Background: Recently, minimally invasive access via right anterolateral mini-thoracotomy (RAMT) has been gaining popularity in cardiac surgery. This approach is also an option for surgeons performing aortic surgery. The aim of this study is to present our surgical method, highlighting the total endoscopic minimally invasive approach via RAMT for replacement of the ascending aorta (AAR) with or without involvement of the aortic root and the aortic valve. Methods: Clinical data of 44 patients from three participating institutions with AAR with or without involvement of the aortic valve or aortic root via RAMT between April 2017 and February 2024 were retrospectively analyzed. According to surgical procedure, patients were divided into two groups, in the AAR and in the Wheat/Bentall group with concomitant valve or root replacement. Operative time, length of ventilation, perioperative outcome, length of intensive care unit (ICU) as well as postoperative hospital stay, and mid- and long-term results were retrospectively analyzed. Results: Mean age was 61.4 ± 10.7 years old with a frequency of male gender of 63.6%. Mean cardiopulmonary bypass (CBP) time and aortic cross-clamping time was 94.9 ± 32.5 min and 63.8 ± 25.9 min, respectively. CPB and aortic clamp time were significantly lower in AAR group. In the first 24 h, the mean drainage volume was 790.3 ± 423.6 mL. Re-thoracotomy due to bleeding was zero. Sternotomy was able to be avoided in all patients. Patients stayed 35.9 ± 23.5 h at ICU and were discharged 7.8 ± 3.0 days following surgery from hospital. Mean ventilation time was 5.8 ± 7.6 h. All patients survived and 30-day mortality was 0.0%. At a median follow-up time of 18.2 months, all patients were alive. The results were similar in both groups. Conclusions: The full endoscopic RAMT approach with 3D visualization is a safe, feasible and promising technique that can be transferred in the field of aortic surgery without compromising surgical quality, postoperative outcomes, or patient safety when performed by an experienced team in a high-volume center.
The development and adoption of minimally invasive techniques has revolutionized various surgical disciplines and has also been introduced into cardiac surgery, offering patients less invasive options with reduced trauma and faster recovery time compared to traditional open-heart procedures with sternotomy. This article provides a comprehensive overview of the anesthesiologic management for minimally invasive cardiac surgery (MICS), focusing on preoperative assessment, intraoperative anesthesia techniques, and postoperative care protocols. Anesthesia induction and airway management strategies are tailored to each patient’s needs, with meticulous attention to maintaining hemodynamic stability and ensuring adequate ventilation. Intraoperative monitoring, including transesophageal echocardiography (TEE), processed EEG monitoring, and near-infrared spectroscopy (NIRS), facilitates real-time assessment of cardiac and cerebral perfusion, as well as function, optimizing patient safety and improving outcomes. The peripheral cannulation techniques for cardiopulmonary bypass (CPB) initiation are described, highlighting the importance of cannula placement to minimize tissue as well as vessel trauma and optimize perfusion. This article also discusses specific MICS procedures, detailing anesthetic considerations and surgical techniques. The perioperative care of patients undergoing MICS requires a multidisciplinary approach including surgeons, perfusionists, and anesthesiologists adhering to standardized treatment protocols and pathways. By leveraging advanced monitoring techniques and tailored anesthetic protocols, clinicians can optimize patient outcomes and promote early extubation and enhanced recovery.
Introduction The frozen elephant trunk technique (FET) has become routine for aortic arch and descending aortic repair. New hybrid prosthesis models are constantly being developed to increase effectiveness and durability of aortic repair. Recently, concerns were raised regarding increased post-operative bleeding using a new-generation hybrid prosthesis (E-vita® OPEN NEO, CryoLife Inc. JOTEC GmbH, Hechingen, Germany). We report the outcomes of a multi-centre experience of using the E-vita OPEN NEO. Methods All patients undergoing aortic surgery at five European centres using the E-vita OPEN NEO from 2020 to 2022 were included (n = 22). The primary endpoint was the amount of chest drain fluid after 24 h and re-thoracotomy rate for bleeding. Results Median patient age was 62.5 ± 12.6 years, 50.0% (11/22 patients) were female and 27.3% (6/22) of procedures were re-operative cardiac surgeries. Aortic dissection was present in 54.5% (12/22). The median cardiopulmonary bypass time was 148 min and ischaemia time was 84 min. Mortality at 30 days was 4.5% (1/22) and the stroke rate was 18.2% (4/22). The rate of re-thoracotomy for bleeding was 4.5% (1/22) with a median amount of chest drain fluid within 24 h of 569 (IQR 338–910) ml. There were no device-associated adverse events. Conclusions Use of this new-generation hybrid prosthesis for FET was safe and effective. Patient follow-up was largely uneventful given the extent of the procedures performed. In particular, bleeding events were uncommon in this cohort of patients comprising many aortic dissections and re-operative procedures. No increase in oozing was observed. Graphical Abstract
(1) Background: Despite optimal surgical therapy, replacement of the ascending aorta leads to a significant reduction in the quality of life (QoL). However, an optimal result includes maintaining and improving the QoL. The aim of our study was to evaluate the long-term outcome and the QoL in patients with aneurysms in the ascending aorta; (2) Methods: Between 2014 and 2020, 121 consecutive patients who underwent replacement of the ascending aorta were included in this study. Acute aortic pathologies were excluded. A standard short form (SF)-36 questionnaire was sent to the 112 survivors. According to the surgical procedure, patients were divided into two groups (A: supracoronary replacement of the aorta, n = 35 and B: Wheat-, David- or Bentall-procedures, n = 86). The QoL was compared within these groups and to the normal population, including myocardial infarction (MI), coronary artery disease (CAD) and cancer (CAN) patients; (3) Results: 83 patients were males (68.6%) with a mean age of 62.0 ± 12.5 years. Early postoperative outcomes showed comparable results between groups A and B, with a higher re-thoracotomy rate in B (A: 0.0% vs. B: 22.1%, p = 0.002). The 30-day mortality was zero. Overall, mortality during the follow-up was 7.4%. The SF-36 showed a significant decay in both the Physical (PCS) and Mental Component Summary (MCS) in comparison to the normal population (PCS: 41.1 vs. 48.4, p < 0.001; MCS: 42.1 vs. 50.9, p < 0.001) but without significant difference between both groups. Compared to the MI and CAD patients, significantly higher PCS but lower MCS scores were detected (p < 0.05); (4) Conclusions: Replacement of the ascending aorta shows low risk regarding the operative and postoperative outcomes with satisfying long-term results in the QoL. The extent of the surgical procedure does not influence the postoperative QoL.
Background: Minimally invasive heart valve surgery via anterolateral mini-thoracotomy with full endoscopic 3D visualization (MIS) has become the standard treatment of patients with valvular heart disease and low operative risk over the past two decades. It requires extracorporeal circulation and cardioplegic arrest. The most established form of arterial cannulation for MIS is through the femoral artery and is used by most surgeons, but it is suspected to increase the risk of stroke through retrograde blood flow. An alternative route of cannulation is the axillary artery, producing antegrade blood flow during extracorporeal circulation. Methods: Femoral or axillary cannulation for extracorporeal circulation during minimally invasive heart valve surgery (FAMI) is a multicenter randomized controlled trial designed to determine whether axillary cannulation is superior to femoral cannulation for the outcome of a manifest stroke within 7 days postoperatively. The target sample size was 848 participants. Patients ≥ 18 years of age, with valvular regurgitation or stenosis scheduled for minimally invasive surgery via anterolateral mini-thoracotomy, were randomized to axillary cannulation (treatment group) or to femoral cannulation (standard care). Patients were followed up for seven days postoperatively. A CT scan was performed pre-operatively to screen patients for vascular calcifications and to assess the safety of femoral cannulation. The standard of care is femoral artery cannulation, but is performed only in patients without significant vascular calcifications or severe kinking of the iliac arteries and in patients with sufficient vessel diameter. The cannulation is performed via Seldinger’s technique, and the vessel closed percutaneously using a plug-based vascular closure device. Only patients without significant vascular calcifications are considered for femoral cannulation, as an increased risk of stroke is assumed. In patients with vascular calcifications, axillary cannulation is the standard of care to avoid these risks. Retrospective studies have hinted that, even in patients without vascular calcifications, there may be a lower stroke risk with axillary cannulation compared to femoral cannulation. We present a protocol for a multi-center randomized trial to investigate this hypothesis. Discussion: To date, evidence on the best access for peripheral artery cannulation during minimally invasive heart valve surgery has been scarce. Patients may benefit from axillary cannulation for extracorporeal circulation in terms of stroke risk and other neurological and vascular complications, though femoral cannulation is the gold standard. The aim of this study is to determine the risks of peri-operative stroke in a prospective randomized comparison of femoral vs. axillary cannulation.
Background: Minimally invasive mitral valve surgery (MIC-MVS) has been established as preferred treatment of mitral regurgitation (MR), but mitral transcatheter edge-to-edge valve repair (M-TEER) is routinely performed in patients at high surgical risk and is increasingly performed in intermediate risk patients. Methods: From 2010 to 2021, we performed 723 M-TEER and 123 isolated MIC-MVS procedures. We applied a sensitivity analysis by matching age, left ventricular ejection fraction (LVEF), EuroSCORE II and etiology of MR. Results: Baseline characteristics showed significant differences in the overall cohort (p < 0.01): age 78.3 years vs. 61.5 years, EuroSCORE II 5.5% vs. 1.3% and LVEF 48.4% vs. 60.4% in M-TEER vs. MIC-MVS patients. Grade of MR at discharge was moderate/severe in 24.5% (171/697) in M-TEER vs. 6.5% (8/123) in MIC-MVS (p < 0.01). One-year survival was 91.5% (552/723) in M-TEER vs. 97.6% (95/123) in MIC-MVS (p = 0.04). A matching with 49 pairs (n = 98) showed comparable survival during follow-up, but a numerically higher mean mitral valve gradient of 4.1 mmHg (95% CI: 3.6–4.6) vs. 3.4 mmHg (95% CI: 3.0–3.8) in M-TEER (p = 0.04). Conclusions: Patients undergoing M-TEER had lower one-year survival than MIC-MVS, but differences disappeared after matching. Reduction in MR was less effective in M-TEER patients and postprocedural mitral valve gradients were higher.