Ivo Fridolin

Prof. Ivo Fridolin


Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Hypertension
Verified
Journal Article
Open access
PDF file
AVAntonia Vlahou
Antonia Vlahou
DHDara Hallinan
Dara Hallinan
RARolf Apweiler
Rolf Apweiler
AAAngel Argiles
Angel Argiles
JBJoachim Beige
Joachim Beige
Raymond VanholderRaymond Vanholder
Raymond Vanholder
The General Data Protection Regulation (GDPR) became binding law in the European Union Member States in 2018, as a step toward harmonizing personal data protection legislation in the European Union. The Regulation governs almost all types of personal data processing, hence, also, those pertaining to biomedical research. The purpose of this article is to highlight the main practical issues related to data and biological sample sharing that biomedical researchers face regularly, and to specify how these are addressed in the context of GDPR, after consulting with ethics/legal experts. We identify areas in which clarifications of the GDPR are needed, particularly those related to consent requirements by study participants. Amendments should target the following: (1) restricting exceptions based on national laws and increasing harmonization, (2) confirming the concept of broad consent, and (3) defining a roadmap for secondary use of data. These changes will be achieved by acknowledged learned societies in the field taking the lead in preparing a document giving guidance for the optimal interpretation of the GDPR, which will be finalized following a period of commenting by a broad multistakeholder audience. In parallel, promoting engagement and education of the public in the relevant issues (such as different consent types or residual risk for re-identification), on both local/national and international levels, is considered critical for advancement. We hope that this article will open this broad discussion involving all major stakeholders, toward optimizing the GDPR and allowing a harmonized transnational research approach.

1 August 2002 in The International Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
IFIvo Fridolin
Ivo Fridolin
MMM. Magnusson
M. Magnusson
LLL.-G. Lindberg
L.-G. Lindberg
Purpose: The aim of this work was to describe a new optical method for monitoring solutes in a spent dialysate using absorption of UV radiation. Method: The method utilises UV-absorbance determined in the spent dialysate using a spectrophotometrical set-up. Measurements were performed both on collected dialysate samples and on-line. During on-line monitoring, a spectrophotometer was connected to the fluid outlet of the dialysis machine, with all spent dialysate passing through a specially-designed cuvette for optical single-wavelength measurements. The concentrations of several substances of various molecular sizes, electrical charge, transport mechanism, etc. were determined in the dialysate and in the blood using standard laboratory techniques. The correlation coefficient between UV-absorbance of the spent dialysate and concentration of the substances in the spent dialysate and in the blood was calculated from data based on the collected samples. Results: The obtained on-line UV-absorbance curve demonstrates the possibility to follow a single hemodialysis session continuously and to monitor deviations in the dialysator performance using UV-absorbance. The experimental results indicate a very good correlation between UV-absorbance and several small waste solutes removed such as urea, creatinine and uric acid in the spent dialysate and in the blood for every individual treatment at a fixed wavelength of 285 nm. Moreover, a good correlation between the UV-absorbance and substances like potassium, phosphate and β2-microglobulin was obtained. The lowest correlation was achieved for sodium, calcium, glucose, vitamin B12 and albumin. Conclusions: A technique for on-line monitoring of solutes in the spent dialysate utilising the UV-absorbance was developed. On-line monitoring during a single hemodialysis session exploiting UV-absorbance represents a possibility to follow a single hemodialysis session continuously and monitor deviations in dialysis efficiency (e.g. changes in blood flow and clearance). The UV-absorbance correlates well to the concentration of several solutes known to accumulate in dialysis patients indicating that the technique can be used to estimate the removal of retained substances.

12 April 2006 in Nephrology Dialysis Transplantation
Verified
Journal Article
Open access
PDF file
FUFredrik Uhlin
Fredrik Uhlin
IFIvo Fridolin
Ivo Fridolin
MMMartin Magnusson
Martin Magnusson
LLLars-Göran Lindberg
Lars-Göran Lindberg
Background. An on-line monitoring system for dialysis dose calculations could make it possible to provide an adequate dialysis dose that is consistently given to haemodialysis (HD) patients. The aim of this study was to compare dialysis dose (Kt/V) using four different methods and their sensitiveness to a reduction in clearance. Methods. Six patients were monitored on-line with ultraviolet (UV)-absorbance at a wavelength of 297 nm in three consecutive dialysis sessions during 1 week. During the last treatment, the clearance was reduced by ∼25% by decreasing the blood flow. For the determination of UV-absorbance, a spectrophotometer was connected to the fluid outlet of the dialysis machine with all spent dialysate passing through a flow cuvette. The equilibrated Kt/V (eKt/V) estimated by UV-absorbance was compared with eKt/V from the ionic dialysance method using the on-line clearance monitor (OCM) and the appurtenant software dose-calculation tool DCTool (Fresenius Medical Care, Germany), eKt/V calculated from the dialysate-urea slope and with eKt/V from pre- and post-dialysis blood-urea samples as reference. Results. The study demonstrates that the sensitiveness to clearance reduction is similar in the four methods compared for eKt/V. When the different methods were compared, the mean eKt/V of UV-absorbance was 1.21 ± 0.20, blood 1.30 ± 0.21, dialysate 1.32 ± 0.21 and OCM (using the DCTool) 1.31 ± 0.21. The standard deviation was of the same magnitude. Conclusion. The UV-method gives a similar response to clearance reduction compared with the other methods when comparing dialysis dose. The high sampling rate by continuous monitoring of UV-absorbance allows evaluation of the clearance process during dialysis and gives immediate feedback to on-line adjustments.

1 May 2003 in American Journal of Kidney Diseases
Verified
Journal Article
Closed access
FUFredrik Uhlin
Fredrik Uhlin
IFIvo Fridolin
Ivo Fridolin
LLLars-Göran Lindberg
Lars-Göran Lindberg
MMMartin Magnusson
Martin Magnusson

18 October 2012 in Toxins
Verified
Journal Article
Open access
PDF file
JAJürgen Arund
Jürgen Arund
RTRisto Tanner
Risto Tanner
FUFredrik Uhlin
Fredrik Uhlin
IFIvo Fridolin
Ivo Fridolin
The aim of this work was to evaluate the contributions of the main chromophores to the total UV absorbance of the spent dialysate and to assess removal dynamics of these solutes during optical on-line dialysis dose monitoring. High performance chromatography was used to separate and quantify UV-absorbing solutes in the spent dialysate sampled at the start and at the end of dialysis sessions. Chromatograms were monitored at 210, 254 and 280 nm routinely and full absorption spectra were registered between 200 and 400 nm. Nearly 95% of UV absorbance originates from solutes with high removal ratio, such as uric acid. The contributions of different solute groups vary at different wavelengths and there are dynamical changes in contributions during the single dialysis session. However, large standard deviation of the average contribution values within a series of sessions indicates remarkable differences between individual treatments. A noteworthy contribution of Paracetamol and its metabolites to the total UV absorbance was determined at all three wavelengths. Contribution of slowly dialyzed uremic solutes, such as indoxyl sulfate, was negligible.

1 May 2003 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
IFIvo Fridolin
Ivo Fridolin
LLL. -G. Lindberg
L. -G. Lindberg