Pottabattula Mahesh

Mr. Pottabattula Mahesh

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2023 in Molecules
Verified
Journal Article
Open access
PDF file
PMPottabattula Mahesh
Pottabattula Mahesh
MHM AKIFUL HAQUE
M AKIFUL HAQUE
BSBaher I. Salman
Baher I. Salman
TBTarek Saied Belal
Tarek Saied Belal
AIAdel Ibrahim
Adel Ibrahim
Sami El DeebSami El Deeb
Sami El Deeb
Plaque psoriasis is a common, long-lasting illness that affects the immune system and causes significant negative impacts on a patient’s physical health, well-being, and ability to work effectively. Deucravacitinib (DEU) is the first oral medication used in the treatment of plaque psoriasis, a chronic skin condition that causes red, scaly patches on the skin. DEU is a type of medication called an oral Janus kinase (JAK) inhibitor, which works by blocking specific enzymes that play a role in the inflammation and immune response associated with psoriasis. Therefore, a quick, easy, novel, reliable, sensitive, and straightforward liquid chromatography-tandem mass spectrometry (LC-MS/MS) approach was used to analyze DEU in plasma samples. The LC-MS/MS method for the determination of DEU in human plasma was based on using trimethoprim as an internal standard (IS). The separation of DEU and IS was carried out via liquid–liquid extraction (LLE). The extract was then subjected to the chromatographic system separation using the ACE-C18 column (4.6 × 100 mm, 5 µm). The mobile phase employed consisted of methanol and a solution of 2 mM ammonium formate (80:20 v/v, respectively). The flow rate used was set at 0.9 mL min−1. The creative strategy was performed by running an ABSCIEX API 4000 mass spectrometer with an electron spray ionization source in multiple reaction monitoring (MRM) mode. The ion transitions m/z 426.3 → 358.2 were used for DEU quantitation, while the ion transitions m/z 291.1 → 261.1 were used for trimethoprim quantitation. The accuracy, precision, linearity, recovery, and selectivity of DEU were deemed acceptable when validated for a concentration range between 0.500 and 601.050 ng/mL, utilizing a weighting factor of 1/x2.

18 April 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
PMPottabattula Mahesh
Pottabattula Mahesh
MHM AKIFUL HAQUE
M AKIFUL HAQUE
BSBaher I. Salman
Baher I. Salman
TBTarek Saied Belal
Tarek Saied Belal
AIAdel Ibrahim
Adel Ibrahim
Sami El DeebSami El Deeb
Sami El Deeb
Plaque psoriasis is a common, long-lasting illness that affects the immune system and causes significant negative impacts on a patient's physical health, well-being, and ability to work effectively. Deucravacitinib (DEU) is the first oral medication used in the treatment of plaque psoriasis, a chronic skin condition that causes red, scaly patches on the skin. DEU is a type of medication called an oral Janus kinase (JAK) inhibitor, which works by blocking specific enzymes that play a role in the inflammation and immune response associated with psoriasis. Therefore, a quick, easy, novel, reliable, sensitive, and straightforward Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) approach was used to analyse DEU in plasma samples. The LC-MS/MS method for the determination of DEU in human plasma was based on using trimethoprim as an internal standard (IS). The separation of DEU and IS was carried out via liquid-liquid extraction (LLE). The isolated substances were then subjected to the chromatographic system using the ACE-C18 column (4.6x100 mm, 5 µm). The mobile phase employed consisted of methanol and a solution of 2 mM ammonium formate (80:20 v/v, respectively). The flow rate used was set at 0.9 mL min-1. The creative strategy was performed by running an ABSCIEX API 4000 mass spectrometer with an electron spray ionization source in Multiple Reaction Monitoring (MRM) modes. The ion transitions m/z 426.3  358.2 was used for DEU quantitation, while the ion transitions m/z 291.1  261.1 was used for trimethoprim quantitation. The accuracy, precision, linearity, recovery, and selectivity of DEU were deemed acceptable when validated for a concentration range between 0.500 to 601.050 ng/mL, utilizing a weighting factor of 1/x2.