Renato Rizzo

Prof. Renato Rizzo

Department of Electrical Engineering and Information Technologies, University of Naples Federico II, 80125 Naples, Italy

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2015 in Energies
Verified
Journal Article
Open access
PDF file
LPLuigi Piegari
Luigi Piegari
Renato RizzoRenato Rizzo
Renato Rizzo
ISIvan Spina
Ivan Spina
PTPietro Tricoli
Pietro Tricoli
The power extracted from PV arrays is usually maximized using maximum power point tracking algorithms. One of the most widely used techniques is the perturb & observe algorithm, which periodically perturbs the operating point of the PV array, sometime with an adaptive perturbation step, and compares the PV power before and after the perturbation. This paper analyses the most suitable perturbation step to optimize maximum power point tracking performance and suggests a design criterion to select the parameters of the controller. Using this proposed adaptive step, the MPPT perturb & observe algorithm achieves an excellent dynamic response by adapting the perturbation step to the actual operating conditions of the PV array. The proposed algorithm has been validated and tested in a laboratory using a dual input inductor push-pull converter. This particular converter topology is an efficient interface to boost the low voltage of PV arrays and effectively control the power flow when input or output voltages are variable. The experimental results have proved the superiority of the proposed algorithm in comparison of traditional perturb & observe and incremental conductance techniques.

1 September 2015 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
Gianluca BrandoGianluca Brando
Gianluca Brando
Adolfo DannierAdolfo Dannier
Adolfo Dannier
APAndrea Del Pizzo
Andrea Del Pizzo
Renato RizzoRenato Rizzo
Renato Rizzo
ISIvan Spina
Ivan Spina
This study deals with direct torque control (DTC) of induction motor drives when a multilevel inverter is involved. The proposed control technique is finalised to reduce the amplitude of torque oscillations and to improve the motor dynamic response regardless of operating speed conditions while assuring a satisfactory input current distortion. This is achieved by using a special look‐up‐table built with a novel approach. The control itself is based on the application in each sampling interval of one or two voltage vectors suitably selected, in order to ensure low electromagnetic torque ripple in steady‐state operations and fast dynamic behaviour in transient operations. In the algorithm, the converter voltage vectors selection is carried out by using a novel look‐up table whose entry points are computed by means of a specialised relation, starting from the outputs of multilevel hysteresis controllers. The suggested method, suitable for a generic multilevel inverter, is detailed for a neutral point clamped three‐level inverter. The proposed algorithm is validated by several numerical results, and compared with a DTC algorithm based on a traditional three‐speed range look‐up tables. Finally, some experimental results, obtained with a scale laboratory setup, are shown, discussed and compared with the numerical ones.

9 February 2018 in Energies
Verified
Journal Article
Open access
PDF file
FCFlavio Ciccarelli
Flavio Ciccarelli
Luigi Pio Di NoiaLuigi Pio Di Noia
Luigi Pio Di Noia
Renato RizzoRenato Rizzo
Renato Rizzo
The growing interest in the use of energy storage systems to improve the performance of tramways has prompted the development of control techniques and optimal storage devices, displacement, and sizing to obtain the maximum profit and reduce the total installation cost. Recently, the rapid diffusion of renewable energy generation from photovoltaic panels has also created a large interest in coupling renewable energy and storage units. This study analyzed the integration of a photovoltaic power plant, supercapacitor energy storage system, and railway power system. Random optimization was used to verify the feasibility of this integration in a real tramway electric system operating in the city of Naples, and the benefits and total cost of this integration were evaluated.

22 March 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Amedeo AndreottiAmedeo Andreotti
Amedeo Andreotti
APAlexandre Piantini
Alexandre Piantini
APAntonio Pierno
Antonio Pierno
Renato RizzoRenato Rizzo
Renato Rizzo
Recently, Andreotti et al. (2015) have presented a new tool for lightning induced voltage calculations on power networks. This tool, named CiLIV (Circuit for Lightning Induced Voltage), has been initially developed for straight and vertical lightning channels; afterwards, the tool has been extended to evaluate induced voltages produced by tortuous lightning channels. However, in the aforementioned studies, only simple power network configurations have been examined.

1 March 2019 in IET Electrical Systems in Transportation
Verified
Journal Article
Open access
PDF file
FCFrancesco Castelli-Dezza
Francesco Castelli-Dezza
VMVincenzo Musolino
Vincenzo Musolino
LPLuigi Piegari
Luigi Piegari
Renato RizzoRenato Rizzo
Renato Rizzo
Despite the yearly rise in the market quota of full electric vehicles, the main limitations on the deployment of electric vehicles are the real performances of the battery storage during operation. In this study, the authors focus on hybrid electrical storage systems composed of lead acid batteries and supercapacitors. Two different coupling methods are investigated: (i) the direct parallel coupling of the two storage devices and (ii) coupling by means of a step‐up converter between the supercapacitor bank and direct current (DC) link of the entire power‐train, where lead acid batteries are also connected. A specific control strategy is proposed and implemented in the step‐up converter to guarantee the correct power management of the power train and in particular: (i) to save the power request to the lead acid battery pack, (ii) maintain an adequate state of charge of the supercapacitor bank, and (iii) guarantee an adequate voltage level on the DC link. A prototype of the hybrid battery, integrating the proposed control technique, was realised and tested on a real forklift. The performances of the entire power‐train were experimentally measured in a warehouse test cycle emulating a typical daily working cycle.

10 January 2018 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
MRMircea Ruba
Mircea Ruba
FJFlorin JURCA
Florin JURCA
Levente CzumbilLevente Czumbil
Levente Czumbil
Dan MicuDan Micu
Dan Micu
CMClaudia Martis
Claudia Martis
Renato RizzoRenato Rizzo
Renato Rizzo
In this study, the design optimisation of a synchronous reluctance machine for light electric vehicles is proposed, to increase efficiency and reduce torque ripples. The existing machine was structurally optimised, using dedicated genetic algorithms, replacing only the rotor and keeping the stator and it's winding untouched. Starting from the original design of the rotor implemented in Flux2D, a finite element analysis software, and the genetic algorithm optimisation implemented in Matlab, a complex co‐simulation was accomplished to obtain a rotor architecture that increases the machine's performances and decreases the torque ripples. By this, performing rotor skewing is not needed any more, hence the torque loss due to it was cancelled. The optimised rotor design increases the machine performances by higher mean torque, no skewing, <8% torque ripples, higher efficiency and better inductance characteristics. Comparative results obtained both in simulations and experimental measurements prove positive outcomes of the optimisation process.