Joanna Sliwka

Joanna Sliwka

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2020 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
TBTheo M M H de By
Theo M M H de By
CAChristiaan F J Antonides
Christiaan F J Antonides
MSMartin Schweiger
Martin Schweiger
JSJoanna Sliwka
Joanna Sliwka
BDBen Davies
Ben Davies
OMOliver Miera
Oliver Miera
OBJECTIVES: A second paediatric report has been generated from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). The purpose of EUROMACS, which is operated by the European Association for Cardio-Thoracic Surgery, is to gather data related to durable mechanical circulatory support for scientific purposes and to publish reports with respect to the course of mechanical circulatory support therapy. Since the first report issued, efforts to increase compliance and participation have been extended. Additionally, the data provided the opportunity to analyse patients of younger age and lower weight. METHODS: Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (≤19 years of age) performed from 1 January 2000 to 1 July 2019 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events including neurological dysfunction, device malfunction, major infection and bleeding. RESULTS: Twenty-nine hospitals contributed 398 registered implants in 353 patients (150 female, 203 male) to the registry. The most frequent aetiology of heart failure was any form of cardiomyopathy (61%), followed by congenital heart disease and myocarditis (16.4% and 16.1%, respectively). Competing outcomes analysis revealed that a total of 80% survived to transplant or recovery or are ongoing; at the 2-year follow-up examination, 20% died while on support. At 12 months, 46.7% received transplants, 8.7% were weaned from their device and 18.5% died. The 3-month adverse events rate was 1.69 per patient-year for device malfunction including pump exchange, 0.48 for major bleeding, 0.64 for major infection and 0.78 for neurological events. CONCLUSIONS: The overall survival rate was 81.5% at 12 months following ventricular assist device implant. The comparison of survival rates of the early and later eras shows no significant difference. A focus on specific subgroups showed that survival was less in patients of younger age (<1 year of age) (P = 0.01) and lower weight (<20 kg) (P = 0.015). Transplant rates at 6 months continue to be low (33.2%) The fact that the EUROMACS registry is embedded within the European Association for Cardio-Thoracic Surgery Quality Improvement Programme offers opportunities to focus on improving outcomes.

8 November 2022 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Open access
PDF file
SRSofie Rohde
Sofie Rohde
ESEugen Sandica
Eugen Sandica
KVKevin Veen
Kevin Veen
UKUlrike S Kraemer
Ulrike S Kraemer
TTTimothy Thiruchelvam
Timothy Thiruchelvam
TBTheo M M H de By
Theo M M H de By
The Berlin Heart EXCOR (BHE) offers circulatory support across all paediatric ages. Clinically, the necessary care and the outcomes differ in various age groups. The EUROMACS database was used to study age- and size-related outcomes for this specific device. All patients <19 years of age from the EUROMACS database supported with a BHE between 2000 and November 2021 were included. Maximally selected rank statistics were used to determine body surface area (BSA) cut-off values. Multivariable Cox proportional hazard regression using ridge penalization was performed to identify factors associated with outcomes. In total, 303 patients were included [mean age: 2.0 years (interquartile range: 0.6–8.0, males: 48.5%)]. Age and BSA were not significantly associated with mortality (n = 74, P = 0.684, P = 0.679). Factors associated with a transplant (n = 175) were age (hazard ratio 1.07, P = 0.006) and aetiology other than congenital heart disease (hazard ratio 1.46, P = 0.020). Recovery rates (n = 42) were highest in patients with a BSA of <0.53 m2 (21.8% vs 4.3–7.6% at 1 year, P = 0.00534). Patients with a BSA of ≥0.73 m2 had a lower risk of early pump thrombosis but a higher risk of early bleeding compared to children with a BSA of <0.73 m2. Mortality rates in Berlin Heart-supported patients cannot be predicted by age or BSA. Recovery rates are remarkably high in the smallest patient category (BSA <0.53 m2). This underscores that the BHE is a viable therapeutic option, even for the smallest and youngest patients.

27 June 2022 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
PDF file
TBTheo M M H de By
Theo M M H de By
Martin SchweigerMartin Schweiger
Martin Schweiger
HHHina Hussain
Hina Hussain
AAAntonio Amodeo
Antonio Amodeo
TMThomas Martens
Thomas Martens
OMOliver Miera
Oliver Miera
A third paediatric report has been generated from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). The purpose of EUROMACS, which is operated by the European Association for Cardio-Thoracic Surgery, is to gather data related to durable mechanical circulatory support for scientific purposes and to publish reports with respect to the course of mechanical circulatory support therapy. Since the first report issued, efforts to increase compliance and participation have been extended. Additionally, the data provided the opportunity to analyse patients of younger age and lower weight. Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (<19 years of age) performed from 1 January 2000 to 31 December 2020 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events including neurological dysfunction, device malfunction, major infection and bleeding. Twenty-five hospitals contributed 537 registered implants in 480 patients. The most frequent aetiology of heart failure was any form of cardiomyopathy (59%), followed by congenital heart disease and myocarditis (15% and 14%, respectively). Competing outcomes analysis revealed that a total of 86% survived to transplant or recovery or are ongoing; at the 2-year follow-up examination, 21.9% died while on support. At 12 months, 45.1% received transplants, 7.5% were weaned from their device and 20.8% died. The 3-month adverse events rate was 1.59 per patient-year for device malfunction including pump exchange, 0.7 for major bleeding, 0.78 for major infection and 0.71 for neurological events. The overall survival rate was 79.2% at 12 months following ventricular assist device implant. The comparison of survival rates of the early and later eras shows no significant difference. A focus on specific subgroups showed that survival was less in patients of younger age (<1 year of age; P = 0.01) and lower weight (<20 kg; P = 0.015). Transplant rates at 6 months continue to be low (33.2%).

Verified
Journal Article
Open access
PDF file
Martin SchweigerMartin Schweiger
Martin Schweiger
HHHina Hussein
Hina Hussein
TBTheo M. M. H. de By
Theo M. M. H. de By
Daniel ZimpferDaniel Zimpfer
Daniel Zimpfer
JSJoanna Sliwka
Joanna Sliwka
BMBart Meyns
Bart Meyns
Purpose: The withdrawal of HVAD in 2021 created a concern for the pediatric population. The alternative implantable centrifugal blood pump HeartMate 3 has since been used more frequently in children. This paper analyses the outcome of children on LVAD support provided with an HVAD or HM3. Methods: A retrospective analysis of the EUROMACS database on children supported with VAD < 19 years of age from 1 January 2009 to 1 December 2021 was conducted. All patients with an LVAD and either an HVAD or HM3 were included. Patients with missing data on VAD status and/or missing baseline and/or follow up information were excluded. Kaplan–Meier survival analysis was performed to evaluate survival differences. Analyses were performed using Fisher’s exact test. Results: The study included 150 implantations in 142 patients with 128 implants using an HVAD compared to 28 implants using an HM3. Nine patients (6%) needed temporary right ventricular mechanical support, which was significantly higher in the HM3 group, with 25% (p: 0.01). Patients in the HVAD group were significantly younger (12.7 vs. 14.5 years, p: 0.01), weighed less (45.7 vs. 60 kg, p: <0.000) and had lower BSA values (1.3 vs. 1.6 m2, p: <0.000). Median support time was 204 days. Overall, 98 patients (69%) were discharged and sent home, while 87% were discharged in group HM3 (p: ns). A total of 123 children (86%) survived to transplantation, recovery or are ongoing, without differences between groups. In the HVAD group, 10 patients (8%) died while on support, whereas in 12% of HM3 patients died (p: 0.7). Conclusions: Survival in children implanted with an HM3 was excellent. Almost 90% were discharged and sent home on the device.

1 January 2020 in Polish Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Open access
JSJoanna Sliwka
Joanna Sliwka
MTMirosław Tyrpień
Mirosław Tyrpień
PWPiotr M. Wilczek
Piotr M. Wilczek
MZMarian Zembala
Marian Zembala
PPPiotr Przybyłowski
Piotr Przybyłowski
The qualification of new knowledge is one of the oldest problems in experimental medicine that provides a link between fundamental discovery, hypothesis, ‘proof of concept’ preclinical studies and development of clinical trials. The biggest challenge in animal models is the proper evaluation...

18 June 2024 in ACS Omega
Verified
Journal Article
Open access
MKMarcin Zbigniew Krasoń
Marcin Zbigniew Krasoń
APAnna Paradowska
Anna Paradowska
SBSlawomir Boncel
Slawomir Boncel
MLMateusz Lejawa
Mateusz Lejawa
MFMartyna Fronczek
Martyna Fronczek
MRMarek W. Radomski
Marek W. Radomski
Interactions of graphene oxide (GO) with an ex vivo rat heart and its coronary vessels have not been studied yet. Moreover, the conflicting data on the "structure-properties" relationships do not allow for biomedical applications of GO. Herein, we study the impact of GO on the ex vivo isolated rat heart, normotensive and hypertensive, under the working heart and the constant-pressure perfusion (Langendorff) regimes. Four structural GO variants of the following initial morphology were used: few-layer (below 10-layer) GO1, O < 49%; predominantly single-layer GO2, O = 41-50%; 15-20-layer GO3, O < 11%; and few-layer (below 10-layer) NH4+-functionalized GO4, O < 44%, N = 3-6%. The aqueous GO dispersions, sonicated and stabilized with bovine serum albumin in Krebs-Henseleit-like solution & horbar;uniformized in terms of the particle size & horbar;were eventually size-monodisperse as revealed by dynamic light scattering. To study the cardiotoxicity mechanisms of GO, histopathology, Raman spectroscopy, analysis of cardiac parameters (coronary and aortic flows, heart rate, aortic pressure), and nitric oxide (NO-)-dependent coronary flow response to bradykinin (blood-vessel-vasodilator) were used. GO1 (10 mg/L) exerted no effects on cardiac function and preserved an increase in coronary flow in response to bradykinin. GO2 (10 mg/L) reduced coronary flow, aortic pressure in normotensive hearts, and coronary flow in hypertensive hearts, and intensified the response to bradykinin in normal hearts. GO3 (10 mg/L) reduced all parameters in hypertensive hearts and coronary response to bradykinin in normal hearts. At higher concentrations (normotensive hearts, 30 mg/L), the coronary response to bradykinin was blocked. GO4 (10 mg/L) reduced the coronary flow in normal hearts, while for hypertensive hearts, all parameters, except the coronary flow, were reduced and the coronary response to bradykinin was blocked. The results showed that a low number of GO layers and high O-content were safer for normal and hypertensive rat hearts. Hypertensive hearts deteriorated easier upon perfusion with low-O-content GOs. Our findings support the necessity of strict control over the GO structure during organ perfusion and indicate the urgent need for personalized medicine in biomedical applications of GO.