Mateja Nosil Mešić

Ms. Mateja Nosil Mešić

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2022 in Buildings
Verified
Journal Article
Open access
PDF file
ZVZoran Veršić
Zoran Veršić
MBMarin Binicki
Marin Binicki
MMMateja Nosil Mešić
Mateja Nosil Mešić
The envelope is one of the most important driving factors in the energy efficiency of buildings. Typical for office and commercial buildings, curtain wall facades allow solar heat gains to be used during the winter but can lead to difficulties in reducing the cooling load during summer. The cooling load is dominant in most building types in the temperate maritime climate, while in the temperate continental climate, it is dominant mainly in office and commercial buildings. The goal of this research was to determine the potential of night passive cooling in an office building model in the most populated urban areas in Croatia-Zagreb and Split, which are located in two different climate zones. Suitable to the climate on-site, an appropriate building envelope and various types of passive and mechanical ventilation systems were selected for each location and case. Additional factors included and analysed were climate conditions, heat gains, the heat accumulation of the building, night ventilation through openings, unwanted air infiltration, and cooling loads. Through a detailed description of the model, passive cooling potential calculations, and Computer Fluid Dynamics (CFD) simulations, the results showed a potential of up to 43.5% savings in the cooling energy need for the temperate continental climate and 32.2% in the temperate marine climate. It was found from the analysis that night ventilation is expected to cool down the building enough to delay a need for cooling by several hours and improve fresh air requirements, thus saving power for cooling, and effectively reducing the need for air conditioning.

9 August 2023 in Buildings
Verified
Journal Article
Open access
PDF file
ZVZoran Veršić
Zoran Veršić
MBMarin Binicki
Marin Binicki
MMMateja Nosil Mešić
Mateja Nosil Mešić
Josip GalicJosip Galic
Josip Galic
Although glass façades have been on the market for over a century, new improvements, following sustainable standards, are still being invented. An improvement of the actively maintained CCF has occurred in passive maintenance with natural ventilation of the cavity and insulation glass unit placed on the external side, which has served as a true motivation for further research. To develop the idea, a new type of CCF was invented, followed by the creation of the software, whose purpose is to determine optimal CCF façade components. During this research, an experimental and mathematical model was made regarding the thermal behavior, later validated by the measurements on-site in Rugvica, Croatia. Using simplified but unconventional methods, numerous formulae and variables, a simulation of climatic loads onto the CCF was conducted. Validations of the thermal model were made during winter and summer periods for southern and western façade orientation, explaining how heat transfers from the environment to close cavity façade elements. It was found from the analysis that air temperatures of the façade elements follow the outer air temperature, by constant air exchange with the outer space. The results showed great potential with up to 3 °C (5–10%) of difference in experimental and calculated results, thus creating a basis for further improvement of the software with the addition of structural and hygric behavior of the façade element, regarding climate conditions.

2 January 2026 in Buildings
Verified
Journal Article
Open access
PDF file
ZVZoran Veršić
Zoran Veršić
MBMarin Binički
Marin Binički
MMMateja Nosil Mešić
Mateja Nosil Mešić
The EPBD 2024 recast sets the deadline for new Zero-Emission Building standards for all new publicly owned buildings to 2028 and to 2030 for all new buildings. In the scope of Life Cycle Assessment stages, all steps resulting in major emissions from buildings must be considered and presented. The research evaluates the life cycle greenhouse gas emissions of a single-family house, focusing on diverse construction types and the hourly method of the annual energy calculations for continental and coastal climate areas in Croatia under the upcoming standards. Embodied carbon of diverse construction types was compared mutually, and required steps to meet the operational zero-emission standards were analyzed. Embodied energy of a 137.0 m2 family house built out of reinforced concrete results in up to 67 tons of CO2eq emissions, while wood in cross-laminated timber structures absorbs more carbon than emitted for all other materials and construction processes—23 tons of CO2eq. Regarding operational energy and accompanying emissions, in order to cost-effectively meet future ZEB standards in Croatia and offset the remaining operational emissions, photovoltaic systems of up to 2.5 kWp are required in continental areas and 1.6 kWp in coastal regions.

20 April 2026 in Acoustics
Verified
Journal Article
Open access
PDF file
MMMateja Nosil Mešić
Mateja Nosil Mešić
MHMarko Horvat
Marko Horvat
ZVZoran Veršić
Zoran Veršić
Diocletian’s palace with its cellars represents one of the most important cultural heritage sites of the ancient Roman civilisation on the present-day Croatian territory. The cellar complex has been rediscovered only recently and has been preserved remarkably well due to its centuries-long concealment beneath mediaeval urban matrices. An archaeoacoustic analysis was performed on a selected single-nave hall as a small part of this complex. A model of the hall was developed in room acoustics simulation software and calibrated based on the results of field measurements. Acoustic suitability of the hall for speech-based events and music performances was then evaluated according to contemporary objective criteria, and the findings were compared with the results of similar studies performed on other heritage sites. The hall was found to be very well suited for speech in terms of intelligibility and mid-frequency reverberation, thus showing potential for revitalisation, with excessive low-frequency reverberation in the hall and reduced audibility in the farthest part of the audience as potential issues. With a feasible audience size, the hall is not reverberant enough for music performances but provides high clarity. In terms of sound strength, the hall is suitable for solo performers or small ensembles. Excessive perceptive broadening of the sound source is expected due to strong early lateral energy. In terms of traditional Dalmatian a cappella singing, the acoustics of the hall are likely to support and enhance such performances.