Digital twin technology offers significant benefits for addressing fracture non-unions in orthopedic trauma surgery, particularly in cases requiring revision surgery. In this study, we developed a clinically applicable digital twin workflow that integrates patient-specific imaging, motion capture, musculoskeletal modeling, and finite element simulation. We applied this workflow to five real patient cases involving different anatomical sites and treatment strategies, including implant modification, augmentative fixation, and corrective osteotomy. Each case was virtually reconstructed to evaluate mechanical conditions before and after revision surgery. The results demonstrated that digital twins can predict improvements in implant stress distribution and fracture strain states, offering valuable insights for optimizing surgical decisions. This work highlights the feasibility of digital twins and their clinical value in supporting individualized revision strategies, laying the foundation for their broader use in trauma care. .
The individual assessment of the postoperative healing situation contributes significantly to detecting healing disorders, ensuring the mechanical stability of implants, and planning revision surgeries. Our established workflow consists of the following steps: (1) Monitoring of the patients during their treatment course with a motion capturing system as kinematic and sensor insoles for the kinetic gait analysis, (2) transfer of the motion data into the musculoskeletal simulation system AnyBody™ to achieve the corresponding individual muscle and joint forces. (3) Clinical imaging of the patients via postoperative computed tomography scans, ideally combined with a six-rod bone density calibration phantom. (4) Segmentation of the CT images and generation of the corresponding adaptive finite element meshes of the bone-implant systems, including the material parameters based on Hounsfield units and calibration phantom via the software ScanIP™. (5) Based on the patient-specific model, all information from the musculoskeletal simulation and gait analysis is transferred to our biomechanical simulation process as patient-specific constraints. This workflow allows us to simulate individual patient models based on their respective actual motion data over their treatment course. Thus, pathological processes that may lead to non-healing fractures can be detected early after surgery and prevented by adapting the postoperative treatment protocol. Furthermore, it is possible to understand the forces that affect the fracture and its healing process permanently in more detail. The findings demonstrate that the individual motion parameters and fracture morphology influence the local healing parameters and create individual weight-bearing recommendations.
Background: Advanced sensor insoles and motion capture technology can significantly enhance the monitoring of rehabilitation progress for patients with distal tibial fractures. This study leverages the potential of these innovative tools to provide a more comprehensive assessment of a patient’s gait and weight-bearing capacity following surgical intervention, thereby offering the possibility of improved patient outcomes. Methods: A patient who underwent distal medial tibial plating surgery in August 2023 and subsequently required revision surgery due to implant failure, involving plate removal and the insertion of an intramedullary nail in December 2023, was meticulously monitored over a 12-week period. Initial assessments in November 2023 revealed pain upon full weight-bearing without crutches. Following the revision, precise weekly measurements were taken, starting two days after surgery, which instilled confidence in accurately tracking the patient’s progress from initial crutch-assisted walking to full recovery. The monitoring tools included insoles, hand pads for force absorption of the crutches, and a motion capture system. The patient was accompanied throughout all steps of his daily life. Objectives: The study aimed to evaluate the hypothesis that the approximation and formation of a healthy gait curve are decisive tools for monitoring healing. Specifically, it investigated whether cadence, imbalance factors, and ground reaction forces could be significant indicators of healing status and potential disorders. Results: The gait parameters, cadence, factor of imbalance ground reaction forces, and the temporal progression of kinematic parameters significantly correlate with the patient’s recovery trajectory. These metrics enable the early identification of deviations from expected healing patterns, facilitating timely interventions and underscoring the transformative potential of these technologies in patient care. Conclusions: Integrating sensor insoles and motion capture technology offers a promising approach for monitoring the recovery process in patients with distal tibial fractures. This method provides valuable insights into the patient’s healing status, potentially predicting and addressing healing disorders more effectively. Future studies are recommended to validate these findings in a larger cohort and explore the potential integration of these technologies into clinical practice.
Temporomandibular joint replacement is a critical intervention for severe temporomandibular joint disorders, enhancing pain levels, jaw function and overall quality of life. In this study, we compare two finite element method-based simulation workflows from both academic and industrial perspectives, focusing on a patient-specific case involving a custom-made temporomandibular joint prosthesis. Using computed tomography data and computer-aided design data, we generated different 3D models and performed mechanical testing, including wear and static compression tests. Our results indicate that the academic workflow, which is retrospective, purely image-based and applied post-operatively, produced peak stress values within 9–20% of those obtained from the industrial workflow. The industrial workflow is prospective, pre-operative, computer-aided design-based and guided by stringent regulatory standards and approval protocols. Observed differences between workflows were attributed primarily to distinct modelling assumptions, simplifications and constraints inherent in each method. To explicitly quantify these differences, multiple additional models were generated within the academic workflow using partial data from the industrial process, revealing specific sources of variation in stress distribution and implant performance. The findings underscore the potential of patient-specific simulations not only to refine temporomandibular joint prosthesis design and enhance patient outcomes, but also to highlight the interplay between academic research methodologies and industrial standards in the development of medical devices.
25 September 2025 in Frontiers in Bioengineering and Biotechnology
Purpose: The prescribed amount of weight-bearing after tibial plateau fractures is controversial because it affects osteosynthetic construct stability and fracture healing. We aim to introduce a simulation model that adequately predicts the effects of different weight-bearing amounts on stability and healing, based on the patient’s individual fracture pattern and treatment construct.Methods: To safely test different amounts of weight-bearing limits, we first extracted knee joint forces for different weight-bearing limits from musculoskeletal simulation based on monitoring data of 22 uninjured participants. Correct loading was ensured with a force-measuring insole. We then tested three patients after tibial plateau fracture with their current weight-bearing level and constructed a simulation model determining implant stress, knee joint force, and fracture gap interfragmentary strain. The patient-specific weight-bearing level was then substituted for weight-normalized uninjured participant data to test different weight-bearing levels in the simulation model.Results: The simulation model calculated individual construct stiffness and interfragmentary strain at different weight-bearing levels following the clinical course. When comparing the patient’s individual weight-bearing input with the weight-normalized input of the uninjured participants at the same level, comparable knee joint forces were extracted, showing the feasibility of this approach.Conclusion: Using an adapted reference movement database, the model allows the determination of safe weight-bearing ranges concerning construct stability and fracture healing based on individual fracture morphology and treatment without exposing patients to excessive weight-bearing. Future studies can test this approach in more extensive patient-number studies and different treatment situations.
Temporomandibular joint replacement is a critical intervention for severe temporomandibular joint disorders, enhancing pain levels, jaw function, and overall quality of life. In this study, we compare two finite element method-based simulation workflows from both academic and industrial perspectives, focusing on a patient-specific case involving a custom-made temporomandibular joint prosthesis. Using computed tomography data and computer-aided design data, we generated different 3D models and performed mechanical testing, including wear and static compression tests. The results demonstrate that the academic, retrospective, and purely image-based approach, applied post-operatively, yields biomechanical insights comparable to those derived from the industrial, pre-operative, planning-based process, which is additionally guided by regulatory requirements and approval protocols. Minor variations between the two workflows are primarily due to different assumptions, simplifications and constraints imposed by the regulatory framework. To elaborate the differences, various models were generated in the academic workflow, partly based on the data of the industrial process. These findings underscore the potential of patient-specific simulations not only to refine temporomandibular joint prosthesis design and enhance patient outcomes, but also to highlight the interplay between academic research methodologies and industrial standards in the development of medical devices.