Jiahao Fan

Jiahao Fan

Auto-generated profile, based on publicly available information

Jiahao Fan

Department of Mechanical Engineering, Pennsylvania State University, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
XJXinyu Jiang
Xinyu Jiang
XLXiangyu Liu
Xiangyu Liu
JFJiahao Fan
Jiahao Fan
XYXinming Ye
Xinming Ye
CDChenyun Dai
Chenyun Dai
Wei ChenWei Chen
Wei Chen
We provide an open access dataset of High densitY Surface Electromyogram (HD-sEMG) Recordings (named “Hyser”), a toolbox for neural interface research, and benchmark results for pattern recognition and EMG-force applications. Data from 20 subjects were acquired twice per subject on different days following the same experimental paradigm. We acquired 256-channel HD-sEMG from forearm muscles during dexterous finger manipulations. This Hyser dataset contains five sub-datasets as: (1) pattern recognition (PR) dataset acquired during 34 commonly used hand gestures, (2) maximal voluntary muscle contraction (MVC) dataset while subjects contracted each individual finger, (3) one-degree of freedom (DoF) dataset acquired during force-varying contraction of each individual finger, (4) N-DoF dataset acquired during prescribed contractions of combinations of multiple fingers, and (5) random task dataset acquired during random contraction of combinations of fingers without any prescribed force trajectory. Dataset 1 can be used for gesture recognition studies. Datasets 2-5 also recorded individual finger forces, thus can be used for studies on proportional control of neuroprostheses. Our toolbox can be used to: (1) analyze each of the five datasets using standard benchmark methods and (2) decompose HD-sEMG signals into motor unit action potentials via independent component analysis. We expect our dataset, toolbox and benchmark analyses can provide a unique platform to promote a wide range of neural interface research and collaboration among neural rehabilitation engineers.

22 April 2021 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
XJXinyu Jiang
Xinyu Jiang
XLXiangyu Liu
Xiangyu Liu
JFJiahao Fan
Jiahao Fan
XYXinming Ye
Xinming Ye
CDChenyun Dai
Chenyun Dai
Wei ChenWei Chen
Wei Chen
Enhancing information security via reliable user authentication in wireless body area network (WBAN)-based Internet-of-Things (IoT) applications has attracted increasing attention. The noncancelability of traditional biometrics (e.g., fingerprint) for user authentication increases the privacy disclosure risks once the biometric template is exposed, because users cannot volitionally create a new template. In this work, we propose a cancelable biometric modality based on high-density surface electromyogram (HD-sEMG) encoded by hand gesture password, for user authentication. HD-sEMG signals (256 channels) were acquired from the forearm muscles when users performed a prescribed gesture password, forming their biometric token. Thirty four alternative hand gestures in common daily use were studied. Moreover, to reduce the data acquisition and transmission burden in IoT devices, an automatically generated password-specific channel mask was employed to reduce the number of active channels. HD-sEMG biometrics were also robust with reduced sampling rate, further reducing power consumption. HD-sEMG biometrics achieved a low equal error rate (EER) of 0.0013 when impostors entered a wrong gesture password, as validated on 20 subjects. Even if impostors entered the correct gesture password, the HD-sEMG biometrics still achieved an EER of 0.0273. If the HD-sEMG biometric template was exposed, users could cancel it by simply changing it to a new gesture password, with an EER of 0.0013. To the best of our knowledge, this is the first study to employ HD-sEMG signals under common daily hand gestures as biometric tokens, with training and testing data acquired on different days.

1 October 2020 in Journal of Neural Engineering
Verified
Journal Article
Closed access
JFJiahao Fan
Jiahao Fan
CSChenglu Sun
Chenglu Sun
Chen ChenChen Chen
Chen Chen
XJXinyu Jiang
Xinyu Jiang
XLXiangyu Liu
Xiangyu Liu
WCWei Chen
Wei Chen
Objective. Automatic sleep staging models suffer from an inherent class imbalance problem (CIP), which hinders the classifiers from achieving a better performance. To address this issue, we systematically studied sleep electroencephalogram data augmentation (DA) approaches. Furthermore, we modified and transferred novel DA approaches from related research fields, yielding new efficient ways to enhance sleep datasets. Approach. This study covers five DA methods, including repeating minority classes, morphological change, signal segmentation and recombination, dataset-to-dataset transfer, as well as generative adversarial network (GAN). We evaluated these mentioned DA methods by a sleep staging model on two datasets, the Montreal archive of sleep studies (MASS) and Sleep-EDF. We used a classification model with a typical convolutional neural network architecture to evaluate the effectiveness of the mentioned DA approaches. We also conducted a comprehensive analysis of these methods. Main results. The classification results showed that DA methods, especially DA by GAN, significantly improved the total classification performance in comparison with the baseline. The improvement of accuracy, F1 score and Cohen Kappa coefficient range from 0.90% to 3.79%, 0.73% to 3.48%, 2.61% to 5.43% on MASS and 1.36% to 4.79%, 1.47% to 4.23%, 2.22% to 4.04% on Sleep-EDF, respectively. DA methods improved the classification performance in most cases, whereas the performance of class N1 showed a subtle degradation in the F1 scores. Significance. Overall, our study proved that DA approaches are efficient in alleviating CIP lying in sleep staging tasks. Meanwhile, this study provided avenues for further improving the sleep staging accuracy using DA methods.

18 January 2022 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
JFJiahao Fan
Jiahao Fan
HYHaun Yu
Haun Yu
XJXinyu Jiang
Xinyu Jiang
LMLong Meng
Long Meng
Chen ChenChen Chen
Chen Chen
Wei ChenWei Chen
Wei Chen
Deep sleep staging networks have reached top performance on large-scale datasets. However, these models perform poorer when training and testing on small sleep cohorts due to data inefficiency. Transferring well-trained models from large-scale datasets (source domain) to small sleep cohorts (target domain) is a promising solution but still remains challenging due to the domain-shift issue. In this work, an unsupervised domain adaptation approach, domain statistics alignment (DSA), is developed to bridge the gap between the data distribution of source and target domains. DSA adapts the source models on the target domain by modulating the domain-specific statistics of deep features stored in the Batch Normalization (BN) layers. Furthermore, we have extended DSA by introducing cross-domain statistics in each BN layer to perform DSA adaptively (AdaDSA). The proposed methods merely need the well-trained source model without access to the source data, which may be proprietary and inaccessible. DSA and AdaDSA are universally applicable to various deep sleep staging networks that have BN layers. We have validated the proposed methods by extensive experiments on two state-of-the-art deep sleep staging networks, DeepSleepNet+ and U-time. The performance was evaluated by conducting various transfer tasks on six sleep databases, including two large-scale databases, MASS and SHHS, as the source domain, four small sleep databases as the target domain. Thereinto, clinical sleep records acquired in Huashan Hospital, Shanghai, were used. The results show that both DSA and AdaDSA could significantly improve the performance of source models on target domains, providing novel insights into the domain generalization problem in sleep staging tasks.

22 January 2021 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
HDHaikang Diao
Haikang Diao
Chen ChenChen Chen
Chen Chen
WYWei Yuan
Wei Yuan
AAAmara Amara
Amara Amara
Toshiyo TamuraToshiyo Tamura
Toshiyo Tamura
Wei ChenWei Chen
Wei Chen
Sleep posture, as a crucial index for sleep quality assessment, has been widely studied in sleep analysis. In this paper, an unobtrusive smart mat system based on a dense flexible sensor array and printed electrodes along with an algorithmic framework for sleep posture recognition is proposed. With the dense flexible sensor array, the system offers a comfortable and high-resolution solution for long-term pressure sensing. Meanwhile, compared to other methods, it reduces production costs and computational complexity with a smaller area of the mat and improves portability with fewer sensors. To distinguish the sleep posture, the algorithmic framework that includes preprocessing and Deep Residual Networks (ResNet) is developed. With the ResNet, the proposed system can omit the complex hand-crafted feature extraction process and provide compelling performance. The feasibility and reliability of the proposed system were evaluated on seventeen subjects. Experimental results exhibit that the accuracy of the short-term test is up to 95.08% and the overnight sleep study is up to 86.35% for four categories (supine, prone, right, and left) classification, which outperform the most of state-of-the-art studies. With the promising results, the proposed system showed great potential in applications like sleep studies, prevention of pressure ulcers, etc.

28 October 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LMLong Meng
Long Meng
XJXinyu Jiang
Xinyu Jiang
XLXiangyu Liu
Xiangyu Liu
JFJiahao Fan
Jiahao Fan
HRHaoran Ren
Haoran Ren
Wei ChenWei Chen
Wei Chen
Surface electromyogram (sEMG) based hand gesture recognition for prosthesis or armband is an important application of the human-machine interface. However, the measurement location of sensors greatly influences the hand gesture performance, especially with the inter-day or inter-subject validation protocols. Therefore, we acquired two-day hand gesture data of 41 subjects with a 256 (16×16) channel high-density sEMG electrode array. With the acquired data, we initially compared the support vector machine (SVM) and other four state-of-art classifiers under three validation protocols, i.e., intra-day, inter-day and inter-subject validation protocols. Then, we screened 14 feature optimization techniques, including 5 feature-projection methods and 9 feature-ranking approaches. To present the accuracy tendency with varying measure locations, we systematically explored the 10-hand gesture performance using data of 16 prosthesis measurement locations (PMLs) and 15 armband measurement locations (AMLs). As a result, the SVM classifier was suitable for the intra-day and inter-day validation protocols and the 2-dimensional convolutional neural network was selected for the inter-subject validation protocol. The mean accuracies of the hand gesture classification ranged from 95.68% to 99.12% (intra-day validation), from 68.41% to 88.02% (inter-day validation) and from 63.39% to 86.33% (inter-subject validation) for the prosthesis application. In addition, for the armband application, the mean accuracies ranged from 96.25% to 97.43% (intra-day validation), from 67.44% to 75.83% (inter-day validation) and from 65.53% to 75.40% (inter-subject validation). The accuracy is greatly correlated with the measurement location, which is highly associated with the neuromuscular structures of human bodies. In summary, our work can serve as a factor-screening tool for users customizing their systems according to their physical conditions and requirements.