Romain Vayron

Dr. Romain Vayron

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2020 in Medical Engineering & Physics
Verified
Journal Article
Closed access
MFManon Fraulob
Manon Fraulob
SPSiyuan Pang
Siyuan Pang
SCSophie Le Cann
Sophie Le Cann
RVRomain Vayron
Romain Vayron
MLMathilde Laurent-Brocq
Mathilde Laurent-Brocq
GHGuillaume Haiat
Guillaume Haiat
Titanium implants are widely used in dental and orthopedic surgeries. Osseointegration phenomena lead to direct contact between bone tissue and the implant surface. The quality of the bone-implant interface (BII), resulting from the properties of newly formed bone, determines the implant stability. This study investigates the BII properties using a dedicated in vivo implant model consisting of a coin-shaped Ti-6Al-4V implant inserted in a rabbit femur for 10 weeks. A gap created below the implant was filled with newly formed bone tissue after healing. The properties of mature and newly formed bone tissues were compared using: i) Raman spectroscopy to assess the nanoscale compositional bone properties and ii) nanoindentation to quantify microscale elastic properties in site-matched regions. The mineral-to-matrix ratio, crystallinity (mineral size and lattice order), and the collagen cross-link ratio were significantly lower in newly formed bone tissue (e.g., a mineral-to-matrix ratio of 9.3 ± 0.5 for proline 853 cm-1) compared to mature bone (15.6 ± 1). Nanoindentation measurements gave Young's modulus of 12.8 ± 1.8 GPa for newly formed bone and 15.7 ± 2.3 GPa for mature bone. This multimodal and multiscale approach leads to a better understanding of osseointegration phenomena.

28 October 2020 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
MFManon Fraulob
Manon Fraulob
SCSophie Le Cann
Sophie Le Cann
BVBenjamin Voumard
Benjamin Voumard
HYHirokazu Yasui
Hirokazu Yasui
KYKeita Yano
Keita Yano
GHGuillaume Haiat
Guillaume Haiat
Titanium implants are widely used in dental and orthopedic surgeries. However, implant failures still occur because of a lack of implant stability. The biomechanical properties of bone tissue located around the implant need to be assessed to better understand the osseointegration phenomena and anticipate implant failure. The aim of this study was to explore the spatiotemporal variation of the microscopic elastic properties of newly formed bone tissue close to an implant. Eight coin-shaped Ti6Al4V implants were inserted into rabbit tibiae for 7 and 13 weeks using an in vivo model allowing the distinction between mature and newly formed bone in a standardized configuration. Nanoindentation and micro-Brillouin scattering measurements were carried out in similar locations to measure the indentation modulus and the wave velocity, from which relative variations of bone mass density were extracted. The indentation modulus, the wave velocity and mass density were found to be higher (1) in newly formed bone tissue located close to the implant surface, compared to mature cortical bone tissue, and (2) after longer healing time, consistently with an increased mineralization. Within the bone chamber, the spatial distribution of elastic properties was more heterogeneous for shorter healing durations. After 7 weeks of healing, bone tissue in the bone chamber close to the implant surface was 12.3% denser than bone tissue further away. Bone tissue close to the chamber edge was 16.8% denser than in its center. These results suggest a bone spreading pathway along tissue maturation, which is confirmed by histology and consistent with contact osteogenesis phenomena.

2 November 2023 in Coatings
Verified
Journal Article
Open access
PDF file
AWAnna Wozniak
Anna Wozniak
VHVincent Humblot
Vincent Humblot
RVRomain Vayron
Romain Vayron
RDRémi Delille
Rémi Delille
CFCéline Falentin-Daudré
Céline Falentin-Daudré
Poly(dimethyl siloxane) (PDMS) is one of the most widely used materials in the biomedical field. Despite its numerous advantages, its hydrophobic character promotes bacterial adhesion and biofilm formation. For breast implants, biocompatibility is challenged due to the biofilm formed around the implant that can degenerate to severe capsular contracture over time. Thus, the laboratory has set up strategies to prevent bacterial contamination by grafting covalently hydrophilic bioactive polymers on the surface of implants. In this study, poly(methacrylic acid) (PMAc) and poly(acrylic acid) (PAAc) were chosen as non-toxic and biocompatible bioactive polymers known for reducing bacteria adhesion. These polymers are also good candidates to lend reactivity on the surface for further functionalization. X-ray photoelectron Spectroscopy (XPS) and Fourier-Transform Infrared spectroscopy (FTIR) analysis have highlighted the covalent grafting of these polymers. Apparent water contact angle measurements have shown the change in hydrophilicity on the surface, and a colorimetric assay allowed us to assess the grafting rate of PMAc and PAAc. Tensile strength assays were performed to ensure that the functionalization process does not significantly alter the material’s mechanical properties. Analyses of the surface aspect and roughness by Scanning Electron Microscope (SEM) and optical profilometer allow us to formulate hypotheses to approach the understanding of the behavior of the polymer once grafted.

24 July 2023 in Coatings
Verified
Journal Article
Open access
PDF file
AOAzadeh Valinataj Omran
Azadeh Valinataj Omran
CMchaimaa mahi
chaimaa mahi
RVRomain Vayron
Romain Vayron
CFCéline Falentin-Daudré
Céline Falentin-Daudré
Fabien BénédicFabien Bénédic
Fabien Bénédic
In this study, the characteristics of nanocrystalline diamond films synthesized at low surface temperature on Ti-6Al-4V (TA6V) substrates using a distributed antenna array microwave reactor aiming at biomedical applications were investigated. The surface roughness of the TA6V substrates is varied by scratching with emery paper of 1200, 2400, 4000 polishing grit. Nanocrystalline diamond (NCD) coatings with morphology, purity, and microstructure comparable to those obtained on silicon substrates usually employed in the same reactor and growth conditions are successfully achieved whatever the polishing protocol. However, the latter has a significant effect on the roughness parameters and hardness of the NCD films. The use of the finest polishing grit thus permits us to enhance the hardness value, which can be related to the work-hardening phenomenon arising from the polishing process.

28 October 2022 in Heliyon
Verified
Journal Article
Open access
AJAhmad Jaber
Ahmad Jaber
RVRomain Vayron
Romain Vayron
SHSouad Harmand
Souad Harmand
To characterize various induced phenomena and the blood of healthy sheep using several parameters, the evaporation dynamics of 72 drops of sheep blood evaporated at several temperatures: 23, 37, 60, and 90 °C on glass hydrophilic substrates were studied. This allows the prediction of the sheep blood pattern, knowing the surface temperature and vice versa. To determine the variation in the Marangoni number between the center and the triple line, an infrared thermography method was used to measure the temperature variation along the surface of the drop. Simultaneously, a high-performance camera was used to measure the variation in the height of the drop during the evaporation using a superior algorithm software for image analysis, drop shape analyzer, under controlled conditions (Humidity = 40%, Tatm = 23 °C). The study of the evaporation dynamics and pattern formation shows the effect of temperature on the flow circulation inside the drop, resulting in the final deposit. The results showed two categories corresponding to two different evaporation phenomena induced by the thermal Marangoni effect. Furthermore, to transform the induced pattern of sheep blood evaporation into a 3D image, a topographic study was performed using a highly accurate, fast, and flexible optical 3D measurement system. The topographic parameters were subsequently extracted from these 3D images. The statistical study showed a good correlation between the topographic parameters and the surface temperature, and a significant difference between each temperature group for each parameter.

21 March 2023 in Langmuir
Verified
Journal Article
Closed access
AJAhmad Jaber
Ahmad Jaber
RVRomain Vayron
Romain Vayron
SHSouad Harmand
Souad Harmand