Chaicharoen Tantanate

Chaicharoen Tantanate

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2017 in Archives of Pathology & Laboratory Medicine
Verified
Journal Article
Closed access
CTChaicharoen Tantanate
Chaicharoen Tantanate
LKLadawan Khowawisetsut
Ladawan Khowawisetsut
KPKovit Pattanapanyasat
Kovit Pattanapanyasat
Context.—: Spurious platelet counts from automated methods have been reported in patients with abnormal red blood cells. However, there is no specific study regarding performance of platelet counts by automated methods in patients with thalassemia. Objective.—: To investigate the performance of automated platelet counts, including impedance (PLT-I) and optical fluorescent (PLT-O and PLT-F) methods, and compare them with the international reference method (IRM) for platelet counting in patients with thalassemia. Design.—: Two hundred forty-nine thalassemia specimens from various subtypes were examined. PLT-I, PLT-O, and PLT-F from a Sysmex XN analyzer were evaluated and compared against the IRM. Demographic data, platelet counts, and red blood cell parameters are shown. Comparability between evaluated methods and IRM, as well as test characteristics, is presented. Factors involving inaccurate PLT-I were analyzed. Results.—: Specimens with platelet counts ranging from 31 × 103/μL to 932 × 103/μL were included. Most patients were patients with thalassemia major. Correlation between PLT-I and IRM was lower than that of the other methods in overall patients. PLT-O and PLT-F were correlated to IRM when classifying patients according to clinically significant platelet ranges. All automated methods had acceptable sensitivities; however, specificity of PLT-I was low for diagnosis of thrombocytopenia. High RDW-CV (red blood cell distribution width–coefficient of variation) was an independent factor of inaccurate PLT-I measurement. Conclusions.—: Among the evaluated methods, PLT-I was the method least correlated to IRM, with PLT-O and PLT-F comparable to IRM in patients with thalassemia. Optical platelet counts and careful blood smear examination are recommended alternative platelet counting methods, depending on the clinical setting.

24 October 2017 in Journal of Thrombosis and Haemostasis
Verified
Journal Article
Closed access
PDF file
ABA. M. H. P. van Den Besselaar
A. M. H. P. van Den Besselaar
VCV. Chantarangkul
V. Chantarangkul
FAF. Angeloni
F. Angeloni
NBN. B. Binder
N. B. Binder
MBM. Byrne
M. Byrne
ATArmando Tripodi
Armando Tripodi

11 September 2014 in International Journal of Laboratory Hematology
Verified
Journal Article
Closed access
PDF file
CTChaicharoen Tantanate
Chaicharoen Tantanate
CKC. Klinbua
C. Klinbua

15 June 2018 in Laboratory Medicine
Verified
Journal Article
Closed access
CTChaicharoen Tantanate
Chaicharoen Tantanate
CKCherdsak Klinbua
Cherdsak Klinbua
To investigate the association between high-fluorescence lymphocyte cell (HFLC) and atypical lymphocyte (AL) counts, and to determine the clinical significance of HFLC. We compared automated HFLC and microscopic AL counts and analyzed the findings. Patient clinical data for each specimen were reviewed. A total of 320 blood specimens were included. The correlation between HFLC and microscopic AL counts was 0.865 and 0.893 for absolute and percentage counts, respectively. Sensitivity, specificity, and accuracy of HFLC at the cutoff value of 0.1 × 109 per L for detection of AL were 0.8, 0.77, and 0.8, respectively. Studied patients were classified into 4 groups: infection, immunological disorders, malignant neoplasms, and others. Patients with infections had the highest HFLC. Most of those patients (67.7%) had dengue infection. HFLC counts were well-correlated with AL counts with the acceptable test characteristics. Applying HFLC flagging may alert laboratory staff to be aware of ALs.

22 July 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
WWWan Hui Wong
Wan Hui Wong
CTChuen Wen Tan
Chuen Wen Tan
NKNabeelah Binti Abdul Khalid
Nabeelah Binti Abdul Khalid
NDNadjwa Zamalek Dalimoenthe
Nadjwa Zamalek Dalimoenthe
CYChristina Yip
Christina Yip
HNHeng Joo Ng
Heng Joo Ng
(1) Background: The activated partial thromboplastin time (APTT)- based clot waveform analysis (CWA) quantitatively extends information obtained from the APTT waveform through its derivatives. However, pre-analytical variables including reagent effects on the CWA parameters are poorly understood and must be standardized as a potential diagnostic assay. (2) Methods: CWA was first analysed with patient samples to understand reagent lot variation in three common APTT reagents: Pathromtin SL, Actin FS, and Actin FSL. A total of 1055 healthy volunteers were also recruited from seven institutions across the Asia-Pacific region and CWA data were collected with the Sysmex CS analysers. (3) Results: CWA parameters varied less than 10% between lots and the linear mixed model analysis showed few site-specific effects within the same reagent group. However, the CWA parameters were significantly different amongst all reagent groups and thus reagent-specific 95% reference intervals could be calculated using the nonparametric method. Post-hoc analysis showed some degree of influence by age and gender with weak correlation to the CWA (r < 0.3). (4) Conclusions: Reagent type significantly affects APTT-based CWA with minimal inter-laboratory variations with the same coagulometer series that allow for data pooling across laboratories with more evidence required for age- and gender-partitioning.

14 February 2019 in Scandinavian Journal of Clinical and Laboratory Investigation
Verified
Journal Article
Closed access
CTChaicharoen Tantanate
Chaicharoen Tantanate
LKLadawan Khowawisetsut
Ladawan Khowawisetsut
KSKasama Sukapirom
Kasama Sukapirom
KPKovit Pattanapanyasat
Kovit Pattanapanyasat
The aim of this study was to evaluate the performance of automated impedance platelet counts by Beckman Coulter LH780 (PLT-LH), Sysmex XN-3000 (PLT-XNi) and fluorescence method by Sysmex XN-3000 (PLT-F) in patients with acute leukemia. Blood specimens were subjected to platelet measurements by evaluated methods and then compared against the international reference method (IRM). Eighty-two blood specimens were included. Bland–Altman plots of the differences between the evaluated methods and IRM demonstrated mean biases of PLT-LH, PLT-XNi and PLT-F of 9 × 109/L, 11 × 109/L and 2 × 109/L, respectively. For platelet transfusion guidance, all evaluated methods had acceptable accuracy. For platelet transfusion guidance, the sensitivities of PLT-LH, PLT-XNi and PLT-F were 33.3, 25.0 and 83.3%, respectively, at a transfusion threshold of 10 × 109/L, and 73.1, 61.5 and 84.6%, respectively, at transfusion threshold of 20 × 109/L. High blast count was associated with inaccurate PLT-LH and PLT-XNi. In conclusion, the PLT-F demonstrated excellent performance for diagnosis of thrombocytopenia and for platelet transfusion guidance in the evaluated specimens from acute leukemia patients. With respect to clinical relevance, careful blood smear review is necessary in case of high blast counts.