Interlaboratory comparisons are a basic part of the regular quality controls of laboratories to warranty the adequate performance of test and measurements. The exercise presented in this article is the comparison of indoor radon gas measurements under field conditions performed with passive detectors and active monitors carried out in the Laboratory of Natural Radiation (LNR). The aim is to provide a direct comparison between different methodologies and to identify physical reasons for possible inconsistencies, particularly related to sampling and measurement techniques. The variation of radon concentration during the comparison showed a big range of values, with levels from approximately 0.5 to 30 kBq/m3. The reference values for the two exposure periods have been derived from a weighted average of participants’ results applying an iterative algorithm. The indexes used to analyze the participants’ results were the relative percentage difference D(%), the Zeta score ( ζ ), and the z-score ( z ). Over 80% of the results for radon in air exposure are within the interval defined by the reference value and 20% and 10% for the first and the second exposure, respectively. Most deviations were detected with the overestimating of the exposure using passive detectors due to the related degassing time of detector holder materials.

Daniel RábagoDaniel Rábago
Daniel Rábago
LQLuis Santiago Quindos
Luis Santiago Quindos
AVArturo Vargas
Arturo Vargas
CSCarlos Sainz-Fernandez
Carlos Sainz-Fernandez
IRIleana Radulescu
Ileana Radulescu
Claudia GrossiClaudia Grossi
Claudia Grossi
Interlaboratory exercises are a good tool to compare the response of different systems to the same quantity and to identify possible inconsistencies between them. One of the main goals of the EMPIR 19ENV01 traceRadon project is to harmonize radon flux measurements based on different systems and methodologies. In the framework of the traceRadon Project, two radon flux intercomparison campaigns were carried out in October 2021 at high and at low radon source areas. Four institutions participated in the field intercomparison exercises with their own systems. Every system was based on a specific radon monitor (diffusion or pump mode) and an accumulation chamber (with manual or automatic opening). Radon fluxes were calculated by each participant using both exponential and linear fittings of the radon activity concentration measured over time within the accumulation chambers. The results of this study show mainly: (i) the exponential approach is not advisable due to the variability of the radon flux and the leakage of the systems during long-time measurements; (ii) the linear approach should be applied to minimize the measurement period in agreement with the time response and sensitivity of the monitors; (iii) radon flux measured at high radon source areas (radium content of about 800 Bq kg−1) risks being underestimated because of the influence of advective effects; (iv) radon flux measured at low radon source areas (radium content of about 30 Bq kg−1) may present large uncertainties if sensitive radon monitors with pump mode are not used.

1 September 2016 in Journal of Environmental Management
Verified
Journal Article
Closed access
FGFernando Gazquez
Fernando Gazquez
LQLuis Quindós-Poncela
Luis Quindós-Poncela
CSCarlos Sainz-Fernandez
Carlos Sainz-Fernandez
AFAlicia Fernández-Villar
Alicia Fernández-Villar
IFIsmael Fuente-Merino
Ismael Fuente-Merino
SGSantiago Celaya González
Santiago Celaya González

13 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Daniel RábagoDaniel Rábago
Daniel Rábago
EFEnrique Fernández
Enrique Fernández
SGSantiago Celaya González
Santiago Celaya González
IFIsmael Fuente-Merino
Ismael Fuente-Merino
AFAlicia Fernández
Alicia Fernández
CSCarlos Sainz-Fernandez
Carlos Sainz-Fernandez
A comparison of low-cost radon monitors was conducted at the Laboratory of Natural Radiation (LNR). The monitors we evaluated were EcoQube, RadonEye, RadonEye Plus2, Spirit, ViewPlus, ViewRadon and WavePlus. An AlphaGUARD monitor calibrated at the Laboratory of Environmental Radioactivity of the University of Cantabria (LaRUC), accredited for testing and calibration according to ISO/IEC 17025, provided the reference value of radon concentration. The temporal stability of the monitors was studied, obtaining a percentage of missing records ranged from 1% to 19% of the data. The main technical characteristics studied were temporal stability, measurement ranges, accuracy, correlation and response time. The main results show that the measurement ranges align with those specified by their manufacturers, with percentage differences with respect to the reference monitor of between 5% and 16%. The diversity found for response time is remarkable, with values ranging from 1 to 15 h, with Pearson correlation factors between 0.63 and 0.90.

AFAlicia Fernández
Alicia Fernández
CSCarlos Sainz-Fernandez
Carlos Sainz-Fernandez
SGSantiago Celaya González
Santiago Celaya González
LQLuis Quindós
Luis Quindós
Daniel RábagoDaniel Rábago
Daniel Rábago
IFIsmael Fuente-Merino
Ismael Fuente-Merino
One of the requirements of EU-BSS (European Basic Safety Standards) is the design and implementation of a National Radon Action Plan in the member states. This should define, as accurately as possible, areas of risk for the presence of radon gas (222Rn) in homes and workplaces. The concept used by the Spanish Nuclear Safety Council (CSN), the body responsible for nuclear safety and radiation protection in Spain, to identify “radon priority areas” is that of radon potential. This paper establishes a different methodology from that used by the CSN, using the same study variables (indoor radon measurements, gamma radiation exposure data, and geological information) to prepare a radon potential map that improves the definition of the areas potentially exposed to radon in Spain. The main advantage of this methodology is that by using simple data processing the definition of these areas is improved. In addition, the application of this methodology can improve the delimitation of radon priority areas and can be applied within the cartographic system used by the European Commission-Joint Research Center (EC-JRC) in the representation of different environmental parameters.

CSCarlos Sainz-Fernandez
Carlos Sainz-Fernandez
JFJulia Fábrega
Julia Fábrega
Daniel RábagoDaniel Rábago
Daniel Rábago
SGSantiago Celaya González
Santiago Celaya González
AFAlicia Fernandez
Alicia Fernandez
LQLuis Quindos
Luis Quindos
A study is presented on rapid episodes of air exchange in the Polychrome Room of the Altamira Cave (Cantabria, Spain) using continuous monitoring of radon and CO2 tracer gases, as well as environmental parameters such as internal and external air temperature. For this, criteria have been developed to carry out an inventory of these types of events during the 2015–2020 period. Most of the degassing-recharging events occur over several hours or days, especially during spring and autumn. This means that the room can be significantly ventilated during these short periods of time, posing an exchange of energy and matter with potential impact in the preservation of the rock art present inside. In addition, the hypothesis that temperature gradients between the internal and external atmosphere is one of the main factors that induces degassing has been tested. To this end, correlation analysis has been carried out between the different magnitudes involved in this study, such as radon and CO2 concentrations, and air temperature gradients. A total of 37 degassing-recharging events have been analyzed for the 5 year studied period. The distribution of the duration of the events have been described, as well as that of the correlations between the degassing and recharge stages of each event, showing significant values of r coefficients for the correlation with temperature gradients between the internal and external atmosphere.