Sarah Christine Rosemas

Ms. Sarah Christine Rosemas

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2021 in JMIR Cardio
Verified
Journal Article
Open access
ASAmber Seiler
Amber Seiler
EBEliana Biundo
Eliana Biundo
MBMarco Di Bacco
Marco Di Bacco
SRSarah Christine Rosemas
Sarah Christine Rosemas
ENEmmanuelle Nicolle
Emmanuelle Nicolle
LHLaura Van Heel
Laura Van Heel
Background: The number of patients with cardiac implantable electronic device (CIED) is increasing, creating a substantial workload for device clinics. Objective: This study aims to characterize the workflow and quantify clinic staff time requirements for managing patients with CIEDs. Methods: A time and motion workflow evaluation was performed in 11 US and European CIEDs clinics. Workflow tasks were repeatedly timed during 1 business week of observation at each clinic; these observations included all device models and manufacturers. The mean cumulative staff time required to review a remote device transmission and an in-person clinic visit were calculated, including all necessary clinical and administrative tasks. The annual staff time to manage a patient with a CIED was modeled using CIED transmission volumes, clinical guidelines, and the published literature. Results: A total of 276 in-person clinic visits and 2173 remote monitoring activities were observed. Mean staff time required per remote transmission ranged from 9.4 to 13.5 minutes for therapeutic devices (pacemaker, implantable cardioverter-defibrillator, and cardiac resynchronization therapy) and from 11.3 to 12.9 minutes for diagnostic devices such as insertable cardiac monitors (ICMs). Mean staff time per in-person visit ranged from 37.8 to 51.0 and from 39.9 to 45.8 minutes for therapeutic devices and ICMs, respectively. Including all remote and in-person follow-ups, the estimated annual time to manage a patient with a CIED ranged from 1.6 to 2.4 hours for therapeutic devices and from 7.7 to 9.3 hours for ICMs. Conclusions: The CIED patient management workflow is complex and requires significant staff time. Understanding process steps and time requirements informs the implementation of efficiency improvements, including remote solutions. Future research should examine heterogeneity in patient management processes to identify the most efficient workflow.

30 July 2024 in Circulation
Verified
Journal Article
Open access
GPGraham Peigh
Graham Peigh
JZJiani Zhou
Jiani Zhou
SRSarah Christine Rosemas
Sarah Christine Rosemas
ARAnthony I. Roberts
Anthony I. Roberts
CLColleen Longacre
Colleen Longacre
RPRod S. Passman
Rod S. Passman
BACKGROUND: Current estimates of atrial fibrillation (AF)–associated mortality rely on claims- or clinical-derived diagnoses of AF, limit AF to a binary entity, or are confounded by comorbidities. The objective of the present study is to assess the association between device-recognized AF and mortality among patients with cardiac implantable electronic devices capable of sensitive and continuous atrial arrhythmia detection. Secondary outcomes include relative mortality among cohorts with no AF, paroxysmal AF, persistent AF, and permanent AF. METHODS: Using the deidentified Optum Clinformatics US claims database (2015 to 2020) linked to the Medtronic CareLink database, we identified individuals with a cardiac implantable electronic device who transmitted data ≥6 months after implantation. AF burden was assessed during the first 6 months after implantation (baseline period). Subsequent mortality, assessed from claims data, was compared between patients with and without AF, with adjustment for age, geographic region, insurance type, Charlson Comorbidity Index, and implantation year. RESULTS: Of 21 391 patients (age, 72.9±10.9 years; 56.3% male) analyzed, 7798 (36.5%) had device-recognized AF. During a mean of 22.4±12.9 months (median, 20.1 [12.8–29.7] months) of follow-up, the overall incidence of mortality was 13.5%. Patients with AF had higher adjusted all-cause mortality than patients without AF (hazard ratio, 1.29 [95% CI, 1.20–1.39]; P <0.001). Among those with AF, patients with nonparoxysmal AF had the greatest risk of mortality (persistent AF versus paroxysmal AF: hazard ratio, 1.36 [95% CI, 1.18–1.58]; P <.001; permanent AF versus paroxysmal AF: hazard ratio, 1.23 [95% CI, 1.14–1.34]; P <.001). CONCLUSIONS: After adjustment for potential confounding factors, the presence of AF was associated with higher mortality in our cohort of patients with cardiac implantable electronic devices. Among those with AF, nonparoxysmal AF was associated with the greatest risk of mortality.

13 February 2022 in Heart Rhythm O2
Verified
Journal Article
Open access
SYShadi Yaghi
Shadi Yaghi
MRMichael P. Ryan
Michael P. Ryan
CGCandace L. Gunnarsson
Candace L. Gunnarsson
WIWilliam Irish
William Irish
SRSarah Christine Rosemas
Sarah Christine Rosemas
MRMatthew R. Reynolds
Matthew R. Reynolds
Guidelines recommend a confirmed diagnosis of atrial fibrillation (AF) to initiate oral anticoagulation in cryptogenic stroke (CS) patients. However, the intermittent nature of AF can make detection challenging with intermittent short-term cardiac monitoring. The purpose of this retrospective cohort study was to examine post-CS utilization of cardiac monitoring and associated clinical outcomes. Adults with incident hospitalization for CS were identified in the Optum® claims database and assessed for cardiac monitoring received poststroke. Patient were stratified into those with a long-term insertable cardiac monitor (ICM) vs external cardiac monitor (ECM) only. The timing of ICM placement poststroke was treated as a time-dependent covariate. The clinical outcomes of interest were time to AF diagnosis, oral anticoagulation usage, and all-cause mortality. A total of 12,994 patients met selection criteria for the analysis, of whom 1949 (15%) received an ICM and 11,045 (85%) received ECM only. In those who had received an ECM as their first monitoring modality, only 4.4% moved on to receive an ICM for longer-term monitoring. Use of ECM before ICM was associated with a longer time to AF diagnosis (median 336 vs 194 days). Compared to those with ECM only, ICM patients had a significantly lower rate of death (hazard ratio [HR] 0.70; P = .004), and faster time to AF diagnosis (HR 1.50; P <.0001) and anticoagulation initiation (HR 1.57; P <.0001) during follow-up of up to 5 years after CS. In a real-world study of CS patients, prolonged cardiac monitoring was associated with higher rates of AF detection and treatment, and higher odds of survival.

23 February 2021 in Open Heart
Verified
Journal Article
Open access
PDF file
BSBrad S Sutton
Brad S Sutton
SBSarah L Bermingham
Sarah L Bermingham
ADAlexander Diamantopoulos
Alexander Diamantopoulos
SRSarah Christine Rosemas
Sarah Christine Rosemas
STStelios I Tsintzos
Stelios I Tsintzos
MRMatthew R Reynolds
Matthew R Reynolds
Introduction Early use of insertable cardiac monitor (ICM) is recommended for patients with unexplained syncope following initial clinical workup, due to its superior ability to establish symptom-rhythm correlation compared with conventional testing (CONV). However, ICMs incur higher upfront costs, and the impact of additional diagnoses and resulting treatment on downstream costs and outcomes is unclear. We aimed to evaluate the cost-effectiveness of ICM compared with CONV for the diagnosis of arrhythmia in patients with unexplained syncope, from a US payer perspective. Methods A Markov model was developed to estimate lifetime costs and benefits of arrhythmia diagnosis with ICM versus CONV, considering all related diagnostic and arrhythmia-related treatment costs and consequences. Cohort characteristics and costs were informed by original claims database analyses. Risks of mortality, syncopal recurrence, injury due to syncope and quality of life consequences from syncopal events were identified from the literature. Results ICM was less costly and more effective than CONV. Most of the observed US$4532 cost savings were attributed to reduced downstream diagnostic testing. For every 1000 patients, ICM was projected to yield an additional 253 arrhythmia diagnoses and lead to treatment in an additional 168 patients. The ICM strategy resulted in overall improved outcomes (0.30 quality-adjusted life years gained), due to a reduction in syncope recurrence and injury resulting from arrhythmia treatment. The results were robust to changes in the base case parameters but sensitive to the model time horizon, underlying probability of syncope recurrence and prevalence of arrhythmias. Conclusions Our model projected that early ICM for the diagnosis of unexplained syncope reduced long-term costs, and led to an improvement in overall clinical outcomes by shortening time to arrhythmia treatment. The cost of ICM was outweighed by savings arising from fewer downstream diagnostic episodes, and the increased cost of treatment was counterbalanced by fewer syncope-related event costs.

7 January 2022 in Heart Rhythm O2
Verified
Journal Article
Open access
MMMoussa C. Mansour
Moussa C. Mansour
EGEmily M. Gillen
Emily M. Gillen
AGAudrey Garman
Audrey Garman
SRSarah Christine Rosemas
Sarah Christine Rosemas
NFNoreli Franco
Noreli Franco
JPJesse M. Pines
Jesse M. Pines
Compared with short-term electrocardiogram (ECG) monitors, insertable cardiac monitors (ICMs) have been shown to increase atrial fibrillation (AF) detection rates and the opportunity to treat recurrent AF in patients postablation. To examine healthcare utilization and clinical outcomes following AF ablation, in patients with vs without ICM. Retrospective analysis pooling Optum Clinformatics and Medicare Fee-for-service 5% Sample claims databases. Patients with an AF ablation between January 1, 2011, and March 31, 2018 who received an ICM implant within 1 year pre-/postablation were propensity score matched 1:3 to patients without ICM. Outcomes included AF-related healthcare utilization, medication use, and occurrence of composite severe cardiovascular events (stroke / transient ischemic attack, major bleeds, systemic embolism, AF- or heart failure–related hospitalization, or death). A total of 1000 ICM patients and 2998 non-ICM patients were included. During mean follow-up of 33 ± 16 months postablation, ICM patients experienced significantly fewer severe cardiovascular events (1.09 ± 2.22 vs 1.37 ± 4.19, P = .008) and associated costs ($20,757 vs $29,106, P = .0005). ICM patients had a greater number of AF-related clinic visits (16.8 vs 11.6 visits, P < .0001) and were more likely to receive a repeat ablation (38.7% vs 32.4%, P = .0003). Total all-cause costs during follow-up were not statistically different. Discontinuation of oral anticoagulation was higher in ICM patients at 1 year (44% vs 31%, P < .0001) and 2 years (73% vs 64%, P = .0012). A shift from acute, reactive care to routine outpatient management was observed in patients with long-term ECG monitoring. Results suggest closer patient management in patients with long-term monitoring after an AF ablation and an improvement in outcomes, at similar overall cost.

16 August 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
CFCamille G. Frazier-Mills
Camille G. Frazier-Mills
LJLawrence C. Johnson
Lawrence C. Johnson
YXYing Xia
Ying Xia
SRSarah Christine Rosemas
Sarah Christine Rosemas
NFNoreli Franco
Noreli Franco
SPSean D. Pokorney
Sean D. Pokorney
Despite advances in syncope evaluation strategies and risk stratification, the high cost of syncope is largely driven by extensive and often repetitive testing. This analysis of a large deidentified US claims database compared the use of diagnostic tests, therapeutic procedures, and the recurrence rate of acute syncope events before and after placement of an insertable cardiac monitor (ICM) in syncope patients. The patients had a minimum of 1 year of continuous enrollment before and 2 years after ICM placement. Among 2140 patients identified, a statistically significant reduction in the use of 14 out of 18 tests was observed during follow-up compared with pre-ICM testing. During the 2-year follow-up, 28.3% of patients underwent cardiac therapeutic interventions after a median of 127 days. Significantly fewer patients experienced acute syncope events during the 1st and 2nd years of ICM follow-up compared with the 1-year pre-ICM period, and the frequency of events per patient also decreased. In conclusion, reductions in diagnostic testing and acute syncope events were observed after ICM placement in a large real-world cohort of unexplained syncope patients. Further studies are needed to prospectively assess the impact of ICM vs. short-term monitoring on patient outcomes and healthcare utilization.