzed. Second, the frequency dynamic response model of the system with wind power and energy storage was established, and the extreme value time for the virtual inertia response of the system was calculated. Using the extreme time at which the frequency drop is maximum, the virtual inertia time constant of the wind‐storage system was evaluated. Additionally, the system inertia and the primary frequency regulation demand were obtained considering the frequency safety indices, and a novel coordinated control strategy for wind power and energy storage to provide the required frequency support was proposed. Finally, a grid‐connected wind‐storage simulation system was built to verify the superiority of the proposed control strategy. The obtained results indicate that the proposed control scheme flexibly meets the system frequency safety requirements.