Lingfeng Tang

Lingfeng Tang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2022 in Machines
Verified
Journal Article
Open access
PDF file
ZXZhenFa Xu
ZhenFa Xu
FKFanyu Kong
Fanyu Kong
LTLingfeng Tang
Lingfeng Tang
YWYoumin Wang
Youmin Wang
JWJiaqiong Wang
Jiaqiong Wang
Ning QiuNing Qiu
Ning Qiu
Blade thickness is an essential parameter of the impeller, which has significant effects on the pump performance. The plastic pump generally adopts thick blade due to low strength of plastic. The effects of blade thickness on the internal flow and performance of a plastic centrifugal pump were discussed based on the numerical methods. Two kinds of blade profile, the constant thickness blade (CTB) and the variable thickness blade (VTB), were investigated. The results indicated that, for the CTB, when the blade thickness was less than 6 mm, the pump performance did not change significantly. When the blade thickness exceeded 6 mm, the pump head and efficiency decreased rapidly. The pump head and efficiency of CTB 10 decreased by 42.2% and 30% compared with CTB 4, respectively. For the VTB, with blade thickness in a certain range (6 mm–14 mm), the pump performance changed slightly with the increased of trailing edge thickness. The minimum blade thickness of the plastic centrifugal pump should be 4 mm based on the finite element analysis. A variable thickness blade (VTB 4-8-4) with the maximum thickness located at 60% chord length was proposed to improve the pump performance, and its efficiency was 1.67% higher than that of the CTB 4 impeller.

16 August 2022 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
鲁王鲁 王
鲁 王
LTLingfeng Tang
Lingfeng Tang
PWPeng Wu
Peng Wu
JCJiaqi Chen
Jiaqi Chen
Plastic instead of steel technology is one of the important means of automotive lightweighting, which can greatly reduce the weight of the car while ensuring the same performance of the product. For the lightweighting of the automotive all-plastic front-end frame structure, the initial structural design of the front-end frame was carried out by HyperMesh; based on the compromise planning method and entropy weight method, the compromise planning method with weight coefficients was used to unify the planning of each subobjective to obtain the integrated response function, and the minimization of the integrated response function was the objective. The main considerations were the lock limit crash load, the cushion area load, and the pedestrian protection impact load under typical operating conditions, the shape optimization, and topology optimization, respectively. The mass of the sheet metal front-end frame was reduced from the original 10.5 kg to 6.8 kg—a weight reduction of 35.24%. The front-end frame was extracted and the mid-plane was repaired by HyperMesh, the complete mid-plane was meshed, loads and properties were added to the mesh, the front-end frame was subjected to static and modal analysis in the OptiStruct module, and the stiffness and intrinsic frequency were verified. The results show that the smallest first-order mode in the modal analysis is 57.38 Hz, which is much larger than the 30 Hz required before design. The fatigue analysis of the front-end frame was then performed using N-code to derive the damage results; it is concluded that its life is 6122 s, much larger than the specified 1200 s. Through the verification of the relevant resonance test, it is judged that the performance of the test part meets the actual requirements comprehensively by checking the status after the test.

23 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZRZhi Rao
Zhi Rao
LTLingfeng Tang
Lingfeng Tang
HZHui Zhang
Hui Zhang
Aiming at the problem of high vibration and high wear of centrifugal pump tongue, this paper proposes a double-tongue volute structure. Under the condition of ensuring the reliability of CFD results, the influence of various combinations of tongue and volute base circle on the turbulent kinetic energy of centrifugal pump and the radial force of impeller is explored. The traditional single-tongue volute centrifugal pump is compared with various characteristic indexes, and the unsteady numerical calculation is carried out based on different working conditions. It is concluded that the double-tongue volute structure can improve the pressure fluctuation at the monitoring points near the tongue. The results show that the double-tongue volute structure can improve the static pressure gradient and velocity gradient of the middle section of the centrifugal pump and reduce the maximum turbulent kinetic energy value at the tongue under small flow conditions. When the working condition is 1.0 Q, the radial force of the impeller of the C-type double-tongue volute reaches the minimum value of 3.03 N, which can effectively balance part of the radial force.

20 February 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LZLili Zhang
Lili Zhang
LTLingfeng Tang
Lingfeng Tang
QWQingzhao Wen
Qingzhao Wen
The inherent weakness in the deformation resistance of plastic centrifugal pumps makes them prone to vibrations. This study explores the impact of flow components on the vibrations of such pumps. Utilizing the given parameters, the primary structural parameters of the plastic centrifugal pump were calculated. The study focused on the torsional vibrations within the pump shaft transmission system, employing a silicone oil damper for vibration mitigation. A dual-mass forced torsion vibration model was developed for the pump shaft transmission system with the added damper. The optimal damping coefficient for this damper was determined, and its structural design was completed, including the creation of three-dimensional models and two-dimensional part drawings. Utilizing a ZT-3 type rotor test bench, a mathematical model correlating centrifugal pump speed with deflection was developed, and the effectiveness of various polynomials was assessed. The analysis showed that the optimal damping value for the silicone oil damper is 0.22. Compared to the system without the damper, the vibration frequency reduced by 10.45%, and the vibration amplitude decreased by 49.29%, demonstrating excellent vibration reduction effectiveness.

26 September 2022 in Journal of Engineering
Verified
Journal Article
Open access
PDF file
LZLili Zhang
Lili Zhang
LTLingfeng Tang
Lingfeng Tang
QWQingzhao Wen
Qingzhao Wen
WLWenbin Luo
Wenbin Luo
At present, the design of the pump shaft transmission system mostly refers to the design method of the metal pump transmission system. The dynamic and static characteristics of the plastic centrifugal pump are not related to the structural parameters of the pump shaft. Aiming at the influence of the structural parameters of the pump shaft transmission system on the dynamic and static performance of the plastic centrifugal pump, the three-dimensional model of the impeller and volute chamber was drawn by Creo5.0. The CFD calculation of the load of the plastic centrifugal pump was carried out. The flow field of the plastic centrifugal pump under ideal working conditions was simulated by ANSYS FLUENT. Combined with the application principle of singular function in mechanics, the mathematical model of a deflection of the pump shaft transmission system was constructed. Considering the minimum deflection and the maximum critical speed of the first order as the objective function, an optimization model of the structural parameters of the pump transmission system was established. The NSGA-II multiobjective optimization method was used to solve the optimal structural parameters of the optimization model, and the optimization design of the pump shaft span, cantilever, front, and rear bearing clearance was completed. The optimal span cantilever ratio of the rotor model of the single span cantilever structure was 1:0.75. Compared with the traditional design model, the optimized pump shaft deflection is reduced by 52.35%, and the first-order critical speed is increased by 42.77%. Simultaneously, using polynomial fitting as a mathematical tool, the experimental data were analyzed, and the mathematical expression of the rotation speed deflection relationship of the pump shaft at the first critical rotation speed and the corresponding function curve was obtained.

8 August 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZRZhi Rao
Zhi Rao
LTLingfeng Tang
Lingfeng Tang
YSYifang Shi
Yifang Shi
In light of the limitation that passive suspension can only provide vibration isolation within a specific range, a magnetorheological suspension in extrusion mode was developed. The reliability of structural parameters was ensured through theoretical analysis and numerical simulation, building upon traditional hydraulic suspension. A model linking static stiffness to the diameter of the upper extrusion plate, as well as the heights of the upper and lower liquid chambers, was established using Simulink as an evaluation index. The static stiffness performance of the magnetorheological suspension was then optimized using this model. Results indicate that while meeting the static stiffness requirements, the optimized Magnetorheological Suspension demonstrated a 29.22% increase in static stiffness (approximately 57.71 N/mm) compared to its previous state, validating the effectiveness of stiffness optimization for this system.