Omar Adil Zainal

Dr. Omar Adil Zainal


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

15 November 2007 in International Journal of Food Engineering
Verified
Journal Article
Closed access
OZOmar Adil Zainal
Omar Adil Zainal
RKRavi Kumar
Ravi Kumar
GCGopal Chauhan
Gopal Chauhan
Food products of perishable nature are needed to be preserved from spoiling using the precooling technique. Precooling is the process of cooling fruits and vegetables as soon as possible after the harvest and prior to the transportation over long distances to a cold storage warehouse and marketing. Therefore, an experimental investigation has been carried out to study the temperature variation of different food products viz. apple, papaya and grape during the precooling process. Forced air cooling of food products was done by placing the particular food item inside a 4 m long rectangular air duct of 300 mm x 300 mm section. The temperature of cold air was in a range of 4-5 oC and the air velocity varied from 1.6 m/s to 4.1 m/s. The temperature of food product was measured at different radial locations inside the product. The effect of air velocity on the temperature profile of food product was observed and it has been found that the proper choice of cold air velocity can reduce the cooling time of certain food product up to 33 percent, thus, resulting in the saving of energy.


1 January 2024 in Journal of Thermal Engineering
Verified
Journal Article
Open access
PDF file
RARiyadh Husni Aljawad
Riyadh Husni Aljawad
AHAtif Ali Hasan
Atif Ali Hasan
MKMahmood H. Khaleel
Mahmood H. Khaleel
OZOmar Adil Zainal
Omar Adil Zainal
Due to the harsh climate in summer of the Iraq, the outer shell of buildings is exposed to heat flow from the outside ambient to the inside building space, and causes increase of heat gain in the space, so it requires the using of air conditioning units, which is led to consume electrical energy to remove that heat gain. The objective of this paper to reduce levels of electrical consumption by choosing best building materials. The best building materials which are those have good resistance against heat flow, that’s why the cost of building material difference each of other in the local market. While Aso Company for Bricks is considered one of the largest modern companies producing building materials and the most present in the entire area of Iraq. The aim of this study to focus was on its products, and five types models were selected and compared with the traditional model that is still used now. Therefore, heat gain test was experimentally conducted in a test room located in Baghdad city (zip code 10016, latitude of 33.2°N and longitude of 44°E) for one day from 6 a.m. to 7 p.m. and for the 21st day of each of the summer months (May to September) in 2021. The electrical energy consumed by the air-conditioning unit in the test room was measured, and the researchers concluded that the percentage of energy savings achieved within the limits (13.88–1.2%) depending on the type and thickness of the building material. Results shown the best building material is (Type IV), these blocks can be used to create walls with a thickness of 200 mm or 100 mm. Building blocks (the fourth kind), on the other hand, have a delay time of 6:30 hours and a thermal shrinkage coefficient of 0.63. They also have a density of 919 kg/m3. Therefore, the electrical consumption by A.C. units if used the blocks (Type IV) less than others.


27 October 2025 in Pollack Periodica
Verified
Journal Article
Closed access
PDF file
OZOmar Adil Zainal
Omar Adil Zainal
HOHadel Obaidi
Hadel Obaidi
MAMuhanad Al-jubouri
Muhanad Al-jubouri
ASAlaa Tariq Shukri
Alaa Tariq Shukri
Due to the transfer of environmental heat into buildings, requires consuming large amounts of electrical energy for absorbed heat gain. This study used sunflower seed husks as one of the industrial residues, as a waste material. These husks were ground into a nano-powder and blended with cement at a weight of 1:5. From this mixture made of 12 mm diameter balls then added back to the building block mix during formation. The thermal behavior of the walls constructed from these blocks was tested in the climate of Baghdad, during daylight hours on the 21st day of each summer month (May – July) in 2022. The optimal addition ratio was 4%, which achieved a heat load of 176.2 kW and an electricity consumption of 110.2 kWh, resulting energy savings of 18.1% compared with a traditional wall.