Ahmet Aydın

Dr. Ahmet Aydın

Biomedical Engineering, Cukurova University, Adana, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2012 in Automation in Construction
Verified
Journal Article
Closed access
MOMustafa Oral
Mustafa Oral
EOEmel Laptali Oral
Emel Laptali Oral
AAAhmet Aydın
Ahmet Aydın

15 December 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BASHAR S. FalihBASHAR S. Falih
BASHAR S. Falih
MSMohannad Kadhim Sabir
Mohannad Kadhim Sabir
AAAhmet Aydın
Ahmet Aydın
Early screening is a key component of intensive intervention therapy and rehabilitation for children with autism spectrum disorder (ASD). Electroencephalogram (EEG) signals provide real-time, high-sensitivity monitoring of pathological activities in children with ASD. This study used a dataset of 52 samples with 19-channel sleep data and proposed a new approach to diagnosing ASD based on energy differences between the left and right hemispheres of the brain. The preprocessing stage included decimation, band-pass filtering to remove unwanted frequencies, artifact subspace reconstruction to eliminate artifacts, and amplitude normalization to preserve the relative relationships between the signal features, which were crucial for the subsequent analysis and classification. Five band-pass filters were applied to decomposing the EEG signals. For each decomposed band, the signals from each brain hemisphere were analyzed separately by calculating the peak sensor’s envelope and obtaining the mean envelope for each hemisphere, resulting in two mean signals (right and left). Features were extracted using a sliding window approach applied to the mean signals of each hemisphere, with varying overlap ratios (12.5% to 87.5%, in 12.5% steps). The maximum, mean, and minimum energy values were used individually as features. Three types of SVM kernels—linear (L), the radial basis function (RBF), and quadratic—were employed for classification. The proposed method achieved the highest accuracy, sensitivity, and F1-score of 91.7%, 91.4%, and 91.6%, respectively, in the Theta band using SVM-L with the maximum energy features and the maximum overlap ratio.

13 November 2020 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
PDF file
CKCemil Keskinoğlu
Cemil Keskinoğlu
AAAhmet Aydın
Ahmet Aydın
Joint movements are the key factor for the mobility of the people during daily activities. The evaluation of the joint movements is determined by the range of motion (ROM) parameters. The ROM might change due to age, gender, and some diseases. Therefore, it is essential to measure ROM accurately and compare it with the normal values of the healthy people. In this study, a low-cost, wireless, and wearable electrogoniometer was designed for highly precise and accurate measurements. The stability of the measurements is guaranteed with the quaternion based Kalman filter. The measurements of the developed system are compared with the traditional goniometer. The concordance correlation coefficient is calculated as a similarity metric, and the result is obtained as 1 . In addition, a GUI was prepared to present 3D visualization of the movements in real-time with the ROM measurements and give visual feedback to the physiotherapists during physical examinations and to the patient during the home therapy sessions. The measurements also can be recorded using the GUI for retrospective analysis.

5 January 2021 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
AŞAsiye Şahin
Asiye Şahin
AAAhmet Aydın
Ahmet Aydın

1 July 2012 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
AAAhmet Aydın
Ahmet Aydın
TIT. İbRikçi
T. İbRikçi
IAİ. D. Akçali
İ. D. Akçali
In the field of orthopaedics, treatment of extremity deformities can be realised by means of external fixators. However, control of such biomedical system is very difficult. Some different mathematical models have been developed to improve quality of this service. Most of the parameters, which are used in these models, have been obtained from two orthogonal X-ray images: one from anteroposterior, AP, direction and the other from a lateral, L, direction. The quality of the results of this model is dependent on the accuracy of the input parameters. Measuring these parameters is a time-consuming issue, and the accuracy of the results is also low. To increase the quality of the measurement, the reference points should be chosen from the edges of the biomedical system, and it is important to find the edges without noise. To achieve this purpose, Sobel edge detector, binary large object analysis, thresholding and inverting are applied as image processing steps. The results are compared with manual measurement values which have been obtained earlier. The results show that semi-automatic measurement of the parameters is more accurate and faster than manual measurement. It shows that the efficiency of the fixator method has been improved.

1 June 2014
Verified
Conference Paper
Closed access
IAİ. D. Akçalı
İ. D. Akçalı
EAErcan Avsar
Ercan Avsar
MUM. K. Un
M. K. Un
AAAhmet Aydın
Ahmet Aydın
TIT. İbrikçi
T. İbrikçi
ADA. Durmaz
A. Durmaz
External fixators are widely used in the area of orthopedics to manage deformities and fractures. The historical trend in obtaining a mechanical infrastructure has shifted from simple devices like pins, rods, and hinges to more sophisticated frames involving parallel manipulators. Despite advantages of such robotic frames especially in removing stiffness issues, there are still problems associated with the reliable deployment of these modern devices. Problems like singularity, possibilities of guiding fragments along many different trajectories have been handled in this paper. A method has been shown how to detect singularity in displaced, aligned, and intermediate positions of the fragments. How the robotic system could be actuated according to different functions have been investigated, in addition to their effects on trajectories of distal fragment end. These considerations have been demonstrated on numerical examples.