Fen Li

Fen Li


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
FLFen Li
Fen Li
YZYating Zhu
Yating Zhu
HSHui Song
Hui Song
HZHongpeng Zhang
Hongpeng Zhang
LCLingfeng Chen
Lingfeng Chen
WGWei Guo
Wei Guo
The modular inner branched stent-graft (MIBSG), a novel interventional therapy, has demonstrated good effects in the endovascular treatment of aortic arch pathologies, especially those involving the supra-aortic branches. Nevertheless, the long-term efficacy of the MIBSG and in-depth quantitative evaluation of postoperative outcomes remain to be examined. Moreover, the regularity of postoperative vascular remodeling induced by MIBSG implantation has yet to be explored. To address these questions, we constructed four models (normal, preoperative, 1 week postoperative, and 6 months postoperative) based on a single patient case to perform computational fluid dynamics simulations. The morphological and hemodynamic characteristics, including the velocity profile, flow rate distribution, and hemodynamic parameter distribution (wall shear stress and its derivative parameters), were investigated. After MIBSG implantation, the morphology of the supra-aortic branches changed significantly, and the branch point moved forward to the proximal ascending aorta. Moreover, the curvature radius of the aortic arch axis continued to change. These changes in morphology altered the characteristics of the flow field and wall shear stress distribution. As a result, the local forces exerted on the vessel wall by the blood led to vessel remodeling. This study provides insight into the vascular remodeling process after MIBSG implantation, which occurs as a result of the interplay between vascular morphological characteristics and blood flow characteristics.

24 August 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
YZYawei Zhao
Yawei Zhao
YSYike Shi
Yike Shi
YJYusheng Jin
Yusheng Jin
YCYifan Cao
Yifan Cao
HSHui Song
Hui Song
WCWeiyi Chen
Weiyi Chen
Background: Moderate renal artery stenosis (50–70%) may lead to uncontrolled hypertension and eventually cause irreversible damage to renal function. However, the clinical criteria for interventional treatment are still ambiguous in this condition. This study investigated the impact of the position and degree of renal artery stenosis on hemodynamics near the renal artery to assess the short-term and long-term risks associated with this disease. Methods: Calculation models with different degrees of stenosis (50%, 60%, and 70%) located at different positions in the right renal artery were established based on the computed tomography angiography (CTA) of a personalized case. And computational fluid dynamics (CFD) was used to analyze hemodynamic surroundings near the renal artery. Results: As the degree of stenosis increases and the stenosis position is far away from the aorta, there is a decrease in renal perfusion. An analysis of the wall shear stress (WSS)-related parameters indicated areas near the renal artery (downstream of the stenosis and the entrance of the right renal artery) with potential long-term risks of thrombosis and inflammation. Conclusion: The position and degree of stenosis play a significant role in judging short-term risks associated with renal perfusion. Moreover, clinicians should consider not only short-term risks but also independent long-term risk factors, such as certain regions of 50% stenosis with adequate renal perfusion may necessitate prompt intervention.

10 February 2024 in Research on Chemical Intermediates
Verified
Journal Article
Open access
PDF file
YLYiping Li
Yiping Li
SWShile Wang
Shile Wang
XZXudong Zhu
Xudong Zhu
HYhong yan
hong yan
FLFen Li
Fen Li
With the rapid development of economy and society and the rapid advancement of industrialization and urbanization, the sewage discharged in the daily life of urban residents and the wastewater produced by industrial enterprises contain a large number of organic pollutants. Such organic pollutants are easy to flow into urban rivers through surface water, causing serious pollution of water environment, and thus adversely affecting the sustainable green development of cities. In recent years, the degradation of rhodamine B (Rh B) wastewater has become the focus of research on the treatment of refractory organic wastewater. In this paper, alkaline lignin was used as the precursor, and CQDs with fluorescence effect were prepared from bottom to top by hydrothermal method; Bi2WO6 was combined with Bi2WO6, and Bi2WO6/CQDs composite material was prepared to degrade organic pollutants into low-toxicity or non-toxic small molecules, as an effective way to solve the pollution of solar energy resources and environment. Carbon quantum dots (CQDs) have the advantages of excellent electron conduction and optical properties, non-toxicity and good biocompatibility, which will be more conducive to improving the light utilization rate of Bi2WO6 and inhibiting the recombination of electrons and holes, so as to improve its photocatalytic performance. The composite materials were characterized by XRD, FT-IR, TEM, and UV–Vis, and the results confirmed the successful preparation of Bi2WO6/CQDs using a simple hydrothermal method. The introduction of CQDs can reduce the bandgap width of Bi2WO6, thereby improving the absorption of light and promoting photogenerated electron transfer. Under visible light irradiation (300-W xenon lamp, λ > 420 nm), the amount of CQDs was 30 ml, and the degradation rate of Rh B was 86.96% within 120 min. Due to the excellent upconversion photoluminescence, as well as the photoinduced electron transfer and reservoir properties of CQDs, the Bi2WO6/CQDs composite exhibited superior photocatalytic performance in the degradation of Rh B under the irradiation of simulated solar light. This study provides a strategy for the development of high-performance catalysts based on CQDs.

1 January 2013 in Acta Physico-Chimica Sinica
Verified
Journal Article
Open access
PDF file
HSHui Song
Hui Song
XXXu Xianzhi
Xu Xianzhi
FLFen Li
Fen Li

20 November 2023 in Cardiovascular Engineering and Technology
Verified
Journal Article
Closed access
PDF file
YXYanqing Xie
Yanqing Xie
YZYating Zhu
Yating Zhu
YSYike Shi
Yike Shi
YZYawei Zhao
Yawei Zhao
HZHongpeng Zhang
Hongpeng Zhang
WGWei Guo
Wei Guo

3 April 2026 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
FLFen Li
Fen Li
HZHongpeng Zhang
Hongpeng Zhang
ZDZhuoxin Deng
Zhuoxin Deng
HSHui Song
Hui Song
WGWei Guo
Wei Guo
HTHaiping Tian
Haiping Tian
Purpose: To evaluate the hemodynamic performance and clinical implications of the WeFlow-Tribranch modular endograft system using patient-specific computational fluid dynamics (CFD) analysis. Methods: Pre- and postoperative CTA data sets from 3 patients treated with the WeFlow-Tribranch system were used to reconstruct 3-dimensional aortic models. CFD simulations were performed to compare changes in blood flow patterns, branch perfusion, and wall shear stress (WSS) parameters. The analysis focused on clinical metrics including branch perfusion distribution and hemodynamic markers associated with thrombus risk (TAWSS: time-averaged wall shear stress, OSI: oscillatory shear index, and RRT: relative residence time). Results: In the 3 analyzed cases, postoperative simulations showed that the device successfully restored more organized flow patterns in the aortic arch and effectively excluded aneurysms. Perfusion to the left common carotid artery (LCCA) improved in all 3 cases (+13% to +56%). However, perfusion to the brachiocephalic trunk (BCT) and left subclavian artery (LSA) varied substantially among the cases. Furthermore, simulations identified localized regions of low TAWSS and high OSI within the reconstructed branch tunnels, indicating potential sites for flow stagnation despite improvements in the main aortic flow. Conclusion: This preliminary CFD evaluation suggests that the WeFlow-Tribranch system has the potential to restore aortic arch hemodynamics and enhance LCCA perfusion in these specific cases. However, simulations indicated that the embedded branch design may compromise flow to the BCT or LSA in certain anatomical configurations, potentially inducing localized flow disturbances. These findings underscore the importance of patient-specific preoperative planning to anticipate perfusion changes and suggest that meticulous monitoring of branch patency is warranted. To fully evaluate its long-term performance and optimize its use, further studies involving larger patient cohorts and correlation with clinical outcomes are recommended. Clinical Impact: The WeFlow-Tribranch ™ system offers a modular, minimally invasive solution for complex aortic arch pathologies. This CFD study demonstrates that while the device restores organized aortic flow and improves LCCA perfusion, its embedded branch design introduces localized flow disturbances and patient-specific variations in BCT and LSA perfusion. For clinicians, these findings emphasize that anatomical feasibility alone is insufficient for patient selection. Meticulous pre-operative planning and rigorous post-operative surveillance of branch patency are essential to mitigate risks of thrombosis or ischemia induced by non-physiological wall shear stress.