Jiani Zhou

Dr. Jiani Zhou

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2024 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
GPGraham Peigh
Graham Peigh
JZJiani Zhou
Jiani Zhou
SRSarah C. Rosemas
Sarah C. Rosemas
ARAnthony I. Roberts
Anthony I. Roberts
CLColleen Longacre
Colleen Longacre
RPRod S. Passman
Rod S. Passman

30 July 2024 in Circulation
Verified
Journal Article
Open access
GPGraham Peigh
Graham Peigh
JZJiani Zhou
Jiani Zhou
SRSarah Christine Rosemas
Sarah Christine Rosemas
ARAnthony I. Roberts
Anthony I. Roberts
CLColleen Longacre
Colleen Longacre
RPRod S. Passman
Rod S. Passman
BACKGROUND: Current estimates of atrial fibrillation (AF)–associated mortality rely on claims- or clinical-derived diagnoses of AF, limit AF to a binary entity, or are confounded by comorbidities. The objective of the present study is to assess the association between device-recognized AF and mortality among patients with cardiac implantable electronic devices capable of sensitive and continuous atrial arrhythmia detection. Secondary outcomes include relative mortality among cohorts with no AF, paroxysmal AF, persistent AF, and permanent AF. METHODS: Using the deidentified Optum Clinformatics US claims database (2015 to 2020) linked to the Medtronic CareLink database, we identified individuals with a cardiac implantable electronic device who transmitted data ≥6 months after implantation. AF burden was assessed during the first 6 months after implantation (baseline period). Subsequent mortality, assessed from claims data, was compared between patients with and without AF, with adjustment for age, geographic region, insurance type, Charlson Comorbidity Index, and implantation year. RESULTS: Of 21 391 patients (age, 72.9±10.9 years; 56.3% male) analyzed, 7798 (36.5%) had device-recognized AF. During a mean of 22.4±12.9 months (median, 20.1 [12.8–29.7] months) of follow-up, the overall incidence of mortality was 13.5%. Patients with AF had higher adjusted all-cause mortality than patients without AF (hazard ratio, 1.29 [95% CI, 1.20–1.39]; P <0.001). Among those with AF, patients with nonparoxysmal AF had the greatest risk of mortality (persistent AF versus paroxysmal AF: hazard ratio, 1.36 [95% CI, 1.18–1.58]; P <.001; permanent AF versus paroxysmal AF: hazard ratio, 1.23 [95% CI, 1.14–1.34]; P <.001). CONCLUSIONS: After adjustment for potential confounding factors, the presence of AF was associated with higher mortality in our cohort of patients with cardiac implantable electronic devices. Among those with AF, nonparoxysmal AF was associated with the greatest risk of mortality.

19 June 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
DWDavid J Wright
David J Wright
MTMaría Emilce Trucco
María Emilce Trucco
JZJiani Zhou
Jiani Zhou
CWClaudia Wolff
Claudia Wolff
RHReece Holbrook
Reece Holbrook
MEMikhael F El-Chami
Mikhael F El-Chami
Cardiac implantable electronic device (CIED) infections are a burden to hospitals and costly for healthcare systems. Chronic kidney disease (CKD) increases the risk of CIED infections, but its differential impact on healthcare utilization, costs, and outcomes is not known. This retrospective analysis used de-identified Medicare Fee-for-Service claims to identify patients implanted with a CIED from July 2016 to December 2020. Outcomes were defined as hospital days and costs within 12 months post-implant, post-infection CKD progression, and mortality. Generalized linear models were used to calculate results by CKD and infection status while controlling for other comorbidities, with differences between cohorts representing the incremental effect associated with CKD. A total of 584 543 patients had a CIED implant, of which 26% had CKD and 1.4% had a device infection. The average total days in hospital for infected patients was 23.5 days with CKD vs. 14.5 days (P < 0.001) without. The average cost of infection was $121 756 with CKD vs. $55 366 without (P < 0.001), leading to an incremental cost associated with CKD of $66 390. Infected patients with CKD were more likely to have septicaemia or severe sepsis than those without CKD (11.0 vs. 4.6%, P < 0.001). After infection, CKD patients were more likely to experience CKD progression (hazard ratio 1.26, P < 0.001) and mortality (hazard ratio 1.89, P < 0.001). Cardiac implantable electronic device infection in patients with CKD was associated with more healthcare utilization, higher cost, greater disease progression, and greater mortality compared to patients without CKD.