Kerstin Wickert

Ms. Kerstin Wickert


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2022 in Acta Biomaterialia
Verified
Journal Article
Open access
Bergita GanseBergita Ganse
Bergita Ganse
MOMarcel Orth
Marcel Orth
MRMichael Roland
Michael Roland
SDStefan Diebels
Stefan Diebels
Paul MotzkiPaul Motzki
Paul Motzki
TPTim Pohlemann
Tim Pohlemann
Nonunion is a complication of long bone fractures that leads to disability, morbidity and high costs. Early detection is difficult and treatment through external stimulation and revision surgery is often a lengthy process. Therefore, alternative diagnostic and therapeutic options are currently being explored, including the use of external and internal sensors. Apart from monitoring fracture stiffness and displacement directly at the fracture site, it would be desirable if an implant could also vary its stiffness and apply an intervention to promote healing, if needed. This could be achieved either by a predetermined protocol, by remote control, or even by processing data and triggering the intervention itself (self-regulated 'intelligent' or 'smart' implant). So-called active or smart materials like shape memory alloys (SMA) have opened up opportunities to build active implants. For example, implants could stimulate fracture healing by active shortening and lengthening via SMA actuator wires; by emitting pulses, waves, or electromagnetic fields. However, it remains undefined which modes of application, forces, frequencies, force directions, time durations and periods, or other stimuli such implants should ideally deliver for the best result. The present paper reviews the literature on active implants and interventions for nonunion, discusses possible mechanisms of active implants and points out where further research and development are needed to build an active implant that applies the most ideal intervention. STATEMENT OF SIGNIFICANCE: Early detection of delays during fracture healing and timely intervention are difficult due to limitations of the current diagnostic strategies. New diagnostic options are under evaluation, including the use of external and internal sensors. In addition, it would be desirable if an implant could actively facilitate healing ('Intelligent' or 'smart' implant). Implants could stimulate fracture healing via active shortening and lengthening; by emitting pulses, waves, or electromagnetic fields. No such implants exist to date, but new composite materials and alloys have opened up opportunities to build such active implants, and several groups across the globe are currently working on their development. The present paper is the first review on this topic to date.

8 March 2024 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
KWKerstin Wickert
Kerstin Wickert
MRMichael Roland
Michael Roland
AAAnnchristin Andres
Annchristin Andres
SDStefan Diebels
Stefan Diebels
BGBergita Ganse
Bergita Ganse
MOMarcel Orth
Marcel Orth
Introduction: The management of fractured bones is a key domain within orthopedic trauma surgery, with the prevention of delayed healing and non-unions forming a core challenge. This study evaluates the efficacy of the AO Fracture Monitor in conjunction with biomechanical simulations to better understand the local mechanics of fracture gaps, which is crucial for comprehending mechanotransduction, a key factor in bone healing. Through a series of experiments and corresponding simulations, the study tests four hypotheses to determine the relationship between physical measurements and the predictive power of biomechanical models.Methods: Employing the AO Fracture Monitor and Digital Image Correlation techniques, the study demonstrates a significant correlation between the surface strain of implants and interfragmentary movements. This provides a foundation for utilizing one-dimensional AO Fracture Monitor measurements to predict three-dimensional fracture behavior, thereby linking mechanical loading with fracture gap dynamics. Moreover, the research establishes that finite element simulations of bone-implant systems can be effectively validated using experimental data, underpinning the accuracy of simulations in replicating physical behaviors.Results and Discussion: The findings endorse the combined use of monitoring technologies and simulations to infer the local mechanical conditions at the fracture site, offering a potential leap in personalized therapy for bone healing. Clinically, this approach can enhance treatment outcomes by refining the assessment precision in trauma trials, fostering the early detection of healing disturbances, and guiding improvements in future implant design. Ultimately, this study paves the way for more sophisticated patient monitoring and tailored interventions, promising to elevate the standard of care in orthopedic trauma surgery.

23 March 2025 in Clinical Biomechanics
Verified
Journal Article
Open access
AAAnnchristin Andres
Annchristin Andres
Michael RolandMichael Roland
Michael Roland
KWKerstin Wickert
Kerstin Wickert
Bergita GanseBergita Ganse
Bergita Ganse
TPTim Pohlemann
Tim Pohlemann
SDStefan Diebels
Stefan Diebels
The individual assessment of the postoperative healing situation contributes significantly to detecting healing disorders, ensuring the mechanical stability of implants, and planning revision surgeries. Our established workflow consists of the following steps: (1) Monitoring of the patients during their treatment course with a motion capturing system as kinematic and sensor insoles for the kinetic gait analysis, (2) transfer of the motion data into the musculoskeletal simulation system AnyBody™ to achieve the corresponding individual muscle and joint forces. (3) Clinical imaging of the patients via postoperative computed tomography scans, ideally combined with a six-rod bone density calibration phantom. (4) Segmentation of the CT images and generation of the corresponding adaptive finite element meshes of the bone-implant systems, including the material parameters based on Hounsfield units and calibration phantom via the software ScanIP™. (5) Based on the patient-specific model, all information from the musculoskeletal simulation and gait analysis is transferred to our biomechanical simulation process as patient-specific constraints. This workflow allows us to simulate individual patient models based on their respective actual motion data over their treatment course. Thus, pathological processes that may lead to non-healing fractures can be detected early after surgery and prevented by adapting the postoperative treatment protocol. Furthermore, it is possible to understand the forces that affect the fracture and its healing process permanently in more detail. The findings demonstrate that the individual motion parameters and fracture morphology influence the local healing parameters and create individual weight-bearing recommendations.

20 May 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
AAAnnchristin Andres
Annchristin Andres
KWKerstin Wickert
Kerstin Wickert
EGElena Gneiting
Elena Gneiting
FBFranziska Binmöller
Franziska Binmöller
SDStefan Diebels
Stefan Diebels
Michael RolandMichael Roland
Michael Roland
Temporomandibular joint replacement is a critical intervention for severe temporomandibular joint disorders, enhancing pain levels, jaw function and overall quality of life. In this study, we compare two finite element method-based simulation workflows from both academic and industrial perspectives, focusing on a patient-specific case involving a custom-made temporomandibular joint prosthesis. Using computed tomography data and computer-aided design data, we generated different 3D models and performed mechanical testing, including wear and static compression tests. Our results indicate that the academic workflow, which is retrospective, purely image-based and applied post-operatively, produced peak stress values within 9–20% of those obtained from the industrial workflow. The industrial workflow is prospective, pre-operative, computer-aided design-based and guided by stringent regulatory standards and approval protocols. Observed differences between workflows were attributed primarily to distinct modelling assumptions, simplifications and constraints inherent in each method. To explicitly quantify these differences, multiple additional models were generated within the academic workflow using partial data from the industrial process, revealing specific sources of variation in stress distribution and implant performance. The findings underscore the potential of patient-specific simulations not only to refine temporomandibular joint prosthesis design and enhance patient outcomes, but also to highlight the interplay between academic research methodologies and industrial standards in the development of medical devices.

30 January 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
AAAnnchristin Andres
Annchristin Andres
KWKerstin Wickert
Kerstin Wickert
EGElena Gneiting
Elena Gneiting
FBFranziska Binmöller
Franziska Binmöller
SDStefan Diebels
Stefan Diebels
Michael RolandMichael Roland
Michael Roland
Temporomandibular joint replacement is a critical intervention for severe temporomandibular joint disorders, enhancing pain levels, jaw function, and overall quality of life. In this study, we compare two finite element method-based simulation workflows from both academic and industrial perspectives, focusing on a patient-specific case involving a custom-made temporomandibular joint prosthesis. Using computed tomography data and computer-aided design data, we generated different 3D models and performed mechanical testing, including wear and static compression tests. The results demonstrate that the academic, retrospective, and purely image-based approach, applied post-operatively, yields biomechanical insights comparable to those derived from the industrial, pre-operative, planning-based process, which is additionally guided by regulatory requirements and approval protocols. Minor variations between the two workflows are primarily due to different assumptions, simplifications and constraints imposed by the regulatory framework. To elaborate the differences, various models were generated in the academic workflow, partly based on the data of the industrial process. These findings underscore the potential of patient-specific simulations not only to refine temporomandibular joint prosthesis design and enhance patient outcomes, but also to highlight the interplay between academic research methodologies and industrial standards in the development of medical devices.