Florian Helms

Dr. Florian Helms

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2021 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
FHFlorian Helms
Florian Helms
SLSkadi Lau
Skadi Lau
TAThomas Aper
Thomas Aper
SZSarah Zippusch
Sarah Zippusch
MKMelanie Klingenberg
Melanie Klingenberg
UBUlrike Böer
Ulrike Böer

7 September 2023 in Medicina
Verified
Journal Article
Open access
PDF file
FHFlorian Helms
Florian Helms
BSBastian Schmack
Bastian Schmack
AWAlexander Weymann
Alexander Weymann
JHJasmin S. Hanke
Jasmin S. Hanke
RNRuslan Natanov
Ruslan Natanov
Aron-Frederik PopovAron-Frederik Popov
Aron-Frederik Popov
Minimally invasive techniques have gained immense importance in cardiovascular surgery. While minimal access strategies for coronary and mitral valve surgery are already widely accepted and often used as standard approaches, the application of minimally invasive techniques is currently expanded towards more complex operations of the ascending aorta as well. In this new and developing field, various techniques have been established and reported ranging from upper hemisternotomy approaches, which allow even extensive operations of the ascending aorta to be performed through a minimally invasive access to sternal sparing thoracotomy strategies, which completely avoid sternal trauma during ascending aorta replacements. All of these techniques place high demands on patient selection, preoperative planning, and practical surgical implementation. Application of these strategies is currently limited to high-volume centers and highly experienced surgeons. This narrative review gives an overview of the currently available techniques with a special focus on the practical execution as well as the advantages and disadvantages of the currently available techniques. The first results demonstrate the practicability and safety of minimally invasive techniques for replacement of the ascending aorta in a well-selected patient population. With success and complication rates comparable to classic full sternotomy, the proof of concept for minimally invasive replacement of the ascending aorta is now achieved.

4 May 2022 in Biotechnology and Bioengineering
Verified
Journal Article
Open access
FHFlorian Helms
Florian Helms
SZSarah Zippusch
Sarah Zippusch
JTJonathan Theilen
Jonathan Theilen
AHAxel Haverich
Axel Haverich
MWMathias Wilhelmi
Mathias Wilhelmi
UBUlrike Böer
Ulrike Böer
Facilitating sufficient nutrient and oxygen supply in large‐scale bioartificial constructs is a critical step in organ bioengineering. Immediate perfusion not only depends on a dense capillary network, but also requires integrated large‐diameter vessels that allow vascular anastomoses during implantation. These requirements set high demands for matrix generation as well as for in vitro cultivation techniques and remain mostly unsolved challenges up until today. Additionally, bioartificial constructs must have sufficient biomechanical stability to withstand mechanical stresses during and after implantation. We developed a bioartificial tissue construct with a fibrin matrix containing human umbilical vein endothelial cells and adipose tissue‐derived stem cells facilitating capillary‐like network formation. This core matrix was surrounded by a dense acellular fibrin capsule providing biomechanical stability. Two fibrin‐based macrovessels were integrated on each side of the construct and interconnected via four 1.2 mm thick microchannels penetrating the cellularized core matrix. After 4 days of perfusion in a custom‐built bioreactor, homogeneous capillary‐like network formation throughout the core matrix was observed. The fibrin capsule stabilized the core matrix and facilitated the generation of a self‐supporting construct. Thus, the encapsulated fibrin tissue construct could provide a universal prevascularized matrix for seeding with different cell types in various tissue engineering approaches.

24 October 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SASadeq Ali-Hasan-Al-Saegh
Sadeq Ali-Hasan-Al-Saegh
FHFlorian Helms
Florian Helms
KAKhalil Aburahma
Khalil Aburahma
STSho Takemoto
Sho Takemoto
NMNunzio Davide de Manna
Nunzio Davide de Manna
Alexander WeymannAlexander Weymann
Alexander Weymann
Background/Objectives: Over the past two decades, significant advancements in mitral valve surgery have focused on minimally invasive techniques. Some surgeons consider obesity as a relative contraindication for minimally invasive mitral valve surgery (MIMVS). The aim of this study is to evaluate whether the specific characteristics of obese patients contribute to increased surgical complexity and whether this, in turn, leads to worse clinical outcomes compared to non-obese patients. Furthermore, we aim to explore whether these findings could substantiate the consideration of limiting this treatment option for obese patients. We investigated the outcomes of MIMVS in obese and non-obese patients at a high-volume center in Germany staffed by an experienced surgical team well-versed in perioperative management. Methods: A total of 934 MIMVS were performed in our high-volume center in Germany from 2011 to 2023. Of these, 196 patients had a BMI of 30 or higher (obese group), while 738 patients had a BMI below 30 (non-obese group), all of whom underwent MIMVS by right minithoracotomy. Demographic information, echocardiographic assessments, surgical data, and clinical outcome parameters were collected for all patients. Results: There was no significant difference in in-hospital, 30-day, and late mortality between groups (obese vs. non-obese: 6 [3.0%] vs. 14 [1.8%], p = 0.40; 6 [3.0%] vs. 14 [1.8%], p = 0.40; 13 [6.6%] vs. 39 [5.3%], p = 0.48, respectively). Respiratory insufficiency and arrhythmia occurred more frequently in the obese group (obese vs. non-obese: 25 [12.7%] vs. 35 [4.7%], p < 0.001; 35 [17.8%] vs. 77 [10.4%], p = 0.006). Conclusions: Obesity was not associated with increased early or late mortality in patients undergoing MIMVS. However, obese patients experienced higher incidences of postoperative complications, including respiratory insufficiency, arrhythmias, delirium, and wound dehiscence. Nonetheless, a multivariate logistic regression analysis indicated that obesity itself does not contraindicate MIMVS and should not be viewed as a barrier to offering this minimally invasive approach to obese patients.

1 December 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
FHFlorian Helms
Florian Helms
AHAxel Haverich
Axel Haverich
UBUlrike Böer
Ulrike Böer
MWMathias Wilhelmi
Mathias Wilhelmi

23 September 2021 in Cardiovascular Engineering and Technology
Verified
Journal Article
Open access
PDF file
FHFlorian Helms
Florian Helms
AHAxel Haverich
Axel Haverich
MWMathias Wilhelmi
Mathias Wilhelmi
UBUlrike Böer
Ulrike Böer
Purpose: In vitro stimulation of native and bioartificial vessels in perfusable systems simulating natural mechanical environments of the human vasculature represents an emerging approach in cardiovascular research. Promising results have been achieved for applications in both regenerative medicine and etiopathogenetic investigations. However, accurate and reliable simulation of the wide variety of physiological and pathological pressure environments observed in different vessels still remains an unmet challenge. Methods: We established a modular hemodynamic simulator (MHS) with interchangeable and modifiable components suitable for the perfusion of native porcine—(i.e. the aorta, brachial and radial arteries and the inferior vena cava) and bioartificial fibrin-based vessels with anatomical site specific pressure curves. Additionally, different pathological pressure waveforms associated with cardiovascular diseases including hyper- and hypotension, tachy- and bradycardia, aortic valve stenosis and insufficiency, heart failure, obstructive cardiomyopathy and arterial stiffening were simulated. Pressure curves, cyclic distension and shear stress were measured for each vessel and compared to ideal clinical pressure waveforms. Results: The pressure waveforms obtained in the MHS showed high similarity to the ideal anatomical site specific pressure curves of different vessel types. Moreover, the system facilitated accurate emulation of physiological and different pathological pressure conditions in small diameter fibrin-based vessels. Conclusion: The MHS serves as a variable in vitro platform for accurate emulation of physiological and pathological pressure environments in biological probes. Potential applications of the system include bioartificial vessel maturation in cardiovascular tissue engineering approaches as well as etiopathogenetic investigations of various cardiovascular pathologies.