Silvia Schievano

Prof. Silvia Schievano


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2007 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Closed access
SSSilvia Schievano
Silvia Schievano
LCLouise Coats
Louise Coats
FMFrancesco Migliavacca
Francesco Migliavacca
WNWendy Norman
Wendy Norman
AFAlessandra Frigiola
Alessandra Frigiola
ATAndrew M. Taylor
Andrew M. Taylor
Our aim was to identify sub-groups of right ventricular outflow tract morphology that would be suitable for percutaneous pulmonary valve implantation and to document their prevalence in our patient population. Eighty-three consecutive patients with right ventricular outflow tract dysfunction (5-41 years, 76% tetralogy of Fallot) referred to our center for cardiovascular magnetic resonance were studied. A morphological classification was created according to visual assessment of three-dimensional reconstructions and detailed measurement. Diagnosis, right ventricular outflow tract type, surgical history and treatment outcomes were documented. Right ventricular outflow tract morphology was heterogeneous; nevertheless, 5 patterns were visually identified. Type I, a pyramidal morphology, was most prevalent (49%) and related to the presence of a transannular patch. Other types (II-V) were seen more commonly in patients with conduits. Two patients had unclassifiable morphology. Ninety-five percent of patients were assigned to the correct morphological classification by visual assessment alone. Percutaneous pulmonary valve implantation was performed successfully in 10 patients with Type II-V morphology and in 1 patient with unclassifiable morphology. Percutaneous implantation was not performed in patients with Type I morphology. Only right ventricular outflow tract diameters < 22 mm in diameter were suitable for the current device. We have created a morphological classification of the RVOT in patients referred for assessment of RVOT dysfunction. Though only 13% of our patients underwent percutaneous implantation, > 50% of outflow tract morphologies may be suitable for this approach, in particular with the development of new devices appropriate for larger outflow.

1 January 2013 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
GBGiovanni Biglino
Giovanni Biglino
PVPeter Verschueren
Peter Verschueren
RZRaf Zegels
Raf Zegels
ATAndrew M Taylor
Andrew M Taylor
SSSilvia Schievano
Silvia Schievano
Compliant vascular phantoms are desirable for in-vitro patient-specific experiments and device testing. TangoPlus FullCure 930® is a commercially available rubber-like material that can be used for PolyJet rapid prototyping. This work aims to gather preliminary data on the distensibility of this material, in order to assess the feasibility of its use in the context of experimental cardiovascular modelling.

17 March 2004 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Closed access
PDF file
FMFrancesco Migliavacca
Francesco Migliavacca
Lorenza PetriniLorenza Petrini
Lorenza Petrini
PMPaolo Massarotti
Paolo Massarotti
SSSilvia Schievano
Silvia Schievano
FAFerdinando Auricchio
Ferdinando Auricchio
GDGabriele Dubini
Gabriele Dubini

19 September 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PKPaul G. M. Knoops
Paul G. M. Knoops
APAthanasios Papaioannou
Athanasios Papaioannou
ABAlessandro Borghi
Alessandro Borghi
RBRichard W. F. Breakey
Richard W. F. Breakey
AWAlexander T. Wilson
Alexander T. Wilson
SSSilvia Schievano
Silvia Schievano
Current computational tools for planning and simulation in plastic and reconstructive surgery lack sufficient precision and are time-consuming, thus resulting in limited adoption. Although computer-assisted surgical planning systems help to improve clinical outcomes, shorten operation time and reduce cost, they are often too complex and require extensive manual input, which ultimately limits their use in doctor-patient communication and clinical decision making. Here, we present the first large-scale clinical 3D morphable model, a machine-learning-based framework involving supervised learning for diagnostics, risk stratification, and treatment simulation. The model, trained and validated with 4,261 faces of healthy volunteers and orthognathic (jaw) surgery patients, diagnoses patients with 95.5% sensitivity and 95.2% specificity, and simulates surgical outcomes with a mean accuracy of 1.1 ± 0.3 mm. We demonstrate how this model could fully-automatically aid diagnosis and provide patient-specific treatment plans from a 3D scan alone, to help efficient clinical decision making and improve clinical understanding of face shape as a marker for primary and secondary surgery.

1 January 2008 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
FGFrank Jh Gijsen
Frank Jh Gijsen
FMFrancesco Migliavacca
Francesco Migliavacca
SSSilvia Schievano
Silvia Schievano
LSLaura Socci
Laura Socci
Lorenza PetriniLorenza Petrini
Lorenza Petrini
GDGabriele Dubini
Gabriele Dubini
The process of restenosis after a stenting procedure is related to local biomechanical environment. Arterial wall stresses caused by the interaction of the stent with the vascular wall and possibly stress induced stent strut fracture are two important parameters. The knowledge of these parameters after stent deployment in a patient derived 3D reconstruction of a diseased coronary artery might give insights in the understanding of the process of restenosis. 3D reconstruction of a mildly stenosed coronary artery was carried out based on a combination of biplane angiography and intravascular ultrasound. Finite element method computations were performed to simulate the deployment of a stent inside the reconstructed coronary artery model at inflation pressure of 1.0 MPa. Strut thickness of the stent was varied to investigate stresses in the stent and the vessel wall. Deformed configurations, pressure-lumen area relationship and stress distribution in the arterial wall and stent struts were studied. The simulations show how the stent pushes the arterial wall towards the outside allowing the expansion of the occluded artery. Higher stresses in the arterial wall are present behind the stent struts and in regions where the arterial wall was thin. Values of 200 MPa for the peak stresses in the stent strut were detected near the connecting parts between the stent struts, and they were only just below the fatigue stress. Decreasing strut thickness might reduce arterial damage without increasing stresses in the struts significantly. The method presented in this paper can be used to predict stresses in the stent struts and the vessel wall, and thus evaluate whether a specific stent design is optimal for a specific patient.

14 June 2018 in British Journal of Radiology
Verified
Journal Article
Closed access
SSSusan C Shelmerdine
Susan C Shelmerdine
ISIan C Simcock
Ian C Simcock
JHJohn Ciaran Hutchinson
John Ciaran Hutchinson
RARosalind Aughwane
Rosalind Aughwane
AMAndrew Melbourne
Andrew Melbourne
OAOwen J Arthurs
Owen J Arthurs
Microfocus computed tomography (micro-CT) is an imaging method that provides three dimensional (3D) digital datasets with comparable resolution to light microscopy. Although it has traditionally been used for non-destructive testing in engineering, aerospace industries and in preclinical animal studies, new applications are rapidly becoming available in the clinical setting including post-mortem fetal imaging and pathological specimen analysis. Printing three dimensional models from imaging datasets for educational purposes is well established in the medical literature, but typically using low resolution (0.7 mm voxel size) data acquired from computed tomography (CT) or magnetic resonance (MR) examinations. With higher resolution imaging (voxel sizes below 1 micron, <0.001mm) at micro-CT, smaller structures can be better characterised, and datasets post-processed to create accurate anatomical models for review and handling. In this review, we provide examples of how 3D printing of micro-CT imaged specimen...