We demonstrate a novel and simple means to fabricate optical fiber immunosensors based on Fabry-Perot (F-P) interferometers using polydimethylsiloxane (PDMS) as support for bioactive lipids. The sensors are fabricated following a straightforward dip-coating method producing PDMS end-capped devices. A biosensing platform is realized by subsequent functionalization of the PDMS cap with a previously characterized bioactive lipid antigen cocktail from Mycobacterium fortuitum, used as a surrogate source of antigens for tuberculosis diagnosis. After functionalization of the PDMS, the F-P sensors were immersed in different antibody-containing sera and the registered changes in their spectral features were associated to the interactions between the active lipids and the serum antibodies. Our results show that the proposed PDMS end-capped F-P immunosensors perform well differentiating antibody-containing sera. Furthermore, they offer attractive attributes such as label-free operation, real-time detection capabilities and they are also reusable. The proposed sensors, therefore, serve as an enabling optical immunosensing technique offering excellent potential for developing novel lipidomic analytical tools.
Laser speckle imaging (LSI) of mouse cerebral blood flow was compared through a transparent nanocrystalline yttria-stabilized zirconia (nc-YSZ) cranial implant over time (at days 0, 14, and 28, n = 3 mice), and vs. LSI through native skull (at day 60, n = 1 mouse). The average sharpness of imaged vessels was found to remain stable, with relative change in sharpness under 7.69% ± 1.2% over 28 days. Through-implant images of vessels at day 60 appeared sharper and smaller on average, with microvessels clearly visible, compared to through-skull images where vessels appeared blurred and distorted. These results suggest that long-term imaging through this implant is feasible.
We report on a simple fabrication technique for Fabry–Perot (FP) sensors formed by a microbubble within a polymer drop deposited on the tip of an optical fiber. Polydimethylsiloxane (PDMS) drops are deposited on the tips of standard single-mode fibers incorporating a layer of carbon nanoparticles (CNPs). A microbubble inside this polymer end-cap, aligned along the fiber core, can be readily generated on launching light from a laser diode through the fiber, owing to the photothermal effect produced in the CNP layer. This approach allows for the fabrication of microbubble end-capped FP sensors with reproducible performance, showing temperature sensitivities as large as 790 pm/°C, larger than those reported for regular polymer end-capped devices. We further show that these microbubble FP sensors may also prove useful for displacement measurements, with a sensitivity of ∼5.4 nm/µm.
We demonstrate fiber optic sensors with temperature compensation for the accurate measurement of ethanol concentration in aqueous solutions. The device consists of two photonic crystal (PhC) fiber-tip sensors: one measures the ethanol concentration via refractive index (RI) changes and the other one is isolated from the liquid for the independent measurement of temperature. The probes utilize an optimized PhC design providing a Lorentzian-like, polarization-independent response, enabling a very low imprecision (pm-level) in the wavelength determination. By combining the information from the two probes, it is possible to compensate for the effect that the temperature has on the concentration measurement, obtaining more accurate estimations of the ethanol concentration in a broad range of temperatures. We demonstrate the simultaneous and single-point measurements of temperature and ethanol concentration in water, with sensitivities of 19 pm/°C and ∼53 pm/%, in the ranges of 25 °C to 55 °C and 0 to (at 25 °C), respectively. Moreover, a maximum error of in the concentration measurement, with a standard deviation of ≤0.8%, was obtained in the entire temperature range after compensating for the effect of temperature. A limit of detection as low as was demonstrated for the concentration measurement in temperature-stable conditions.
We report on the enhanced optical transmittance in the NIR wavelength range (900 to 2400 nm) offered by a transparent Yttria-stabilized zirconia (YSZ) implant coupled with optical clearing agents (OCAs). The enhancement in optical access to the brain is evaluated upon comparing ex-vivo transmittance measurements of mice native skull and the YSZ cranial implant with scalp and OCAs. An increase in transmittance of up to 50% and attenuation lengths of up to 2.4 mm (i.e., a five-fold increase in light penetration) are obtained with the YSZ implant and the OCAs. The use of this ceramic implant and the biocompatible optical clearing agents offer attractive features for NIR optical techniques for brain theranostics.
Sensing nano-objects, from nanoparticles to molecules, has become a crucial need in environmental monitoring, medical diagnostics, and drug development. Detection of single particles and molecules is highly desirable, as it provides specific information on size, dynamics, and interactions. Current nanophotonic implementations rely on complex optical readout schemes, limiting their application in the field. Here we demonstrate a nanophotonic fiber-tip sensor with a compact sensor footprint and a simple readout scheme. We leverage advanced design methods to simultaneously achieve a small mode volume Vm=0.74(λ/n)3, narrow linewidth Δλ=0.4nm, and a large modulation ΔR≈20% in reflection from the fiber. This unique combination of properties opens the way to sensing weak nanoscale perturbations in the vicinity of the fiber tip. In particular, we experimentally demonstrate the real-time detection of single 50 nm nanoparticles. This opens a route towards real-time sensing of single nanoparticles, and potentially single molecules, in environmental monitoring and diagnostics.