Abid Ali

Dr. Abid Ali

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2017 in IEEE Access
Verified
Journal Article
Open access
NNNursyarizal Mohd Nor
Nursyarizal Mohd Nor
AAAbid Ali
Abid Ali
TITaib Ibrahim
Taib Ibrahim
MRMohd Fakhizan Romlie
Mohd Fakhizan Romlie
Batteries are essential for efficiently utilizing the energy from the photovoltaic (PV) modules. However, integration of batteries with PV plants at large scale needs more attention in terms of size, location and times for the charging and discharging of the batteries. This paper addresses these aspects. It presents a Mixed Integer Optimization using Genetic Algorithm (MIOGA) for determining the optimum size and placement of Battery-Sourced Distributed Photovoltaic Generation (B-SDPVG) in distribution networks. The total energy loss index (TELI) is formulated as the main objective function and simultaneously, the bus voltage deviations and penetrations of the B-SDPVG are calculated. The yields from the PV plants are estimated using 15 years of weather data modeled with the aid of Beta Probability Density Function (Beta-PDF). Furthermore, a novel charge-discharge control model is developed for determining the choice of the charging and discharging of batteries at each hour. By considering different time varying voltage-dependent load models, the proposed algorithm is applied on IEEE 33 bus and IEEE 69 bus test distribution networks. The numerical results of two distribution networks with time-varying loads show the advantages of the proposed methodology. It was revealed that integration of battery storage and intelligent scheduling for charging and discharging of batteries produced much better results and improved the quality of distribution networks. The supply of power from the B-SDPVG during the peak load hours and at night was made possible for each load model. The proposed charge-discharge control model for scheduling the charging and discharging of the batteries was found dynamic. Results of this study can be of potential importance in planning for the integration of battery storage in distribution networks.

1 September 2017 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
AAAbid Ali
Abid Ali
NNNursyarizal bin MOHD NOR
Nursyarizal bin MOHD NOR
TITaib Ibrahim
Taib Ibrahim
Mohd Fakhizan  RomlieMohd Fakhizan Romlie
Mohd Fakhizan Romlie
The rate of integration of distributed generation (DG) using renewable sources is increasing in distribution networks because of their technical and economic advantages. However, mismatches in the timing of electricity demand and generation in distribution networks have restricted the penetration of non-dispatchable DGs such as photovoltaic (PV) plants. Such a problem associated with the integration of DGs in distribution networks could be eliminated using the proper application of battery energy storage systems. In this paper, optimal planning of battery-coupled distributed photovoltaic generators (BCDPGs) in distribution networks is presented. The optimal planning determines the size and location of BCDPGs and schedules the charging and discharging of the batteries, while minimizing the total energy losses subject to technical constraints. To estimate the output from PV modules, 15-year solar irradiance data is modeled using the beta probability density function. Mixed-integer optimization using a genetic algorithm is employed for solving the optimization problem. The numerical studies on a 33-node distribution network show the advantages of the proposed methodology. The results obtained through this study show the capability of the proposed method to optimally allocate BCDPGs to largely improve the quality of supply of power from non-dispatchable DGs in terms of reducing energy losses, improving bus voltages, and increasing penetration levels of renewable energy. The proposed approach can also be useful when applied to realistic networks for proper sizing and operations of battery-coupled photovoltaic plants.

1 March 2018 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
AAAbid Ali
Abid Ali
NNNursyarizal bin MOHD NOR
Nursyarizal bin MOHD NOR
TITaib Ibrahim
Taib Ibrahim
Mohd Fakhizan  RomlieMohd Fakhizan Romlie
Mohd Fakhizan Romlie
The integration of distribution generation (DG) in distribution networks with improper planning adversely influences the quality of the electrical networks. Conventionally, the outputs from the intermittent DGs, such as solar photovoltaic (PV) plants, are assumed dispatchable. The intermittency of solar irradiance on the outputs of the PV modules has been ignored in most studies on the sizing and placement of DGs. By looking at this problem, this paper presents the sizing and placement of a distributed solar photovoltaic plant (DSPP) by using time series historical weather data. To predict the output from the PV modules, 15 years of solar data were modeled with the aid of a beta probability density function. The total energy loss index was formulated as the main objective function, and the optimization problem was solved by mixed integer optimization by using genetic algorithm. By adopting a time-varying commercial load, the proposed algorithm was applied on IEEE 33 bus and IEEE 69 bus distribution networks. The numerical studies on the two distribution networks show the advantages of the proposed approach for minimizing the total energy losses and improving the bus voltage profiles. It was revealed that up to 38% of the total energy losses in distribution networks could be reduced at sites with solar insolation of 5.65 peaks sun hours. In contrast to existing methods, planning for DGs by using weather data provided more realistic results for DSPP in distribution networks.

15 September 2023 in Solar
Verified
Journal Article
Open access
PDF file
AAAbid Ali
Abid Ali
MVMaïté Volatier
Maïté Volatier
MDMaxime Darnon
Maxime Darnon
Despite abundant solar resources, Mali has remained one of the least electrified countries in the world. Besides daily life activities and the economy, the shortage of electricity has severely affected the quality of healthcare services in the country. In the absence of electrical grids, standalone photovoltaic (PV) systems could be an alternative option in Mali for the electrification of isolated community health centers. However, because standalone PV systems are highly weather-dependent, they must be properly sized according to the local weather conditions. This paper presents the optimal sizing of standalone PV systems for the electrification of community health centers in Mali. The optimization for PV systems was performed for five different locations through simulation and modeling using PVsyst, considering the autonomy of 1 to 3 days and the probability of loss of load for 1 to 5%. Furthermore, for the economic analysis, the levelized cost of electricity (LCOE), payback period and return on investment for the standalone PV systems were calculated. Through the optimization, it was found that the standalone PV systems with PV array sizes ranging from 1650 to 2400 watts, along with 606 Ah battery storage, would be suitable to supply the daily energy demand for community health centers anywhere in the country. Moreover, by only replacing the 606 Ah battery storage with 1212 Ah and 1818 Ah sizes, the PV systems would be able to help and keep the energy reserves for 2 and 3 autonomous days, respectively. Furthermore, the results show that in comparison to a LCOE of 0.94–0.98 USD/kWh for a diesel generator, the LCOE for the standalone PV system would range from 0.23 to 0.46 USD/kWh without discounted rates and from 0.33 to 0.60 USD/kWh if discounted at 6%. In addition to a lower LCOE, the saving of 46–76 tons of CO2 during the project’s lifespan, the short payback periods and high return of investment (ROI) values make standalone PV systems a suitable electrification option for Mali. Considering the total expenses, LCOE, payback period, and ROI, standalone PV systems for community health centers were found to be economically viable in all cases for Mali.

19 April 2023 in Jurnal Teknologi (Sciences & Engineering)
Verified
Journal Article
Open access
PDF file
HJHanis Farhah Jamahori
Hanis Farhah Jamahori
PAPauzi Abdullah
Pauzi Abdullah
AAAbid Ali
Abid Ali
Most distributed renewable energy generation (DREG) planning studies are performed using a constant load model and a dispatchable generation unit. However, the renewable generation unit and load demand vary in real life, and the generation size at the peak demand varies accordingly with loading levels. Such considerations may lead to the erroneous conclusion: the power loss reduction and bus voltage improvement may not be optimal. Consequently, the generation unit must be adequately integrated to offer optimal capacity in the distribution system while considering non-constant load demand as a part of DREG planning. Therefore, the impact of integrating photovoltaic (PV) considering historical solar weather data and varying load demand for five different voltage-dependent load models is proposed in this study. Particle swarm optimization (PSO) is employed to find the optimal location and size of PV with the objective to minimize power losses in the distribution system using IEEE 33-bus and IEEE 69-bus test systems. The findings are evaluated based on the comparative analysis of power losses reduction, PV penetration level, power loss index, and voltage deviation index. Findings revealed that the proposed model is effective in determining the optimal location and size of PV with a significant reduction of power losses that varies between 13.84% to 32.71% in 33-bus, and between 18.56% to 43.80% in 69-bus. In addition, the improvement in minimum bus voltage and other performance indices are also significant.

1 January 2018
Verified
Conference Paper
Closed access
AAAbid Ali
Abid Ali
MRM.F. Romlie
M.F. Romlie
NNN.M. Nor
N.M. Nor
TIT. Ibrahim
T. Ibrahim
The integration of distributed generators (DGs) considering renewable energy provides great benefits to the distribution networks, such as, reductions in power loss and improvements of voltage profile. However, such benefits to the distribution networks are constrained with the installation of DGs with proper sizes and locations. In this paper, the optimization for sizing and placement of distributed renewable generators (DRGs) in the electrical distribution networks is presented. The optimum sizes and locations for the DRGs are determined to reduce the power loss in the distribution networks. The genetic algorithm (GA) has been used to solve the optimization problem using MATLAB. For the validation, results of this study are compared with other well-known heuristic optimization techniques and analytical approaches. The numerical studies on the IEEE 33 bus distribution network have revealed that the proposed algorithm is capable for finding the optimum size and place of DRG in the distribution networks. The optimization results using GA are seen very competitive with the result by other well-known heuristic optimization techniques and analytical approaches that have been used for the similar studies. The results from this study signify the use of GA in the research related to planning of renewable energy and power system.