Chenyun Dai

Dr. Chenyun Dai


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
XJXinyu Jiang
Xinyu Jiang
XLXiangyu Liu
Xiangyu Liu
JFJiahao Fan
Jiahao Fan
XYXinming Ye
Xinming Ye
CDChenyun Dai
Chenyun Dai
Wei ChenWei Chen
Wei Chen
We provide an open access dataset of High densitY Surface Electromyogram (HD-sEMG) Recordings (named “Hyser”), a toolbox for neural interface research, and benchmark results for pattern recognition and EMG-force applications. Data from 20 subjects were acquired twice per subject on different days following the same experimental paradigm. We acquired 256-channel HD-sEMG from forearm muscles during dexterous finger manipulations. This Hyser dataset contains five sub-datasets as: (1) pattern recognition (PR) dataset acquired during 34 commonly used hand gestures, (2) maximal voluntary muscle contraction (MVC) dataset while subjects contracted each individual finger, (3) one-degree of freedom (DoF) dataset acquired during force-varying contraction of each individual finger, (4) N-DoF dataset acquired during prescribed contractions of combinations of multiple fingers, and (5) random task dataset acquired during random contraction of combinations of fingers without any prescribed force trajectory. Dataset 1 can be used for gesture recognition studies. Datasets 2-5 also recorded individual finger forces, thus can be used for studies on proportional control of neuroprostheses. Our toolbox can be used to: (1) analyze each of the five datasets using standard benchmark methods and (2) decompose HD-sEMG signals into motor unit action potentials via independent component analysis. We expect our dataset, toolbox and benchmark analyses can provide a unique platform to promote a wide range of neural interface research and collaboration among neural rehabilitation engineers.

1 February 2021 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
YGYao Guo
Yao Guo
XLXiangyu Liu
Xiangyu Liu
SPShun Peng
Shun Peng
XJXinyu Jiang
Xinyu Jiang
KXKe Xu
Ke Xu
Wei ChenWei Chen
Wei Chen

2 July 2019 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
CDChenyun Dai
Chenyun Dai
XHXiaogang Hu
Xiaogang Hu
Estimation of joint kinematics plays an important role in intuitive human-machine interactions. However, continuous and reliable estimation of small (e.g., the finger) joint angles is still a challenge. The objective of this study was to continuously estimate finger joint angles using populational motoneuron firing activities. Multi-channel surface electromyogram (sEMG) signals were obtained from the extensor digitorum communis muscles, while the subjects performed individual finger oscillatory extension movements at two different speeds. The individual finger movement was first classified based on the EMG signals. The discharge timings of individual motor units were extracted through high-density sEMG decomposition, and were then pooled as a composite discharge train. The firing frequency of the populational motor unit firing events was used to represent the descending neural drive to the motor unit pool. A second-order polynomial regression was then performed to predict the measured metacarpophalangeal extension angle using the derived neural drive based on the neuronal firings. Our results showed that individual finger extension movement can be classified with > 96% accuracy based on multi-channel EMG. The extension angles can be predicted continuously by the derived neural drive with R2 values > 0.8. The performance of the neural-drive-based approach was superior to the classic EMG-amplitude-based approach, especially during fast movements. These findings indicated that the neural-drive-based interface was a promising approach to reliably predict individual finger kinematics.

30 March 2022 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
YGYao Guo
Yao Guo
XJXinyu Jiang
Xinyu Jiang
LTLinkai Tao
Linkai Tao
LMLong Meng
Long Meng
CDChenyun Dai
Chenyun Dai
Chen ChenChen Chen
Chen Chen
The electroencephalogram (EEG), for measuring the electrophysiological activity of the brain, has been widely applied in automatic detection of epilepsy seizures. Various EEG-based seizure detection algorithms have already yielded high sensitivity, but training those algorithms requires a large amount of labelled data. Data labelling is often done with a lot of human efforts, which is very time-consuming. In this study, we propose a hybrid system integrating an unsupervised learning (UL) module and a supervised learning (SL) module, where the UL module can significantly reduce the workload of data labelling. For preliminary seizure screening, UL synthesizes amplitude-integrated EEG (aEEG) extraction, isolation forest-based anomaly detection, adaptive segmentation, and silhouette coefficient-based anomaly detection evaluation. The UL module serves to quickly locate the determinate subjects (seizure segments and seizure-free segments) and the indeterminate subjects (potential seizure candidates). Afterwards, more robust seizure detection for the indeterminate subjects is performed by the SL using an EasyEnsemble algorithm. EasyEnsemble, as a class-imbalance learning method, can potentially decrease the generalization error of the seizure-free segments. The proposed method can significantly reduce the workload of data labelling while guaranteeing satisfactory performance. The proposed seizure detection system is evaluated using the Children’s Hospital Boston-Massachusetts Institute of Technology (CHB-MIT) scalp EEG dataset, and it achieves a mean accuracy of 92.62%, a mean sensitivity of 95.55%, and a mean specificity of 92.57%. To the best of our knowledge, this is the first epilepsy seizure detection study employing the integration of both the UL and the SL modules, achieving a competitive performance superior or similar to that of the state-of-the-art methods.

22 April 2021 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
XJXinyu Jiang
Xinyu Jiang
XLXiangyu Liu
Xiangyu Liu
JFJiahao Fan
Jiahao Fan
XYXinming Ye
Xinming Ye
CDChenyun Dai
Chenyun Dai
Wei ChenWei Chen
Wei Chen
Enhancing information security via reliable user authentication in wireless body area network (WBAN)-based Internet-of-Things (IoT) applications has attracted increasing attention. The noncancelability of traditional biometrics (e.g., fingerprint) for user authentication increases the privacy disclosure risks once the biometric template is exposed, because users cannot volitionally create a new template. In this work, we propose a cancelable biometric modality based on high-density surface electromyogram (HD-sEMG) encoded by hand gesture password, for user authentication. HD-sEMG signals (256 channels) were acquired from the forearm muscles when users performed a prescribed gesture password, forming their biometric token. Thirty four alternative hand gestures in common daily use were studied. Moreover, to reduce the data acquisition and transmission burden in IoT devices, an automatically generated password-specific channel mask was employed to reduce the number of active channels. HD-sEMG biometrics were also robust with reduced sampling rate, further reducing power consumption. HD-sEMG biometrics achieved a low equal error rate (EER) of 0.0013 when impostors entered a wrong gesture password, as validated on 20 subjects. Even if impostors entered the correct gesture password, the HD-sEMG biometrics still achieved an EER of 0.0273. If the HD-sEMG biometric template was exposed, users could cancel it by simply changing it to a new gesture password, with an EER of 0.0013. To the best of our knowledge, this is the first study to employ HD-sEMG signals under common daily hand gestures as biometric tokens, with training and testing data acquired on different days.

1 October 2020 in Journal of Neural Engineering
Verified
Journal Article
Closed access
JFJiahao Fan
Jiahao Fan
CSChenglu Sun
Chenglu Sun
Chen ChenChen Chen
Chen Chen
XJXinyu Jiang
Xinyu Jiang
XLXiangyu Liu
Xiangyu Liu
WCWei Chen
Wei Chen
Objective. Automatic sleep staging models suffer from an inherent class imbalance problem (CIP), which hinders the classifiers from achieving a better performance. To address this issue, we systematically studied sleep electroencephalogram data augmentation (DA) approaches. Furthermore, we modified and transferred novel DA approaches from related research fields, yielding new efficient ways to enhance sleep datasets. Approach. This study covers five DA methods, including repeating minority classes, morphological change, signal segmentation and recombination, dataset-to-dataset transfer, as well as generative adversarial network (GAN). We evaluated these mentioned DA methods by a sleep staging model on two datasets, the Montreal archive of sleep studies (MASS) and Sleep-EDF. We used a classification model with a typical convolutional neural network architecture to evaluate the effectiveness of the mentioned DA approaches. We also conducted a comprehensive analysis of these methods. Main results. The classification results showed that DA methods, especially DA by GAN, significantly improved the total classification performance in comparison with the baseline. The improvement of accuracy, F1 score and Cohen Kappa coefficient range from 0.90% to 3.79%, 0.73% to 3.48%, 2.61% to 5.43% on MASS and 1.36% to 4.79%, 1.47% to 4.23%, 2.22% to 4.04% on Sleep-EDF, respectively. DA methods improved the classification performance in most cases, whereas the performance of class N1 showed a subtle degradation in the F1 scores. Significance. Overall, our study proved that DA approaches are efficient in alleviating CIP lying in sleep staging tasks. Meanwhile, this study provided avenues for further improving the sleep staging accuracy using DA methods.