Aim: The regulation of blood glucose levels is controlled by insulin, which is produced by the pancreatic beta system. Inadequate synthesis of beta insulin, results in elevated glucose levels, a condition known as diabetes, which can lead to various chronic health issues. In recent times, the diagnosis of diabetes, particularly type 1, has shifted towards the direct measurement of insulin levels. To facilitate this, an immunosensor was created to enable rapid and sensitive examination of insulin levels, with the goal of improving the quality for life for diabetic patients. Material and Method: For this purpose, an insulin tracer protein based biosensor was designed for the determination of insulin at all solutions. For determination of insulin, electrobiochemical analyses were performed. Optimisation and characterisation studies were performed using differential pulse voltammetry. The performance of bioelectrochemical system was analysed by Receiver Operating Characteristic method. Results: The insulin biosensor cyclic woltammogram was obtained between -0,1 and 0,6 V potantial. At 0,45 V was found as the anodic peak side for determination the insulin. Optimisation and characterisation studies performed at 0,45 V with differential pulse voltammetry. Conclusion: The study successfully identified stable and easy-to-use insulin concentrations, indicating the potential of the newly developed immunosensor for applications in clinical biochemistry laboratories.
1 January 2023 in İstanbul Gelişim Üniversitesi Sağlık Bilimleri Dergisi
Aim: The detection of cholesterol concentration in the blood is an important parameter in the diagnosis and follow-up of many diseases, including cardiovascular and hepatobiliary diseases. Nowadays, various methods have been used for the routine analysis of cholesterol, including spectrophotometric, high-performance liquid chromatography (HPLC), and amperometric methods. Since biosensors have advantages such as high sensitivity, fast response, low cost, small size, continuous online detection, and reproducible results, it is aimed to develop a biosensor method for cholesterol determination. Methods: Polymer film immobilization was performed on the gold electrode surface electrochemically in an acetonitrile-water medium containing o-phenylenediamine and benzoquinone. Cholesterol oxidase (ChOx, E.C. 1.1.3.6) enzyme was immobilized on the polymer film-immobilized electrode surface by the self-forming monolayer method. Optimization and characterization studies were carried out for the determination of cholesterol with the prepared electrodes. Results: The determination of cholesterol was performed via monitoring the oxidation current of enzymatically produced H2O2 at 0.70 V Ag/AgCl. Optimum biosensor conditions were determined for phosphate buffer at 0.1M, pH 7.0, and 30°C for the Au/oPD-BQ/ChOx enzyme electrode. The linear working range is 9.8×10-6-1.1×10-2 mM, and the cholesterol detection limit is 9.8×10-6 mM. The analysis of total cholesterol in solutions was performed using the proposed Au/oPD-BQ/ChOx electrode. Conclusion: A convenient, simple, reproducible, and stable method was developed for the determination of cholesterol by immobilizing cholesterol oxidase on the prepared electrode surface through a polymer film. The sensor we designed can be expanded to improve the detection of many analytes in the clinic.
Apoptozis üzerinde uzun süredir çalışılan bir hücre ölüm tipidir. Son 30 yıl boyunca bu hücre ölüm tipi oldukça geniş bir şekilde araştırılmış ve bu hücre intiharının altında yatan moleküler mekanizmalar açıklanmıştır. Apoptozisin çok az ya da çok fazla olması hematolojik bozukluklar, otoimmün hastalıklar, nörodejeneratif hastalıklar, iskemik hasar ve birçok kanser türü gibi durumları içeren önemli bir etmendir. Bu amaçla apoptoz araştırma alanı muazzam bir hızla ilerlemektedir. Anahtar apoptotik ve antiapoptotik proteinlerin birçoğu tanımlanmasına rağmen bu proteinlerin etkisinin ve etkili olmamasının moleküler mekanizmalarının araştırılmasına ihtiyaç vardır. Bu derlemenin amacı apoptotik mekanizmaları, hastalıkta ve sağlıkta apoptozisin rolü, kanser tedavisinde apoptozisten yararlanılarak oluşturulan terapötik fırsatlar ve tedavi örneklerini içeren apoptozis sürecinde güncel bilgilere genel bir bakış sağlamaktır.
1 December 2022 in European Journal of Therapeutics
Objective: Age brings about changes to the oxidant and antioxidant balance of male testis that give rise to loss of fertility. The Ferula elaeochytris root extract (FE), contents antioxidant and anti-inflammatory component, have been used to treat infertility by local people for centuries. The main objectives of this study were to determine whether FE was effective on sperm quality, spermatogenesis, apoptosis and oxidative stress in aged rat. Methods: Four groups were formed with 40 rats; young Control (YC), Aged Control (AC), Ferula elaeochytris administrated aged rat (A+FE) and vitamin E administrated aged rat (A+VE). Vitamin E and FE was administered orally for 8 weeks. Results: The administration of FE significantly increased serum TAS, testetorone levels and decreased testicular malondialdehyde (MDA) activity, that these changes were accompanied by the reduced serum TNF-α, and TOS levels. Also, the apoptosis germ cell, the tubular diameter, the germinal epithelium height and Johnson’s score a have been regulated after administration of FE (p<0.05). Meanwhile, in the present context, in aged group the sperm count, motility, testicular weight declined significantly. FE showed showed significantly increased effect on the motility and sperm count. Conclusive: These findings support that aging induces stress oxidative and inflammation, and FE could protect the testis against these damaging effects via its anti-oxidative, anti-inflammatory action and modulate spermatogenesis.
12 December 2019 in Journal of the Mexican Chemical Society
Ultrasound is used in many analysis studies, including liquid mixtures. Many mixtures are analyzed to understand their contents or properties in different situations. One of these mixtures is the ethanol-water combination. In this study, the amount of ethanol in the liquid mixture was determined noninvasively by the ultrasonic method using a microcontroller-based system. The results show that the measurements obtained were within the p<0.05 confidence interval. The characteristics evaluation of the system shows that the system can detect ethanol concentration as low as 0.552 g/L, thus the system has a broad and linear determination range for ethanol. Although the system is calibrated and tested with ethanol-water mixture, it can be used for any mixture that changes density related to the substance concentration, including different alcohols which are soluble in water (glycols, glycoethers, etc.) or any other material (solid or liquid) which is soluble in alcohol or different liquid solvent. The system has so many advantages that make it possible to use comfortably in many areas where the amount of ethanol contained in the mixture is essential. These advantages are the high accuracy and sensitivity, being noninvasive, portable, and not having a destructive effect on the substance. Resumen. El ultrasonido es utilizado en muchos estudios incluyendo las mezclas liquidas. Se analizan varias mezclas para entender sus contenidos y propiedades en diferentes situaciones. Una de estas mezclas es la combinación de etanol-agua. En este estudio, la cantidad de etanol en la mezcla líquida fue determinada de manera no invasiva con el método ultrasonico utilizando un sistema basado en microcontrolador. Los resultados muestran que las mediciones obtenidas se encontraban dentro de un intervalo de confianza de p<0.05. Las características de evaluación del sistema muestran que se puede detectar etanol a una concentración tan baja como 0.552 g/L, por lo tanto, el sistema tiene un rango de determinación linear amplio para etanol. Aunque el sistema se calibra y prueba con mezcla de etanol-agua, puede ser utilizado para cualquier mezcla que cambia de densidad en relación con la concentración de la substancia, incluyendo diferentes alcoholes que son solubles en agua (glicoles, glicoeteres, etc) o cualquier otro material (sólido o líquido) que sea soluble en alcohol o en algún solvente líquido diferente. El sistema tiene muchas ventajas que hacen posible su utilización en muchas áreas donde la cantidad de etanol contenida en la mezcla es esencial. Estas ventajas son de alta precisión y sensiblididad al ser no invasivo, portátil y al no tener un efecto destructivo sobre la sustancia.