Mahmood H. Khaleel

Mr. Mahmood H. Khaleel


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in Journal of Thermal Engineering
Verified
Journal Article
Open access
PDF file
RARiyadh Husni Aljawad
Riyadh Husni Aljawad
AHAtif Ali Hasan
Atif Ali Hasan
MKMahmood H. Khaleel
Mahmood H. Khaleel
OZOmar Adil Zainal
Omar Adil Zainal
Due to the harsh climate in summer of the Iraq, the outer shell of buildings is exposed to heat flow from the outside ambient to the inside building space, and causes increase of heat gain in the space, so it requires the using of air conditioning units, which is led to consume electrical energy to remove that heat gain. The objective of this paper to reduce levels of electrical consumption by choosing best building materials. The best building materials which are those have good resistance against heat flow, that’s why the cost of building material difference each of other in the local market. While Aso Company for Bricks is considered one of the largest modern companies producing building materials and the most present in the entire area of Iraq. The aim of this study to focus was on its products, and five types models were selected and compared with the traditional model that is still used now. Therefore, heat gain test was experimentally conducted in a test room located in Baghdad city (zip code 10016, latitude of 33.2°N and longitude of 44°E) for one day from 6 a.m. to 7 p.m. and for the 21st day of each of the summer months (May to September) in 2021. The electrical energy consumed by the air-conditioning unit in the test room was measured, and the researchers concluded that the percentage of energy savings achieved within the limits (13.88–1.2%) depending on the type and thickness of the building material. Results shown the best building material is (Type IV), these blocks can be used to create walls with a thickness of 200 mm or 100 mm. Building blocks (the fourth kind), on the other hand, have a delay time of 6:30 hours and a thermal shrinkage coefficient of 0.63. They also have a density of 919 kg/m3. Therefore, the electrical consumption by A.C. units if used the blocks (Type IV) less than others.


21 January 2024 in Tikrit Journal of Engineering Sciences
Verified
Journal Article
Open access
PDF file
AHAtif Ali Hasan
Atif Ali Hasan
MKMahmood H. Khaleel
Mahmood H. Khaleel
KJKadhum Audaa Jehhef
Kadhum Audaa Jehhef
The study aims to reduce heat transfer in a building's conditioned space due to high environmental temperatures in the summer. The heat transfer through the building's external walls increases the need for electrical energy. This study developed four models to reduce heat transfer by covering the exterior wall of the building with perforated concrete blocks with holes, whose diameters varied within the range of 6–10 mm, distributed in three rows of variable hole diameter, each row containing three holes of equal diameter: Model A1 (the diameter of the three holes in the first row was 6 mm, and the diameter of the three holes in the second row was 8 mm, while the diameter of the three holes in the third row was 10 mm). Model A2: The hole arrangement with the sequence 10, 8, and 6 mm. Model B1: The hole arrangement was with the sequence 6, 10, and 8 mm. Model B2: The hole arrangement was with the sequence 8, 10, and 6 mm. The study examined the air gap between the building's covering blocks and the original wall. A thermal test room was built with an air conditioner and a cumulative electric energy meter to measure energy consumption. Perforated block models covered the test room's wall. Also, a numerical model was prepared using the ANSYS-Fluent package v. 16.2. The experimental and numerical results were consistent. Model B1 achieved higher electrical seasonal consumption than the conventional model, about 98.5 kilowatt-hours. While the other four models recorded low energy consumption, i.e., model A1 consumed 87.5 kilowatt-hours, with a reduction of 11.2%; model A2 consumed 83.9 kilowatt-hours, with a reduction of 15%; model B2 consumed 80 kilowatt-hours, with a reduction of 19%; and model B1 consumed 78 kilowatt-hours, with a reduction of 21%.

6 March 2025 in International Review of Applied Sciences and Engineering
Verified
Journal Article
Open access
PDF file
HOH. Obaidi
H. Obaidi
AHAtif A. Hasan
Atif A. Hasan
OZOmar Adil Zainal
Omar Adil Zainal
MKMahmood H. Khaleel
Mahmood H. Khaleel
Iraqi buildings consume high-level electrical energy for air conditioning purposes to provide the standard human comfort condition. This paper adopted an experimental study by using Styrofoam adhesive or white cement as an alternative to ordinary Portland cement to manufacture building blocks with dimensions of 200 × 200 × 200 mm containing an internal core with dimensions of 90 × 130 × 130 mm, which were filled by using corrugated scratch-up or closed air gap. The samples were divided into two sets: the first had an aluminium foil layer applied to the external surface of the samples (reflective surface), while the second was without any layer (ordinary surface). The samples were tested under the climatic conditions of Baghdad city during the summer months (May to September) of 2021. These blocks were also evaluated by different structural tests. It can be seen from the test results that the use of Styrofoam adhesive with a reflective surface with panels of corrugated scratch-up increased the thermal insulation of the wall. It leads to reduce thermal leakage and the electrical energy consumed to provide comfortable thermal conditions by 52.7%, in addition to decreasing the mass density by 14.1% while compressive strength decreased by 21%.


25 July 2024
Verified
Preprint
Open access
AHAtif Ali Hasan
Atif Ali Hasan
OZOmar Adil Zainal
Omar Adil Zainal
NLNoor Samir Lafta
Noor Samir Lafta
MKMahmood H. Khaleel
Mahmood H. Khaleel
This topic has been studied using constant interior and exterior finishing materials (Thermostone, 200 mm thick (A), fired clay bricks, 240 mm thick (B), hollow concrete blocks, 200 mm thick (C), solid concrete blocks, 140 mm thick (D), and limestone, 200 mm thick (E)) due to the availability of many different types of building materials in Iraq and the lack of control over the use of the best. to demonstrate how each of these materials affects a building’s insulation to deliver the appropriate levels of comfort and achieve the greatest possible reduction in the electrical energy needed for air conditioning. A unique chamber was created for performing the actual trials on such walls in their natural environment, which was the climate of the city of Baghdad (zip code 10016,33 ºN latitude, 44 ° E longitude). And a unique room was created for performing real-world tests on those walls, either in their current state of operation or with the addition of thermal insulation (60 mm thick microfiber glass insulation materials). The values for electricity consumption are 199,138,121,101,92 kW/m2 without the insulator, but when the insulator is used, the values become 54,92,63,100,58 kw/m2 for the models Case-C1, Case-E1, Case-B1, Case-D1, and Case-A1. respectively, the percentage of the reduction in electrical energy consumed by the room’s air conditioner ranges from 25–60%, depending on the model compared to the conventional model, and the difference in savings is only 35%. The amount of savings in the electrical energy consumed by the air-conditioning unit used (to provide standard thermal conditions inside the building) will decrease when the insulator is incorporated into the structural components because the savings difference will be equal to 15% only when changing the quality of the wall used (described in the study) compared to the traditional method.