Daniel Zimpfer

Dr. Daniel Zimpfer

1. Division of Cardiac Surgery, Medical University of Vienna, 1090 Vienna, Austria
+1
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2007 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
Daniel ZimpferDaniel Zimpfer
Daniel Zimpfer
PZPhilipp Zrunek
Philipp Zrunek
WRWilfried Roethy
Wilfried Roethy
Martin CzernyMartin Czerny
Martin Czerny
HSHeinz Schima
Heinz Schima
GWGeorg Wieselthaler
Georg Wieselthaler

4 April 2017 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
TKThomas Krabatsch
Thomas Krabatsch
INIvan Netuka
Ivan Netuka
JSJan D. Schmitto
Jan D. Schmitto
Daniel ZimpferDaniel Zimpfer
Daniel Zimpfer
JGJens Garbade
Jens Garbade
YPYuriy Pya
Yuriy Pya
The HeartMate 3 Left Ventricular Assist System (LVAS) (St. Jude Medical Inc., St Paul, MN) with full magnetic levitation allows for wide and consistent blood flow paths and an artificial pulse designed for enhanced hemocompatibility. The HeartMate 3 received market approval in the European Union in 2015 following completion of a multicenter study. After reaching the 6-month study endpoint, patients continue to be followed for 2 years with the 1-year results presented herein. A prospective, non-randomized study included adults with advanced heart failure and ejection fraction (EF) ≤ 25%, cardiac index (CI) ≤ 2.2 L/min/m2 while not on inotropes, or inotrope dependent, or on optimal medical management for 45/60 days. Fifty patients—54% bridge to transplant (BTT) and 46% destination therapy (DT)—were enrolled and implanted with the HeartMate 3. At baseline, 92% of the patients were INTERMACS profiles 2–4, with cardiac index 1.8 + 0.5 L/min/m2 and 58% were supported with inotropes. At 1 year, 74% of the patients remain on support, 18% expired, 6% transplanted, and 2% explanted. The adverse events include 12% gastrointestinal bleeding, 16% driveline infections, 18% strokes, and 2% outflow graft thrombosis. There was no hemolysis, pump thrombosis or pump malfunction through 1 year. The six-minute walk test distance increased from a mean of 273 m to 371 m (P <0.0001). EQ-5D quality-of-life score increased from a mean of 52.7 to 70.8 (P = 0.0006). The 1-year HeartMate 3 LVAS results show survival and adverse-event profile are similar to other approved devices, with no pump thrombosis or pump failure. Patient’s functional status and quality of life significantly improved over time. Clinicaltrials.gov registration number: NCT02170363 . Registered June 19, 2014.

30 November 2023 in European Heart Journal
Verified
Journal Article
Open access
PDF file
JSJan D. Schmitto
Jan D. Schmitto
SSSteven Shaw
Steven Shaw
JGJens Garbade
Jens Garbade
FGFinn Gustafsson
Finn Gustafsson
MMMichiel Morshuis
Michiel Morshuis
DSDiyar Saeed
Diyar Saeed
Background and Aims: HeartMate 3 (HM3) is a fully magnetically levitated continuous flow left ventricular assist device, which received CE marking in 2015. The ELEVATE Registry was initiated to collect real-world outcomes in patients treated with HM3 post-CE Mark approval. Methods: A total of 540 subjects implanted at 26 centres between March 2015 and February 2017 were included in this registry. Of these, 463 received the device as a primary implant (primary implant cohort, PIC), 19 as a pump exchange (pump exchange cohort), and in 58 patients, only anonymized survival data were collected (anonymized cohort, AC). Patients in the PIC contributed to the baseline demographics, survival, adverse events, quality of life (QoL) (EuroQoL-5 Dimensions-5 Levels visual analogue scale), and functional capacity (6 min walk distance) assessments, while patients in the AC contributed only to survival. Results: Primary implant cohort patients had a mean age of 56 years and were predominantly male (89%) with 48% ischaemic aetiology. The majority of subjects was designated bridge to transplant (66%) and had INTERMACS Profiles 1–3 (70%). At baseline, the subjects had poor functional capacity (104 ± 140 m) and impaired QoL (35 ± 19 points). The overall survival rate of the PIC was 63.3% and survival free of stroke was 58.1% at 5 years. Significant improvements in functional capacity and QoL were observed and maintained for 5 years (301 ± 131 m and 64 ± 20 points, respectively). Conclusions: Real-world data from the ELEVATE registry demonstrate an overall survival rate for primary implants of 63.3%. In the PIC, reductions in adverse events for patients in the extended follow-up and improved QoL and functional capacity were observed at 5 years in this patient population with advanced heart failure.

1 March 2006 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
Daniel ZimpferDaniel Zimpfer
Daniel Zimpfer
BHBirgit Heinisch
Birgit Heinisch
Martin CzernyMartin Czerny
Martin Czerny
THThomas Hoelzenbein
Thomas Hoelzenbein
STSharok Taghavi
Sharok Taghavi
MGMichael Grimm
Michael Grimm

1 April 2007 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
Daniel ZimpferDaniel Zimpfer
Daniel Zimpfer
PZPhilipp Zrunek
Philipp Zrunek
SSSigrid Sandner
Sigrid Sandner
HSHeinz Schima
Heinz Schima
MGMichael Grimm
Michael Grimm
GWGeorg Wieselthaler
Georg Wieselthaler
We have previously shown that fixed pulmonary hypertension in cardiac transplant candidates can be lowered using left ventricular assist devices (LVADs). The post-transplant survival of these patients is uncertain as pulmonary hypertension may reappear, possibly affecting post-transplant survival. Between 01/2000 and 01/2005 a total of 26 cardiac transplant candidates (92% male; mean age 56.2 years) in whom fixed pulmonary hypertension was lowered by LVAD implantation (pulmonary vascular resistance (PVR) before implantation: 5.1+/-2.8wood units (WU); PVR before cardiac transplantation: 2.0+/-.9WU) underwent cardiac transplantation at our institution. These patients were age and sex matched with 52 cardiac transplant candidates without pulmonary hypertension undergoing cardiac transplantation during the same time period. Study endpoints were peri-transplant complications and long-term survival. Mean follow-up was 36+/-14 months. Peri-transplant mortality was 5% in patients after LVAD therapy and 7% in patients without prior LVAD therapy (p=.089). We observed 2 cases (4%) of acute right heart failure requiring mechanical support in patients without prior LVAD therapy. None of the patients with LVAD therapy developed peri-transplant right heart failure requiring mechanical support. Incidence of other peri-transplant complications was comparable between the two groups. Log-rank (p=.124) revealed comparable long-term survival between patients with (1 year: 85%, 2 year: 85%, 3 year: 85%) and without (1 year: 90%, 2 year 82%, 3 year prior 79%) prior LVAD therapy. LVAD therapy lowers fixed pulmonary hypertension in cardiac transplant candidates with fixed pulmonary hypertension. Thereafter, long-term post-transplant survival is comparable to cardiac transplant recipients without pulmonary hypertension.

14 October 2020 in European Heart Journal
Verified
Journal Article
Closed access
Daniel ZimpferDaniel Zimpfer
Daniel Zimpfer
FGFinn Gustafsson
Finn Gustafsson
EPEvgenij Potapov
Evgenij Potapov
YPYuriy Pya
Yuriy Pya
JSJan Schmitto
Jan Schmitto
JGJens Garbade
Jens Garbade
Aims: The ELEVATE Registry was designed to study long-term outcomes with the Heartmate 3 (HM3), a fully magnetically levitated centrifugal ventricular assist device, in a real-world population following CE-mark approval. Methods and results: A total of 540 patients, implanted in Europe and the Middle East were followed in ELEVATE. The registry included 463 patients receiving the HM3 as primary implant (Primary Implant Cohort), 19 patients underwent a pump upgrade from another device (Pump Exchange Cohort) and 58 patients who had experienced an outcome before having the possibility to sign the Informed Consent, for which only outcome data were collected (Anonymized Cohort). Data collection included demographics, survival, adverse events, EQ-5D Visual Analog Score quality of life (EQ-5D VAS QOL) questionnaire, and 6-min walk distance (6MWD). Mean age was 55.6 ± 11.7 years (89% male, 48% ischaemic cardiomyopathy). Seventy per cent of patients were in INTERMACS Profile 1–3 and 12.7% were on temporary mechanical circulatory support. Primary Implant Cohort survival was 83% after 2 years. In the Powered by Editorial Manager® and ProduXion Manager® from Aries Systems Corporation Primary Implant Cohort, strokes were observed in 10.2%, gastrointestinal bleedings in 9.7%, pump thrombosis in 1.5%, and outflow graft twists in 3.5%. Heartmate 3 implantation resulted in a significant and sustained improvement of functional capacity and QOL. Conclusion: In a real-world population, cohort implanted with the HM3 left ventricular assist device we demonstrate good long-term survival, sustained improvement of functional capacity, and low rates of adverse events (including pump thrombosis). ClinicalTrials.gov Identifier: NCT02497950