Transient recovery characteristics of DC voltage are critical to analyze the stability criterion and the fault ride-through capability of voltage source converter (VSC)-based DC power systems. In this paper, the dynamic model of a flexible DC power grid was initially established, and then, the dynamic operation mechanism of the system was presented by analyzing the movement locus of the operating point when disturbances occur in the DC grid. Subsequently, the DC transient voltage limit and the DC fault clearing time were calculated in order to obtain the transient stability criterion of the DC power system. In addition, a novel voltage transient recovery control strategy was proposed by improving the droop control of the DC voltage to extend the transient stability margin of the power system. Finally, a typical multi-terminal flexible DC power grid was developed on a hardware-in-the-loop platform. The results demonstrated that the voltage recovery ability of the DC power system can be quantitatively estimated by the stability criterion, while the system transient stability can be improved by the proposed control strategy.
Total hip arthroplasty (THA) is a widely-used surgical intervention for treating patients with end-stage degenerative and inflammatory osteoarthropathy. However, wear particles from the artificial titanium joint can induce osteolysis, limiting the long-term survivorship of THA. Monocyte/macrophage lineage cells are the key players in the response to wear particles, and the proinflammatory NF-κB and phosphoinositide 3-kinase (PI3K)–AKT Ser/Thr kinase (AKT)-signaling pathways have been shown to be the most important contributors to wear particle–induced osteolysis. In contrast, ubiquitin-specific protease 14 (USP14) specifically removes the polyubiquitin chains from the nucleotide-binding and oligomerization domain (NOD)-like receptor family Caspase recruitment domain (CARD)–containing 5 (NLRC5) and thereby enhances the NLRC5-mediated inhibition of NF-κB signaling. In this study, we aimed to clarify the role of the USP14–NLRC5 pathway in wear particle–induced osteolysis in vitro and in vivo. We found that NLRC5 or USP14 overexpression inhibits titanium particle–induced proinflammatory tumor necrosis factor α (TNFα) production and NF-κB pathway activation, and it also decreases M1 macrophage polarization and PI3K/AKT pathway activation. Of note, NLRC5 and USP14 overexpression attenuated titanium particle–induced cranial osteolysis in mice. In conclusion, the findings of our study indicate that the USP14–NLRC5 pathway inhibits titanium particle–induced osteolysis by suppressing the NF-κB and PI3K/AKT pathways both in vitro and in vivo.
Background: The routine radial artery (RA) puncture may fail when anatomical variation of the RA is encountered. Superficial radial artery (SRA) is one of the anatomic variants of the RA, with the incidence of about 1 to 1.5%. Recently, distal transradial access (dTRA) has emerged as a novel approach for coronary catheterization (CC), but performing CC through dTRA in patient with SRA has never been reported. Case presentation: A 57-year-old male was admitted to hospital due to intermittent chest pain for 4 days. He was diagnosed with unstable angina pectoris and planned to receive coronary angiography (CAG). Before the operation, the existence and course of SRA were confirmed by palpation and ultrasonography with color Doppler. We marked the puncture site under the guidance of ultrasonography and successfully performed CC through the dTRA during patient’s hospitalization. Conclusions: As far as we know, this is the first report that presents a case of SRA and percutaneous coronary intervention (PCI) treatment in which was successfully performed through dTRA. It is safe and feasible to perform CC via dTRA in case of SRA, and dTRA seems to be the preferred access.
9 January 2025 in IEEE Transactions on Instrumentation and Measurement
The manufacturing accuracy of freeform surface is limited by its detection accuracy. In this paper, a laser differential confocal freeform surface shape measurement method based on translational motion error monitoring and compensation is proposed. This method realizes helical scanning measurements of a freeform surface via sensor translation and freeform surface rotation. Based on normal tracking principle, a position-sensitive detector is used to track the normal direction, solving the problem of large inclination freeform surface measurements limited by the maximum measurable inclination of the sensor. The laser differential confocal sensor is used to precisely focus of the surface, realizing a high-spatial-resolution measurement of the surface normal vector, with an axial resolution of up to 1 nm. By introducing a reference frame into the system, an independent translational motion reference is provided for freeform surface measurement. By monitoring, decoupling and compensating the 2D translational motion errors, the impact of these errors on measurement accuracy is greatly reduced. High-accuracy freeform surface shape measurement is finally realized. The experimental results show that after error compensation, the PV repeatability is superior to ±50 nm (3σ), RMS repeatability is superior to ±14 nm (3σ), and the measurement results are close to the standard values, enabling high-accuracy measurement of freeform surface shapes.
During wireless charging, the change of battery resistance will cause the fluctuation of output power, which will shorten the battery life and affect the charging safety. According to the theoretical analysis of WPT, when the load resistance changes, the output power can be stabilized by adjusting the input voltage of the system. Aiming at the variable load MCRWPT system, that is, only the load resistance changes under the resonant state, this paper designs the MCRWPT constant power control system by using the principle of reflective impedance and using the phase-shifting control voltage regulation and builds a simulation model through Matlab/Simulink platform to verify that the output power is kept in a certain range, without additional communication loops, which reduces the volume of electrical equipment and saves costs.