The thermal bias drift problem induces poor stability of the operating point of integrated optical electric field sensor and thus large measurement errors in the practical applications. In this paper, we have proposed a passive thermal compensation approach to an inherently temperature insensitive integrated electric field sensor. Both theoretical analysis and experiments demonstrated that the thermal bias drift can be effectively suppressed by combination design of waveguide width and length of the asymmetric Mach-Zehnder interferometer. Based on this new waveguide design, a temperature compensated electric field sensor with optimal geometrical parameters was fabricated. Its thermal bias drift was reduced from -3.3°/°C to 0.23°/°C, more than ten times lower than the uncompensated conventional sensor. Furthermore, the maximum/minimum detectable electric fields are 2.5kV/m and 200 kV/m respectively for measuring lighting impulse electric field and the measurement error as low as 1.6% was achieved from 18°C to 28°C. These results are very encouraging toward implementing practical integrated optical electric field sensing schemes.
In this paper, an asymmetric Mach-Zehnder interferometer with straight waveguide arms based integrated optical electric field sensor is proposed. Compared with the present reported integrated optical electric field sensors, the proposed sensor has relatively lower transmission loss, higher extinction ratio, much larger linear measurable range, and better thermal stability. The transmission loss of the device is demonstrated to be as low as 6 dB and the extinction ratio is as high as 35 dB. Moreover, the sensor has a linear measurable range of approximately 34 dB and the minimal detectable electric field strength of 10 V/m is achieved in the experiments. Combining the wavelength tuning technique, the thermal variations in the sensor bias have fallen from around 120 degrees down to be 2 degrees with the temperature ranging from 24°C to 70°C. These results are very encouraging toward the development of integrated optical electric field sensing systems in the practical applications.
18 January 2019 in Instrumentation Science & Technology
The performance of a magnetic fluid clad microfiber knot–based magnetic field sensor was experimentally investigated in the presence of static and dynamic magnetic fields. In addition, the dependence of the sensor response on the orientation of the externally applied magnetic field has been evaluated. The results show that the proposed sensor provides simultaneous measurements of magnetic field strength and orientation by monitoring the resonant wavelength of microfiber knot. When the magnetic field was increased to 220 Gs, the maximum wavelength shift reached nearly 130 pm. To avoid rectification for alternating current magnetic field input, a direct current magnetic field bias was introduced to the sensor. Using this approach, the unipolar response was converted into a bipolar form, which produced an acceptable replica of the input sinusoidal waveform. These results provide great promise for the development of practical magnetic fluid-based fiber-photonic magnetic field devices.
6 July 2023 in Instrumentation Science & Technology
We investigated the sensing performance of a tapered microfiber, which was in evanescent contact with a multimode slab waveguide. The effects of the sensor configuration parameters on its transmission features and sensitivity were found for both the resonant-wavelength-shift scheme and light-intensity-variation scheme through theoretical and numerical calculations. On the basis of these results, we propose rules for optimizing geometrical parameters of the slab coupled microfiber sensors. With this approach, the slope of resonant spectra and resonant wavelength shift were increased. As a result, the sensitivity was substantially improved. It was shown that the potential device sensitivity can be as high as approximately 20,000 nm/RIU by matching optimal geometrical parameters. These results may provide beneficial references in optimally designing and fabricating slab coupled microfiber sensors to satisfy the requirements in applications.
In recent years, modulated grating Y-branch lasers have been widely used in optical communication, sensing, and spectral analysis. However, the relationship between this laser’s output wavelength and control current is complex, and the manual traversal screening method is time-consuming and inefficient. This paper proposes a fast wavelength-current lookup table generation method based on coarse and fine current tuning. The final total scanning current combination data of this method is only about 40000 sets. Compared with the ergodic screening method, the data volume is significantly reduced, the scanning time is reduced, and the efficiency is improved. Theoretical and experimental test results show that the output tuning range of the designed MG-Y laser is up to 40 nm, the wavelength interval is only 0.008 nm, and the wavelength stability is better than 0.002 nm.