Fredrik Uhlin

Dr. Fredrik Uhlin


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2006 in Nephrology Dialysis Transplantation
Verified
Journal Article
Open access
PDF file
FUFredrik Uhlin
Fredrik Uhlin
IFIvo Fridolin
Ivo Fridolin
MMMartin Magnusson
Martin Magnusson
LLLars-Göran Lindberg
Lars-Göran Lindberg
Background. An on-line monitoring system for dialysis dose calculations could make it possible to provide an adequate dialysis dose that is consistently given to haemodialysis (HD) patients. The aim of this study was to compare dialysis dose (Kt/V) using four different methods and their sensitiveness to a reduction in clearance. Methods. Six patients were monitored on-line with ultraviolet (UV)-absorbance at a wavelength of 297 nm in three consecutive dialysis sessions during 1 week. During the last treatment, the clearance was reduced by ∼25% by decreasing the blood flow. For the determination of UV-absorbance, a spectrophotometer was connected to the fluid outlet of the dialysis machine with all spent dialysate passing through a flow cuvette. The equilibrated Kt/V (eKt/V) estimated by UV-absorbance was compared with eKt/V from the ionic dialysance method using the on-line clearance monitor (OCM) and the appurtenant software dose-calculation tool DCTool (Fresenius Medical Care, Germany), eKt/V calculated from the dialysate-urea slope and with eKt/V from pre- and post-dialysis blood-urea samples as reference. Results. The study demonstrates that the sensitiveness to clearance reduction is similar in the four methods compared for eKt/V. When the different methods were compared, the mean eKt/V of UV-absorbance was 1.21 ± 0.20, blood 1.30 ± 0.21, dialysate 1.32 ± 0.21 and OCM (using the DCTool) 1.31 ± 0.21. The standard deviation was of the same magnitude. Conclusion. The UV-method gives a similar response to clearance reduction compared with the other methods when comparing dialysis dose. The high sampling rate by continuous monitoring of UV-absorbance allows evaluation of the clearance process during dialysis and gives immediate feedback to on-line adjustments.

1 May 2003 in American Journal of Kidney Diseases
Verified
Journal Article
Closed access
FUFredrik Uhlin
Fredrik Uhlin
IFIvo Fridolin
Ivo Fridolin
LLLars-Göran Lindberg
Lars-Göran Lindberg
MMMartin Magnusson
Martin Magnusson

18 October 2012 in Toxins
Verified
Journal Article
Open access
PDF file
JAJürgen Arund
Jürgen Arund
RTRisto Tanner
Risto Tanner
FUFredrik Uhlin
Fredrik Uhlin
IFIvo Fridolin
Ivo Fridolin
The aim of this work was to evaluate the contributions of the main chromophores to the total UV absorbance of the spent dialysate and to assess removal dynamics of these solutes during optical on-line dialysis dose monitoring. High performance chromatography was used to separate and quantify UV-absorbing solutes in the spent dialysate sampled at the start and at the end of dialysis sessions. Chromatograms were monitored at 210, 254 and 280 nm routinely and full absorption spectra were registered between 200 and 400 nm. Nearly 95% of UV absorbance originates from solutes with high removal ratio, such as uric acid. The contributions of different solute groups vary at different wavelengths and there are dynamical changes in contributions during the single dialysis session. However, large standard deviation of the average contribution values within a series of sessions indicates remarkable differences between individual treatments. A noteworthy contribution of Paracetamol and its metabolites to the total UV absorbance was determined at all three wavelengths. Contribution of slowly dialyzed uremic solutes, such as indoxyl sulfate, was negligible.

3 December 2009 in Blood Purification
Verified
Journal Article
Closed access
JJJana Jerotskaja
Jana Jerotskaja
FUFredrik Uhlin
Fredrik Uhlin
IFIvo Fridolin
Ivo Fridolin
KLKai Lauri
Kai Lauri
MLMerike Luman
Merike Luman
AFAnders Fernström
Anders Fernström
This study estimates the total removal of uric acid (TRUA) by online UV absorbance measurements in the spent dialysate in two different dialysis centers in Estonia and Sweden. Sixteen dialysis patients were included. All dialysate was collected that gave the reference for TRUA. Two regression models were investigated: one for each patient (UV1) and one for the entire material (UV2). TRUA from the three methods was in the same order but showed a statistically significant difference when the UV2 model was built on data from both centers together. TRUA, (n = 56) was (mean ± SD, µmol): 5,854 ± 1,377 for reference, 6,117 ± 1,795 for UV1 and 5,762 ± 1,591 for UV2. Six patients were monitored 1 year after the first study session, using the same models as the previous year, still having a nonsignificant difference. The results show the possibility of estimating TRUA by using UV absorbance. The method appeared to be reliable also in long-term patient monitoring.

2 August 2005 in Nephrology Dialysis Transplantation
Verified
Journal Article
Open access
PDF file
FUFredrik Uhlin
Fredrik Uhlin
IFIvo Fridolin
Ivo Fridolin
LLLars-Göran Lindberg
Lars-Göran Lindberg
MMMartin Magnusson
Martin Magnusson
Background. Dialysate-based, on-line measurements of Kt/V and protein catabolic rate (PCR) in dialysis patients have been considered more accurate compared with measurements on the blood side during dialysis. The primary aim of this study was to compare total removed urea (TRU) and PCR, normalized to body weight (nPCRw), obtained by three dialysate-based methods: (i) on-line ultraviolet (UV) absorbance of the spent dialysate; (ii) total dialysate collection (TDC), as reference method; and (iii) Urea Monitor 1000 (UM) from Baxter Healthcare Corp. Methods. We studied 10 uraemic patients on chronic, thrice-weekly haemodialysis. We made absorption measurements (UV radiation) on-line with a spectrophotometer connected to the fluid outlet of the dialysis machine, with all spent dialysate passing through an optical cuvette for single-wavelength measurements. UV absorbance measurements were compared with TDC and the UM. Results. nPCRw obtained with UV absorbance was 0.82±0.17, that from TDC 0.81±0.18, and that measured by UM 0.87±0.18, which was significantly higher than the results of the other methods. The difference between nPCRw calculated by TDC and by UM was −0.05±0.06, showing a slightly lower SD than the difference between nPCRw by TDC and UV absorbance, −0.01±0.07. Conclusion. The study demonstrates that TRU, and consequently PCR, can be estimated by on-line measurement of the UV absorption in the spent dialysate.

12 October 2009 in Hemodialysis International
Verified
Journal Article
Closed access
PDF file
FUFredrik Uhlin
Fredrik Uhlin
JPJonas Pettersson
Jonas Pettersson
AFAnders Fernström
Anders Fernström
LLLars‐Göran Lindberg
Lars‐Göran Lindberg