In shallow geothermal energy systems (SGES) thermal conduction can be considered the dominant process in the heat transfer between the primary circuit (borehole heat exchanger or thermoactive geostructure) and the surrounding ground. Thus, a proper characterization of soil thermal properties, namely of its thermal conductivity, is mandatory for evaluating this energy exchange. There are difficulties associated to the assessment of soil thermal conductivity by laboratory methods related, among other factors, to the samples’ quality and to the measuring method itself. The purpose of this work is to analyse the effect of changing test control parameters in thermal conductivity measurements in transient conditions by means of a high accuracy thermal probe in both dry and fully saturated states. In order to eliminate potential measurements’ deviations and errors due to sample variability the same reconstituted samples were used several times. In each condition the sand samples were systematically tested under different ambient temperatures (10ºC, 20ºC, and 40ºC) controlled by means of a climatic chamber. The effects of changing the tests heating time and imposed thermal fluxes were also analysed.
Shallow Geothermal Energy (SGE) exchanges heat with the ground. In continuous, long-term operation, the initial temperature field can be disturbed, and subsurface thermal changes can be developed. In this paper, the thermal impact of a SGE system under a Mediterranean climate is handled. Temperature monitoring was conducted on 15 investigation boreholes equipped with a total of 92 thermal sensors placed at specific depths. Investigation boreholes were drilled 1–2 m from SGE system borehole heat exchangers installed in a university building. The analysis handles a one-year monitoring period of SGE system operation. Temperature depth profiles, reaching up to 140 m depth, were registered with a 10 min time step, resulting in a large amount of data. Ground thermal conductivity was estimated experimentally and semi-empirically, allowing us to obtain, using a numerical model, the initial undisturbed ground temperature profiles and compare them with the monitored values. Climate data were recorded by the university meteorological station. Globally, the measured and computed data were coherent, and a non-negligible impact of the SGE system operation in the first year was observed. The building orientation as well as the nearby departments had significant impacts on the shallow ground temperature. Maximum ground temperature changes observed at depths higher than 10–20 m, ranging from 2 to 3 °C as observed in different boreholes, indicate that the system is operating efficiently.
Shallow Geothermal Energy (SGE) exchanges heat with the ground. In continuous long-term operation, the initial temperature field can be disturbed, and subsurface thermal plumes can be developed. In this paper, the thermal impact of a SGE system under Mediterranean climate is handled. Temperature recordings from 104 thermal probes placed in depth along 15 monitoring boreholes are analysed. Those boreholes were drilled 1-2m from thermos-active boreholes of the case study system installed in a university building. The analysis handles one year of SGE system operation. Temperature depth profiles, reaching up to 140 m depth, were registered with a 10-minute time-step resulting in a large amount of data. Ground thermal conductivity was estimated experimentally and semi-empirically allowing to compute the initial undisturbed ground temperature profiles and compare it with the monitored values. Climate data was recorded by the university meteorological station. Globally, the measured and computed data were coherent and a non-negligible impact of the SGE system operation in the first year was observed. The building orientation as well as the nearby departments had significant impacts on shallow ground temperature. Maximum ground temperature changes, ranging from 2 to 3º C as observed in different boreholes indicating that the system is operating efficiently.