Jasmin S. Hanke

Dr. Jasmin S. Hanke


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2021 in Artificial Organs
Verified
Journal Article
Open access
PDF file
SMSilvia Mariani
Silvia Mariani
LNL. Christian Napp
L. Christian Napp
KKKarin Kraaier
Karin Kraaier
TLTong Li
Tong Li
KBKarl Bounader
Karl Bounader
RLRoberto Lorusso
Roberto Lorusso
Acute hemodynamic decompensation (AHD) during ventricular tachycardia (VT) ablation occurs in about 11% of cases. Prophylactic use of temporary mechanical circulatory support (pro‐tMCS) has been applied to prevent AHD during VT ablation, but evidence supporting this practice is still lacking. This systematic review and meta‐analysis assessed the procedural characteristics and outcomes of pro‐tMCS for VT ablation. PubMed/Medline was screened until February 2020. Articles including adults receiving pro‐tMCS for VT ablation were included, and a meta‐analysis to compare proMCS and no‐tMCS was performed. Primary outcome was in‐hospital/30‐day mortality. Five observational studies presenting 400 procedures (pro‐tMCS: n = 187; no‐tMCS: n = 213) were included. Baseline characteristics were comparable between groups. Impella and TandemHeart were used in 86.6% and 13.4% of cases, respectively. In the pro‐tMCS group, more VTs were induced (mean difference: 0.52, confidence interval [CI]: 0.26‐0.77, P < .0001), and patients remained in VT on average for 24.04 minutes longer (CI: 18.28‐29.80, P < .00001). Procedural success was comparable between groups, as was VT recurrence. Pro‐tMCS patients had an odds ratio of 0.55 (CI: 0.28‐1.05, P = .07) for in‐hospital/30‐day mortality and 0.55 (CI: 0.32‐0.94, P = .03) for mortality at follow‐up. Sixty‐four percent of no‐tMCS patients received rescue tMCS. The most common tMCS‐related complications were bleeding events. Pro‐tMCS allowed for a prolonged time on VTs and the induction of more VTs. Although these advantages were not associated with differences in procedural success, VT recurrence, or in‐hospital/30‐day mortality in the overall population, pro‐tMCS might improve long‐term survival. Further prospective studies are urgently needed to confirm these results.

1 April 2015 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
JHJasmin S. Hanke
Jasmin S. Hanke
Sebastian V. RojasSebastian V. Rojas
Sebastian V. Rojas
AMAndreas Martens
Andreas Martens
JSJan D. Schmitto
Jan D. Schmitto

23 July 2018 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
JHJasmin S. Hanke
Jasmin S. Hanke
JRJulia Riebandt
Julia Riebandt
MWMiena Wahabzada
Miena Wahabzada
FNFatma Nur
Fatma Nur
AWAngela Wahabzada
Angela Wahabzada
JSJan D. Schmitto
Jan D. Schmitto

1 May 2016 in Current Opinion in Cardiology
Verified
Journal Article
Closed access
Sebastian V. RojasSebastian V. Rojas
Sebastian V. Rojas
JHJasmin S. Hanke
Jasmin S. Hanke
AHAxel Haverich
Axel Haverich
JSJan D. Schmitto
Jan D. Schmitto
Ventricular assist device (VAD) therapy is currently one of the fastest-developing fields in cardiac surgery. Consistently improved technology, research, and gain of clinical experience have established VADs as an important option for the treatment of congestive heart failure. During the past year, novel devices and less invasive surgical procedures have been revolutionizing this field. The purpose of this manuscript is to review these innovations with special emphasis on device-related surgery.Device miniaturization has enabled less invasive VAD surgery, excluding the need for full sternotomy. Recent data show that intrahospital survival rates following less invasive VAD implantation are surpassing 90%. Secondly, two new devices, Heartmate 3 and MVAD, are being applied and tested for clinical application. In this context, the Heartmate 3 CE mark study recently concluded with excellent outcomes and without any pump thrombosis or device malfunctions.The first clinical results of the newest generation of VADs are very promising compared with old-generation devices. Furthermore, less invasive surgery is becoming a standard for the implantation, exchange, or explantation of left VADs. The joint venture of improved technology and innovative surgical techniques will push this field forward to even better outcomes and reduced complication rates.

30 March 2016 in The Journal of Heart and Lung Transplantation
Verified
Journal Article
Closed access
PDF file
JHJasmin S. Hanke
Jasmin S. Hanke
AHAxel Haverich
Axel Haverich
JSJan D. Schmitto
Jan D. Schmitto

8 October 2022 in Artificial Organs
Verified
Journal Article
Open access
AMAli Saad Merzah
Ali Saad Merzah
JHJasmin S. Hanke
Jasmin S. Hanke
TLTong Li
Tong Li
FMFadi A. Saad Merzah
Fadi A. Saad Merzah
MGMaria Gabriel
Maria Gabriel
GDGünes Dogan
Günes Dogan
Background: Driveline (DL) damages are a common difficulty among ventricular assist devices (VAD). Repairing the electrical fibers inside the DL on a running pump is hazardous and requires technical expertise, which is not easily available on site. A new feature of the HeartMate3 (Abbott, U.S.A.) LVAD is a modular driveline that allows an easy exchange of the DL cord. In this report we analyze our experiences with this feature.Methods: We performed a retrospective analysis of 302 patients who underwent either HeartMate II or HeartMate 3 implantation between February 2004 and September 2021. Patients were screened for driveline faults and need for exchange or repair of driveline or VAD exchange. Documented were baseline characteristics, reasons for DL or VAD exchange, and complications. Follow‐up was three months after the procedure.Results: We present a cohort of 302 patients who underwent either HMII (n = 107;35.4%) or HM 3 (n = 195; 64.5%) implantation. Out of those, 40 patients (40/302; 13.2%) required driveline repair (DLRe) or exchange (DLEx). Out of 107 HMII patients, 9 showed severe DL damages (9/107; 8.4%). Six patients (6/9; 66.6%) underwent DLRe, two patients (2/6; 33.3%) required VAD exchange after DLRe, one patient (1/2;50%) experienced emergency VAD exchange after pump stop. The DLRe procedure in the other four patients (4/6; 66.6%) was successful. Due to damage to the internal driveline two patients (2/9; 22.2%) underwent emergency device exchange and one patient (1/9;11.1%) was listed for transplantation. 31 out 195 HM3 patients underwent exchange of the modular DL. In none of the cases, damages of the internal fibers were the reasons for the exchange. In 100% of the cases, damages of the external coating were the reason for DL exchange. In none of the cases, complications occurred after the exchange procedure.Conclusions: Driveline damages are a habitual, recurrent complication in VAD patients. The exchange of the modular driveline cable of the HM3 is feasible and safe compared to the conventional DL repair in HMII patients. Risky repair attempts and surgical LVAD exchange due to major damages of the electrical fibers can be avoided successfully by the new feature of HM3 driveline.