Roberto Grena

Dr. Roberto Grena

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2010 in International Journal of Sustainable Energy
Verified
Journal Article
Closed access
RGRoberto Grena
Roberto Grena
The optical simulation of a linear parabolic solar collector with a tubular receiver is presented. The simulation considers a general model of a trough collector with a pipe receiver, with or without a glass covering, and with a realistic solar irradiation from an arbitrary direction. Optical properties can depend on the wavelength. The simulation is performed using a three-dimensional ray-tracing technique and allows us to follow a ray along all the multiple reflections and refractions that occur at the mirror and at the receiver. Defects of various kinds are simulated. The simulation computes the total optical efficiency, the distribution of the absorbed radiation on the surface of the receiver, and the energy absorbed by the glass covering (if present). The results for a typical trough electric production system are shown and commented upon.

1 August 2021 in Solar Energy
Verified
Journal Article
Closed access
AGAlberto Giaconia
Alberto Giaconia
RGRoberto Grena
Roberto Grena

24 October 2011 in International Journal of Green Energy
Verified
Journal Article
Closed access
RGRoberto Grena
Roberto Grena
In order to reduce the thermal emission from a glass-covered receiver tube of a trough collector, the part of the glass not facing the collector can be covered with an IR-reflecting layer. The advantages of such a covering are discussed in this preliminary study by means of optical and thermal simulations of three configurations of a receiver (two configurations with two different IR-reflecting layers, and one configuration without any IR-reflecting layer). From the simulations, it was observed that one of the layers produce a relative gain of 3.84% of the efficiency over a year (location: south of Italy). An upper bound on the cost of the covering is given.

29 October 2024 in Processes
Verified
Journal Article
Open access
PDF file
MSMehdi Shokrnia
Mehdi Shokrnia
MCMattia Cagnoli
Mattia Cagnoli
RGRoberto Grena
Roberto Grena
ADAntonio D'Angelo
Antonio D'Angelo
MLMichela Lanchi
Michela Lanchi
RZRoberto Zanino
Roberto Zanino
In the context of Concentrated Solar Power (CSP) technology, this paper presents a comparison between the Parabolic Trough Collector (PTC) and the Linear Fresnel Collector (LFC), considering both evacuated and non-evacuated receiver tubes. The comparison was carried out in terms of the Levelized Cost of Electricity (LCOE) considering a reference year and four locations in the world, characterized by different levels of direct normal irradiation (DNI) from 2183 kWh/m2/year to 3409 kWh/m2/year. The LCOE depends on economic parameters and on the net energy generated by a plant on an annual basis. The latter was determined by a steady-state 1D model that solved the energy balance along the receiver axis. This model required computing the incident solar power and heat losses. While the solar power was calculated by an optical ray-tracing model, heat losses were computed by a lumped-parameter model developed along the radial direction of the tube. Since the LFC adopted a secondary concentrator, no conventional correlation was applicable for the convective heat transfer from the glass cover to the environment. Therefore, a 2D steady-state CFD model was also developed to investigate this phenomenon. The results showed that the PTC could generate a higher net annual energy compared to the LFC due to a better optical performance ensured by the parabolic solar collector. Nevertheless, the difference between the PTC and the LFC was lower in the non-evacuated tubes because of lower heat losses from the LFC receiver tube. The economic analysis revealed that the PTC with the evacuated tube also achieved the lowest LCOE, since the higher cost with respect to both the LFC system and the non-evacuated PTC was compensated by the higher net energy yield. However, the non-evacuated LFC demonstrated a slightly lower LCOE compared to the non-evacuated PTC since the lower capital cost of the non-evacuated LFC outweighed its lower net annual energy yield. Finally, a sensitivity analysis was conducted to assess the impact on the LCOE of the annual optical efficiency and of the economic parameters. This study introduces key technical parameters in LFC technology requiring improvement to achieve the level of productivity of the PTC from a techno-economic viewpoint, and consequently, to fill the gap between the two technologies.

31 October 2011 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
RGRoberto Grena
Roberto Grena
MCMassimo Celino
Massimo Celino
PTPietro Tarquini
Pietro Tarquini

17 April 2025 in Energies
Verified
Journal Article
Open access
PDF file
RGRoberto Grena
Roberto Grena
MCMattia Cagnoli
Mattia Cagnoli
RZRoberto Zanino
Roberto Zanino
MLMichela Lanchi
Michela Lanchi
The expected increase in energy production from VRE (Variable Renewable Energy) requires a significant increase in energy storage capacity, with thermal storage potentially offering a key contribution. However, heat transfer mechanisms can limit the maximum power instantaneously transferable to the storage medium, posing a significant operational challenge. An analysis is presented here of the power limitations that arise when molten salt thermal storage adopting Solar Salt (NaNO3/KNO3, 60/40%wt) is heated by electrical resistances (Joule heating), and a possible alternative—the volumetric heating of the salt mass by microwaves—is discussed. Results show that microwave heating is an interesting path to overcome the power limitations of Joule heating. A first, theoretical analysis indicates a potential increase of more than 10 times in the maximum power transferable per unit area. Thermal-fluid-dynamic and electromagnetic models have been developed to numerically test the performance of a one-tank thermocline system endowed with a microwave heater. The proposed heating system showed limitations in terms of the maximum power that can be transferred to the salt because of the high temperatures established in the boundary layer. Finally, it performs in a comparable way with respect to an (ideal) heating system based on the Joule effect. However, many design improvements can still be adopted to enhance the performance of the proposed technology, likely overcoming the performance reachable using Joule heating systems.