The blood-brain barrier (BBB), a selective barrier regulating the active and passive transport of solutes in the extracellular fluid of the central nervous system, prevents the delivery of therapeutics for brain disorders. The BBB is composed of brain microvascular endothelial cells (BMEC), pericytes and astrocytes. Current in vitro BBB models cannot reproduce the human structural complexity of the brain microvasculature, and thus their functions are not enough for drug assessments. In this study, we developed a 3D self-assembled microvascular network formed by BMEC covered by pericytes and astrocyte end feet. It exhibited perfusable microvasculature due to the presence of capillary opening ends on the bottom of the hydrogel. It also demonstrated size-selective permeation of different molecular weights of fluorescent-labeled dextran, as similarly reported for in vivo rodent brain, suggesting the same permeability with actual in vivo brain. The activity of P-glycoprotein efflux pump was confirmed using the substrate Rhodamine 123. Finally, the functionality of the receptor-mediated transcytosis, one of the main routes for drug delivery of large molecules into the brain, could be validated using transferrin receptor (TfR) with confocal imaging, competition assays and permeability assays. Efficient permeability coefficient (Pe) value of transportable anti-TfR antibody (MEM-189) was seven-fold higher than those of isotype antibody (IgG1) and low transportable anti-TfR antibody (13E4), suggesting a higher TfR transport function than previous reports. The BBB model with capillary openings could thus be a valuable tool for the screening of therapeutics that can be transported across the BBB, including those using TfR-mediated transport.
Partially deuterated telluric acid ammonium phosphate (TAAP) single crystals were grown from water solutions with various H2O and D2O ratios. The transition temperature TC was determined from the dielectric anomaly characteristic to the second order phase transition. Deuteration molar fraction xc in the crystal was determined by a mass spectrograph. It was proved that TC increases almost linearly with xc. The maximum transition temperature reached 357 K for xc = 0.73. The deuteration effect in TAAP is clearly smaller than that in the typical hydrogen-bonded ferroelectrics such as KDP-type but considerably larger than TGS-type ferroelectrics.
The blood–brain barrier (BBB) is a selective barrier that controls the transport between the blood and neural tissue features and maintains brain homeostasis to protect the central nervous system (CNS). In vitro models can be useful to understand the role of the BBB in disease and assess the effects of drug delivery. Recently, we reported a 3D BBB model with perfusable microvasculature in a Transwell insert. It replicates several key features of the native BBB, as it showed size-selective permeability of different molecular weights of dextran, activity of the P-glycoprotein efflux pump, and functionality of receptor-mediated transcytosis (RMT), which is the most investigated pathway for the transportation of macromolecules through endothelial cells of the BBB. For quality control and permeability evaluation in commercial use, visualization and quantification of the 3D vascular lumen structures is absolutely crucial. Here, for the first time, we report a rapid, non-invasive optical coherence tomography (OCT)-based approach to quantify the microvessel network in the 3D in vitro BBB model. Briefly, we successfully obtained the 3D OCT images of the BBB model and further processed the images using three strategies: morphological imaging processing (MIP), random forest machine learning using the Trainable Weka Segmentation plugin (RF-TWS), and deep learning using pix2pix cGAN. The performance of these methods was evaluated by comparing their output images with manually selected ground truth images. It suggested that deep learning performed well on object identification of OCT images and its computation results of vessel counts and surface areas were close to the ground truth results. This study not only facilitates the permeability evaluation of the BBB model but also offers a rapid, non-invasive observational and quantitative approach for the increasing number of other 3D in vitro models.
Microphysiological systems (MPSs) have emerged as alternatives to animal testing in drug development, following the FDA Modernization Act 2.0. Double-layer channel-type MPS chips with porous membranes are widely used for modeling various organs, including the intestines, blood–brain barrier, renal tubules, and lungs. However, these chips faced challenges owing to optical interference caused by light scattering from the porous membrane, which hinders cell observation. Trans-epithelial electrical resistance (TEER) measurement offers a non-invasive method for assessing barrier integrity in these chips. However, existing electrode-integrated MPS chips for TEER measurement have non-uniform current densities, leading to compromised measurement accuracy. Additionally, chips made from polydimethylsiloxane have been associated with drug absorption issues. This study developed an electrode-integrated MPS chip for TEER measurement with a uniform current distribution and minimal drug absorption. Through a finite element method simulation, electrode patterns were optimized and incorporated into a polyethylene terephthalate (PET)-based chip. The device was fabricated by laminating PET films, porous membranes, and patterned gold electrodes. The chip’s performance was evaluated using a perfused Caco-2 intestinal model. TEER levels increased and peaked on day 5 when cells formed a monolayer, and then they decreased with the development of villi-like structures. Concurrently, capacitance increased, indicating microvilli formation. Exposure to staurosporine resulted in a dose-dependent reduction in TEER, which was validated by immunostaining, indicating a disruption of the tight junction. This study presents a TEER measurement MPS platform with a uniform current density and reduced drug absorption, thereby enhancing TEER measurement reliability. This system effectively monitors barrier integrity and drug responses, demonstrating its potential for non-animal drug-testing applications.
Light-field three-dimensional (3D) fluorescence microscopes can acquire 3D fluorescence images in a single shot, and followed numerical reconstruction can realize cross-sectional imaging at an arbitrary depth. The typical configuration that uses a lens array and a single image sensor has the trade-off between depth information acquisition and spatial resolution of each cross-sectional image. The spatial resolution of the reconstructed image degrades when depth information increases. In this paper, we use U-net as a deep learning model to improve the quality of reconstructed images. We constructed an optical system that integrates a light-field microscope and an epifluorescence microscope, which acquire the light-field data and high-resolution two-dimensional images, respectively. The high-resolution images from the epifluorescence microscope are used as ground-truth images for the training dataset for deep learning. The experimental results using fluorescent beads with a size of 10 µm and cultured tobacco cells showed significant improvement in the reconstructed images. Furthermore, time-lapse measurements were demonstrated in tobacco cells to observe the cell division process.
A spectral-domain optical coherence microscope (SD-OCM) embedded by a digital phase conjugation is presented for high-resolution imaging of objects behind a weakly scattering medium. For high-resolution SD-OCM, keeping a narrow focusing spot even in a scattering medium is important. To compensate for the degradation of the focused spot due to the scattering, digital phase conjugation with a low-coherent light is introduced by measuring the distorted wavefront of coherent light and making wavelength conversion due to the difference between the coherent and low-coherent light beams. Experiments using a weakly scattering sheet with a scattering angle of 30 degrees showed us to improve the focused spot property and enhance the reflected intensity signal. We also demonstrate the feasibility of the system for the imaging of objects with periodic reflectance structures of 10 µm width.