Spyridon Mitropoulos

Mr. Spyridon Mitropoulos

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2025 in Electronics
Verified
Journal Article
Open access
PDF file
IGIoannis Georgantas
Ioannis Georgantas
SMSpyridon Mitropoulos
Spyridon Mitropoulos
SKStylianos Katsoulis
Stylianos Katsoulis
ICIOANNIS CHRONIS
IOANNIS CHRONIS
ICIoannis Christakis
Ioannis Christakis
Water quality is crucial for public health, especially in areas with water scarcity, such as remote islands. Although reliable measuring devices are available, on-site manual testing, such as in water tanks, is still necessary. In order to determine the quality of drinking water, a set of measurements should be carried out automatically, at regular intervals and without delay, thus ensuring the monitoring of its suitability. In this research work, an integrated low-cost water quality monitoring system is presented. The proposed system consists of the monitoring stations and an information system. Each monitoring station includes a microcontroller and sensors, and is installed in the water reservoir, while the information system is used to capture, store, and visualize the measurement data. Data transmission is carried out over a long-range (LoRa) network, providing extensive coverage for receiving data from Internet of Things (IoT) devices. Additionally, linear and non-linear correction factors are proposed to improve the accuracy of measurements from low-cost sensors, resulting in more reliable data. In this way, the end users, such as local authorities or citizens, are given the possibility of immediate information on water quality via the web.

5 March 2025 in Magnetism
Verified
Journal Article
Open access
PDF file
Νikolaos ΜaniotisΝikolaos Μaniotis
Νikolaos Μaniotis
SMSpyridon Mitropoulos
Spyridon Mitropoulos
Nick VordosNick Vordos
Nick Vordos
Vassilis TsiantosVassilis Tsiantos
Vassilis Tsiantos
In this study, the role of blood perfusion in modulating the thermal response of tumors during magnetic nanoparticle hyperthermia was investigated through computational modeling. The thermal dissipation of 15 nm magnetite nanoparticles was estimated using micromagnetic simulations of their hysteresis loops under a magnetic field of 20 mT and a frequency of 100 kHz. These calculations provided precise energy loss parameters, serving as inputs to simulate the temperature distribution in a tumor embedded within healthy tissue. Temperature-dependent blood perfusion rates, derived from experimental models, were integrated to differentiate the vascular dynamics in normal and cancerous tissues. The simulations were conducted using a bioheat transfer model on a 2D axisymmetric tumor geometry with magnetite nanoparticles dispersed uniformly in the tumor volume. Results showed that tumor tissues exhibit limited blood perfusion enhancement under hyperthermic conditions compared to healthy tissues, leading to localized heat retention favorable for therapeutic purposes. The computational framework validated these findings by achieving therapeutic tumor temperatures (41–45 °C) without significant overheating of surrounding healthy tissues, highlighting the critical interplay between perfusion and energy dissipation. These results demonstrate the efficacy of combining nanoparticle modeling with temperature-dependent perfusion for optimizing magnetic nanoparticle-based hyperthermia protocols.

22 February 2025 in Electronics
Verified
Journal Article
Open access
PDF file
SMSpyridon Mitropoulos
Spyridon Mitropoulos
DRDimitrios Rimpas
Dimitrios Rimpas
SKStylianos Katsoulis
Stylianos Katsoulis
George HloupisGeorge Hloupis
George Hloupis
ICIoannis Christakis
Ioannis Christakis
Manual intravenous (IV) monitoring delays, put patients at risk, as the reaction time of nursing staff can be critical to the patient’s health. The widespread use of LoRa networks today is a reality. The deployment of devices and applications based on LoRa networks in healthcare environments, such as hospital facilities, is of great interest and can offer both time savings for medical and nursing staff and improvements in medical care. In this work an integrated low-cost, real-time monitoring system for fluid infusion based on a LoRa network is presented. The measured (monitoring) data are the weight of the fluid infusion flask and the number of fluid drops. The design of the system and the affordability of the materials (low-cost devices) give the possibility for immediate application in healthcare environments. As the system consists of low-cost sensors, and given that it is intended for health purposes, extensive research has been carried out on the evaluation and reliability of the measurements. The proposed system is intended for medical care; in this sense it should have the lowest possible measurement error. The evaluation of the system has revealed a polynomial equation as a corrective factor for weight and shows an improvement of the error from 2% of the raw measurements to 0.6% of the corrected measurements, while regarding the calculation of the weight from the measurement of the droplets, it shows an error of 1.6%. The proposed system contributes directly to both the valuable time of the medical staff and the improvement of patient care. The evolution of technology should be applied to the health sector and low-cost and internet of things (IoT) devices can be applied to healthcare after thorough evaluation and calibration procedures.

15 November 2023 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
SMSpyridon Mitropoulos
Spyridon Mitropoulos
VOVassilios Athanassios Orfanos
Vassilios Athanassios Orfanos
DRDimitrios Rimpas
Dimitrios Rimpas
ICIoannis Christakis
Ioannis Christakis
As the use and development of Internet of Things is very popular nowadays, one of the most widespread ways of exchanging data from such arrangements is the use of the LoRa network. One of the advantages offered by this technology is the ability to provide low power consumption as well as wide wireless coverage in an area. Although in research, there are references regarding the coverage radius of a geographical area, differences can be detected between urban (cities) and rural (countryside) areas, as in the latter, there are no dense structures nor radio signal noise inside the operating frequency spectrum of LoRa. Thus, results are expected to be better in rural areas than urban areas. Especially in an urban area, apart from the signal noise caused by other LoRa devices (either commercial or private), the coverage varies according to the placement of the LoRa station inside a building, which is related to the height at which the gateway is placed in another building. In this work, the LoRa radio coverage study is presented in a radius of 2 km both in an urban and a rural environment using only one LoRa gateway. To better capture the coverage, LoRa stations are placed on every floor of the selected buildings periodically. The results show the difference in coverage between urban and rural areas which is related to radio signal noise. Furthermore, significant changes in the coverage map in urban areas can be observed, directly related to the installation height of the LoRa station. With the understanding of these variations in LoRa network performance in different environments, informed decisions can be made regarding the deployment of such networks, optimizing their efficiency and ensuring seamless data transmission in both urban and rural settings.

26 November 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
SMSpyridon Mitropoulos
Spyridon Mitropoulos
PCP. Chalkiadakis
P. Chalkiadakis
ICIoannis Christakis
Ioannis Christakis
In recent years, advances in both technology and medicine have made great progress. With the development of technology, low-cost and high-precision sensors have emerged and microcontrollers with high computing power and low power consumption have been created. In densely populated urban areas, health care is provided by a set of hospitals and medical centers where every patient can find an immediate response to their health concerns. However, medical care, particularly in non-urban areas, remains limited as many such areas do not have a hospital or medical center nearby. This results in inadequate medical care, both diagnostic and preventive, for the inhabitants of these areas. Today, the development of microprocessors, high-speed internet, and the low-cost sensors that have been developed can enable the creation of autonomous, accessible health monitoring units. In this work, an integrated low-cost, wearable electrocardiograph system is presented. The system is able to operate wherever there is an active internet connection. The proposed system consists of two parts. Firstly, the wearable ECG which can be located in the patient’s home. Secondly, the information system, in which the data from wearable ECG are collected and visualized, so that the doctor has direct access to the patient’s condition. Health is a precious commodity, and the application of technology is imperative, especially for the health care of citizens in remote areas.

6 January 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Νikolaos ΜaniotisΝikolaos Μaniotis
Νikolaos Μaniotis
SMSpyridon Mitropoulos
Spyridon Mitropoulos
Vassilis TsiantosVassilis Tsiantos
Vassilis Tsiantos
In this study, the role of blood perfusion in modulating thermal response of tumors during magnetic nanoparticle hyperthermia was investigated through computational modeling. The thermal dissipation of 15 nm magnetite nanoparticles was estimated using micromagnetic simulations of their hysteresis loops under a magnetic field of 20 mT and frequency of 100 kHz. These calculations provided precise energy loss parameters, serving as inputs to simulate the temperature distribution in a tumor embedded within healthy tissue. Temperature-dependent blood perfusion rates, derived from experimental models, were integrated to differentiate the vascular dynamics in normal and cancerous tissues. The simulations were conducted using a bioheat transfer model on a 2D axisymmetric tumor geometry with magnetite nanoparticles dispersed uniformly in the tumor volume. Results showed that tumor tissues exhibit limited blood perfusion enhancement under hyperthermic conditions compared to healthy tissues, leading to localized heat retention favorable for therapeutic purposes. The computational framework validated these findings by achieving therapeutic tumor temperatures (41–45°C) without significant overheating of surrounding healthy tissues, highlighting the critical interplay between perfusion and energy dissipation. These results demonstrate the efficacy of combining nanoparticle modeling with temperature-dependent perfusion for optimizing magnetic nanoparticle-based hyperthermia protocols.