Simone Barbera

Dr. Simone Barbera

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
GBGiuseppe Mauro Bucolo
Giuseppe Mauro Bucolo
VAVelio Ascenti
Velio Ascenti
SBSimone Barbera
Simone Barbera
FFFederico Fontana
Federico Fontana
FAFrancesco Marcello Arico
Francesco Marcello Arico
GAGiorgio Ascenti
Giorgio Ascenti
Dual-layer Dual-Energy CT (dl-DECT) allows one to create virtual non-contrast (VNC) reconstructions from contrast-enhanced CT scans, with a consequent decrease of the radiation dose. This study aims to assess the reliability of VNC for the diagnostic evaluation of renal masses in comparison with true non-contrast (TNC) images. The study cohort included 100 renal masses in 40 patients who underwent dl-DECT between June and December 2021. Attenuation values and standard deviations were assessed through the drawing of regions of interest on TNC and VNC images reconstructed from corticomedullary and nephrographic phases. A Wilcoxon signed-rank test was performed in order to assess equivalence of data and Spearman’s Rho correlation coefficient to evaluate correlations between each parameter. The diagnostic accuracy of VNC was estimated through the performance of receiver operating characteristic (ROC) curve analysis. Differences between attenuation values were, respectively, 74%, 18%, 5% and 3% (TNC-VNCcort), and 74%, 15%, 9% and 2% (TNC-VNCneph). The Wilcoxon signed-rank test demonstrated the equivalence of attenuation values between the TNC and VNC images. The diagnostic performance of VNC images in the depiction of kidney simple cysts remains high compared to TNC (VNCcort-AUC: 0.896; VNCneph-AUC: 0.901, TNC-AUC: 0.903). In conclusion, quantitative analysis of attenuation values showed a strong agreement between VNC and TNC images in the evaluation of renal masses.

Verified
Journal Article
Open access
PDF file
FPFilippo Piacentino
Filippo Piacentino
FFFederico Fontana
Federico Fontana
CBCecilia Beltramini
Cecilia Beltramini
ACAndrea Coppola
Andrea Coppola
DMDaniele Mesiano
Daniele Mesiano
MVMassimo Venturini
Massimo Venturini
Background/Objectives: Although MRI with fat-suppression sequences is the gold standard for diagnosis of bone marrow edema (BME), Dual-Layer Spectral CT (DL-SCT) with electron density (ED) provides a viable alternative, particularly in situations where an MRI is not accessible. Using MRI as the reference standard, this study analyzed how DL-SCT with ED reconstructions may be a valid alternative in the detection of BME. Methods: This retrospective study included 28 patients with a suspected diagnosis of BME via MRI conducted between March and September 2024. Patients underwent DL-SCT using ED reconstructions obtained through IntelliSpace software v. 12.1. Images were evaluated by two experienced radiologists and one young radiologist in a blinded way, giving a grade from 0 to 3 to classify BME (0 absence; 1 mild; 2 moderate; 3 severe). To reduce the recall bias effect, the order of image evaluations was set differently for each reader. p-Values were considered significant when <0.05. Fleiss’ Kappa was used to assess inter-rater reliability: agreement was considered poor for k < 0; slight for k 0.01–0.20; fair for 0.21–0.40; moderate for 0.41–0.60; substantial for 0.61–0.80; and almost perfect for 0.81–1.00. Results: All the readers detected the presence or absence of BME using DL-SCT. Inter-rater reliability for grade 0 resulted in 1 (p-value < 0.001); for grade 1: 0.21 (p-value < 0.001); for grade 2: 0.197 (p-value < 0.001); and for grade 3: 0.515 (p-value < 0.001). Conclusions: ED reconstructions allowed the identification of BME presence or absence in all analyzed cases, thus suggesting DL-SCT as a potentially effective method for its detection.

12 May 2026 in Tomography
Verified
Journal Article
Open access
PDF file
TCTommasa Catania
Tommasa Catania
GMGrazia Morabito
Grazia Morabito
SBSimone Barbera
Simone Barbera
MVMassimo Venturini
Massimo Venturini
FFFederico Fontana
Federico Fontana
GAGiorgio Ascenti
Giorgio Ascenti
Background: Differentiating adrenal adenomas from non-adenomatous lesions remains a critical challenge in the management of adrenal incidentalomas. Conventional unenhanced CT relies on attenuation thresholds of 10 HU and 20 HU, which present trade-offs between sensitivity and specificity. Objectives: To evaluate the diagnostic performance of unenhanced Spectral CT using the attenuation difference between 40 keV and 140 keV virtual monoenergetic images for differentiating adrenal adenomas from non-adenomatous lesions. Methods: In this retrospective single-center study, 60 patients with adrenal lesions who underwent unenhanced dual-energy CT were included. Mean attenuation values were measured on conventional images and on virtual monoenergetic images at 40 keV and 140 keV. The spectral attenuation difference (Δ40–140 keV) was calculated. ROC analysis was performed to determine the optimal threshold and diagnostic performance. Additional analyses included DeLong comparison of correlated ROC curves and bootstrap resampling to estimate 95% confidence intervals for the area under the curve. Results: Forty-nine lesions were adenomas and eleven were non-adenomatous. The optimal threshold for Δ40–140 keV was −17 HU. When evaluated as a continuous variable, Δ40–140 keV yielded an area under the curve of 0.940 (95% confidence interval: 0.851–1.000), compared with 0.939 (95% confidence interval: 0.870–0.992) for conventional unenhanced attenuation. DeLong comparison showed no statistically significant difference between the two curves (p = 0.980). Diagnostic performance was as follows: HU ≤ 10 (AUC 0.816, diagnostic accuracy 0.70), HU ≤ 20 (AUC 0.883, diagnostic accuracy 0.87), and Δ40–140 keV ≤ −17 HU (AUC 0.940, diagnostic accuracy 0.90). The spectral attenuation difference demonstrated the highest overall diagnostic accuracy. Conclusions: Unenhanced Spectral CT using Δ40–140 keV improves discrimination between adrenal adenomas and non-adenomatous lesions compared with conventional attenuation thresholds. This technique may reduce indeterminate findings and limit the need for additional imaging.

17 January 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
FFFederico Fontana
Federico Fontana
FPFilippo Piacentino
Filippo Piacentino
AGAroa Gnesutta
Aroa Gnesutta
EMEdoardo Macchi
Edoardo Macchi
ACAndrea Coppola
Andrea Coppola
MVMassimo Venturini
Massimo Venturini
Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical implantation and its implementation is progressively increasing worldwide. We routinely perform pre-procedural aortic angiography CT to assess aortic dimensions and vascular anatomy. This study aims to evaluate the image quality of CTA for TAVI planning using dual-layer spectral CT, with virtual monoenergetic image reconstructions at 40 keV. Thirty-one patients underwent a CTA protocol with the injection of 20 mL of contrast media. Image quality was assessed by measuring the mean density in Hounsfield Units (HU), the signal-to-noise ratio, and the contrast-to-noise ratio in VMI reconstructions. Additionally, a blinded subjective analysis was conducted by two observers. The results showed significant enhancement at all sampled vascular levels with a gradual decrease in HU from proximal to distal regions. Favourable subjective ratings were given for all parameters, with greater variability in the evaluation of iliac axes. A significant negative correlation (p < 0.05) was observed between BMI and CA at all vascular levels, indicating reduced contrast enhancement with increasing BMI. Spectral CT, along with reducing iodine load, allows for obtaining high-quality images without a significant increase in noise. The reduction in iodine load can have positive implications in clinical practice, improving patient safety and resource efficiency.

8 April 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
TCTommasa Catania
Tommasa Catania
GMGrazia Morabito
Grazia Morabito
SBSimone Barbera
Simone Barbera
MVMassimo Venturini
Massimo Venturini
FFFederico Fontana
Federico Fontana
GAGiorgio Ascenti
Giorgio Ascenti
Background: Differentiating adrenal adenomas from non-adenomatous lesions remains a critical challenge in the management of adrenal incidentalomas. Conventional unenhanced CT relies on attenuation thresholds of 10 HU and 20 HU, which present trade-offs between sensitivity and specificity. Objectives: To evaluate the diagnostic performance of unenhanced Spectral CT using the attenuation difference between 40 keV and 140 keV virtual monoenergetic images for differentiating adrenal adenomas from non-adenomatous lesions. Methods: In this retrospective single-center study, 60 patients with adrenal lesions who underwent unenhanced dual-energy CT were included. Mean attenuation values were measured on conventional images and on virtual monoenergetic images at 40 keV and 140 keV. The spectral attenuation difference (Δ40–140 keV) was calculated. ROC analysis was performed to determine optimal thresholds and diagnostic performance. Results: Forty-nine lesions were adenomas and eleven were non-adenomatous. The optimal threshold for Δ40–140 keV was −17 HU. Diagnostic performance was as follows: HU ≤10 (AUC 0.816, diagnostic accuracy 0.70), HU ≤20 (AUC 0.883, diagnostic accuracy 0.87), and Δ40–140 keV ≤ −17 HU (AUC 0.940, diagnostic accuracy 0.90). The spectral attenuation difference demonstrated the highest overall diagnostic accuracy. Conclusions: Unenhanced Spectral CT using Δ40–140 keV improves discrimination between adrenal adenomas and non-adenomatous lesions compared with conventional attenuation thresholds. This technique may reduce indeterminate findings and limit the need for additional imaging.

12 September 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
SMSilvio Mazziotti
Silvio Mazziotti
GAGiorgio Ascenti
Giorgio Ascenti
TDTommaso D'Angelo
Tommaso D'Angelo
LLLudovica Rosa Maria Lanzafame
Ludovica Rosa Maria Lanzafame
PAPasquale Arena
Pasquale Arena
GCGiuseppe Cicero
Giuseppe Cicero
Background/Objectives: To evaluate the concordance of dual-layer spectral CT (DLSCT) with MRI in locoregional staging of rectal cancer, focusing on 40 keV virtual monoenergetic reconstructions. Methods: This retrospective single-center study included 31 patients (mean age, 69 ± 13.3 years) with rectal cancer who underwent both MRI and DLSCT within 30 days before treatment. Venous-phase CT images were reconstructed at 40 keV. Assessed parameters included tumor location, longitudinal extent, distance from the anorectal junction and anal verge, mesorectal infiltration, circumferential resection margin (CRM) involvement, suspicious lymph nodes, extramural vascular invasion (EMVI), desmoplastic reaction, peritoneal involvement, and anal canal invasion. Two radiologists performed consensus readings. Paired continuous measurements were compared with the Wilcoxon signed-rank test. Agreement for categorical variables was evaluated using Cohen’s kappa; sensitivity, specificity, and accuracy were calculated using MRI as the imaging reference standard. Results: No significant differences were found between MRI and DLSCT for the continuous measurements evaluated. Complete agreement was observed for CRM involvement, anal canal invasion, peritoneal involvement, desmoplastic reaction, and suspicious lymph-node classification (accuracy, 100%; κ = 1.00). Agreement was almost perfect for mesorectal infiltration (κ = 0.84). For EMVI, DLSCT reproduced all MRI-positive classifications but generated two additional positive findings, resulting in 100% sensitivity, 71.4% specificity, 93.5% accuracy, and substantial agreement (κ = 0.79). Conclusions: DLSCT showed high concordance with MRI for several locoregional imaging features of rectal cancer. It may provide complementary information, particularly when MRI is contraindicated or inconclusive. In addition, when DLSCT is performed for systemic staging, it has the potential to provide both locoregional and distant disease assessment within a single examination. However, these findings do not establish equivalence to MRI or diagnostic accuracy against histopathology, and further prospective studies with pathological correlation are warranted.