Marko Horvat

Prof. Dr. Marko Horvat

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TOTin Oberman
Tin Oberman
Kristian JambrošićKristian Jambrošić
Kristian Jambrošić
MHMarko Horvat
Marko Horvat
Bojana Bojanic Obad ScitarociBojana Bojanic Obad Scitaroci
Bojana Bojanic Obad Scitaroci
This paper discusses the soundscape assessment approaches to soundscape interventions with musical features introduced to public spaces as permanent sound art, with a focus on the ISO 12913 series, Method A for data collection applied in a laboratory study. Three soundscape interventions in three cities are investigated. The virtual soundwalk is used to combine the benefits of the on-site and laboratory settings. Two measurement points per location were recorded—one at a position where the intervention was clearly perceptible, the other further away to serve as a baseline condition. The participants (N = 44) were exposed to acoustic environments (N = 6) recorded using the first-order Ambisonics microphone on-site and then reproduced via the second-order Ambisonics system in laboratory. A series of rank-based Kruskal–Wallis tests were performed on the results of the subjective responses. Results revealed a statistically significant positive effect on soundscape at two locations, and limitations related to sound source identification due to cultural factors and geometrical configuration of the public space at one location.

12 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
PFPetar Francek
Petar Francek
Kristian JambrošićKristian Jambrošić
Kristian Jambrošić
MHMarko Horvat
Marko Horvat
VPVedran Planinec
Vedran Planinec
Binaural synthesis with head tracking is often used in spatial audio systems. The devices used for head tracking must provide data on the orientation of the listener’s head. These data need to be highly accurate, and they need to be provided as fast and as frequently as possible. Therefore, head-tracking devices need to be equipped with high-quality inertial measurement unit (IMU) sensors. Since IMUs readily include triaxial accelerometers, gyroscopes, and magnetometers, it is crucial that all of these sensors perform well, as the head orientation is calculated from all sensor outputs. This paper discusses the challenges encountered in the process of the performance assessment of IMUs through appropriate measurements. Three distinct hardware platforms were investigated: five IMU sensors either connected to Arduino-based embedded systems or being an integral part of one, five smartphones across a broad range of overall quality with integrated IMUs, and a commercial virtual reality unit that utilizes a headset with integrated IMUs. An innovative measurement method is presented and proposed for comparing the performance of sensors on all three platforms. The results of the measurements performed using the proposed method show that all three investigated platforms are adequate for the acquisition of the data required for calculating the orientation of a device as the input to the binaural synthesis process. Some limitations that have been observed during the measurements, regarding data acquisition and transfer, are discussed.

1 May 2008 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
MHMarko Horvat
Marko Horvat
Kristian JambrošićKristian Jambrošić
Kristian Jambrošić
HDHrvoje Domitrovic
Hrvoje Domitrovic
As a part of an extensive ongoing research on reverberation time measurements, efforts have been made to find an impulse-like source that will comply with certain demands concerning its spectral content and sound pressure levels it can provide. Although the relevant standards state that such kind of sources should be avoided due to the lack of measurement repeatability, their use has proved to be necessary due to inability of conventional omni-directional loudspeakers to provide adequate sound pressure levels, especially at the low end of the frequency range of interest, thereby ensuring sufficient dynamic range. Therefore, the emphasis of this investigation has been made on peak sound pressure levels and the amount of low frequency content each source is able to provide. The investigated sources include 6 mm and 8 mm pistols, firecrackers with different amount of explosive compound and explosive mixtures of acetylene gas.

23 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VPVedran Planinec
Vedran Planinec
JRJonas Reijniers
Jonas Reijniers
MHMarko Horvat
Marko Horvat
HPHerbert Peremans
Herbert Peremans
Kristian JambrošićKristian Jambrošić
Kristian Jambrošić
The use of audio systems that employ binaural synthesis with head tracking has become increasingly popular, particularly in virtual reality gaming systems. The binaural synthesis process uses the Head-Related Transfer Functions (HRTF) as an input required to assign the directions of arrival to sounds coming from virtual sound sources in the created virtual environments. Generic HRTFs are often used for this purpose to accommodate all potential listeners. The hypothesis of the research is that the use of individual HRTF in binaural synthesis instead of generic HRTF leads to improved accuracy and quality of virtual sound source localization, thus enhancing the user experience. A novel methodology is proposed that involves the use of dynamic virtual sound sources. In the experiments, the test participants were asked to determine the direction of a dynamic virtual sound source in both the horizontal and vertical planes using both generic and individual HRTFs. The gathered data are statistically analyzed, and the accuracy of localization is assessed with respect to the type of HRTF used. The individual HRTFs of the test participants are measured using a novel and efficient method that is accessible to a broad range of users.

17 July 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DKDominik Kisić
Dominik Kisić
MHMarko Horvat
Marko Horvat
Kristian JambrošićKristian Jambrošić
Kristian Jambrošić
PFPetar Francek
Petar Francek
The pandemic of COVID-19 and the resulting countermeasures have made it difficult or impossible to perform listening tests in controlled laboratory environments. This paper examines the possibility of using speech for level calibration of sound reproduction systems used in listening tests performed in non-laboratory conditions, i.e., when such tests are distributed through the means of electronic communication and performed in a home environment. Moreover, a larger pool of potential test subjects can be reached in this manner. The perception of what the “normal” level of reproduced speech should be was examined through a listening experiment by letting the listeners set the level of reproduced speech samples as they saw fit, depending on the used sound reproduction system, the (non)existence of visual stimulus, and the voice of the speaker. The results show that the perception of normal speech level is highly individual when it comes to setting that level by listening to reproduced speech. The interindividual differences between the subjects are considerably larger than the impact of the three main effects. The understanding of what the “normal” level of read speech should be was examined experimentally as well by asking the subjects to read a paragraph of text, depending on the visual stimulus. The results show that the “normal” level of read speech is reasonably consistent and averages at 55 dBA at a normal conversational distance of 1 m, in a room with room acoustics conditions typical for home environment and low background noise, and with the visual stimulus that mimics the interlocutor put within the personal space of the reader. A preliminary proposal is given of a level calibration method for non-laboratory listening experiments based on these results, and some of its aspects that require further research are discussed.

25 April 2024 in Applied Acoustics
Verified
Journal Article
Closed access
MHMarko Horvat
Marko Horvat
KJKristian Jambrošić
Kristian Jambrošić
TZTamara Zaninović
Tamara Zaninović
TOTin Oberman
Tin Oberman