The measurement of ion mobility is important for calculating the corona loss of the transmission lines, and for establishing corona loss and ion current models that take humidity and air pressure into consideration. This paper describes a needle-ring...
The corona onset characteristic of bundle conductors is an important limiting factor for the design of UHV AC power lines in high-altitude areas. An experimental study on the corona characteristics of 8 × LGJ630, 6 × LGJ720, 8 × LGJ720 and 10 × LGJ720 bundle conductors commonly used in UHV power lines under dry and wet conductor conditions, as well as artificial moderate and heavy rain conditions, was conducted in Ping’an County, Xining City (elevation 2200 m). By using the tangent line method, the corona onset voltages and onset electric field of four types of conductors at high altitudes are obtained for the first time. In addition, the calculation model of corona onset voltage considering the outer strands’ effect on the electric field and the geometric factor in the corona cage in high altitude areas is established. The comparison of the calculation results and experimental results under dry conditions verifies the model’s correctness. Based on the results, an optimal selection scheme for high altitudes is proposed. The roughness coefficient was also calculated and analysed: the roughness coefficient of bundled conductors was between 0.59 and 0.77, and the roughness coefficient of the wet conductor was between the dry and rainy conditions. Both the experimental data and the calculation model can provide a reference for conductor selection for UHV AC power lines for use in high-altitude areas.
As an important index for measuring the operational economy of EHV AC transmission lines, corona loss (CL) is one of important factors worth considering during the operation and design of transmission lines. The 750-kV transmission lines are mainly distributed in high-altitude areas in northwestern China, where sand storm occurs frequently in spring and autumn. At present, a few researches are available on the evaluation of CL in multi-circuit transmission lines on the same tower in sandy and dusty area at high altitudes. Based on a transmission project with four-circuit transmission lines on the same tower in the north of Xi’an, Shaanxi Province, China, the electric field distributions of bundle conductors under two types of arrangement structure, including six and four cross-arms tower, were investigated. Then, by using the CL equivalent theory, the CL under meteorological conditions of fair, rainy, snowy, foggy, and dusty weather were evaluated. Finally, the optimal phase-sequence arrangement under the optimal tower modes was proposed, and the CL and resistance loss under the selected arrangements were compared.