José Marques Lapa

Prof. José Marques Lapa

Engnharia Civil, RISCO - Universidade de Aveiro, Aveiro, Portugal
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Applied Energy
Verified
Journal Article
Closed access
António FigueiredoAntónio Figueiredo
António Figueiredo
Romeu Silva VicenteRomeu Silva Vicente
Romeu Silva Vicente
JLJosé Marques Lapa
José Marques Lapa
CCClaudino Cardoso
Claudino Cardoso
Fernanda RodriguesFernanda Rodrigues
Fernanda Rodrigues
JKJerome Kaempf
Jerome Kaempf

1 June 2016 in Construction and Building Materials
Verified
Journal Article
Closed access
António FigueiredoAntónio Figueiredo
António Figueiredo
JLJosé Marques Lapa
José Marques Lapa
Romeu Silva VicenteRomeu Silva Vicente
Romeu Silva Vicente
CCClaudino Cardoso
Claudino Cardoso

5 January 2024 in Geosciences
Verified
Journal Article
Open access
PDF file
KAKamar Aljundi
Kamar Aljundi
AVAna Vieira
Ana Vieira
JLJosé Marques Lapa
José Marques Lapa
António FigueiredoAntónio Figueiredo
António Figueiredo
Rafaela CardosoRafaela Cardoso
Rafaela Cardoso
Shallow Geothermal Energy (SGE) exchanges heat with the ground. In continuous, long-term operation, the initial temperature field can be disturbed, and subsurface thermal changes can be developed. In this paper, the thermal impact of a SGE system under a Mediterranean climate is handled. Temperature monitoring was conducted on 15 investigation boreholes equipped with a total of 92 thermal sensors placed at specific depths. Investigation boreholes were drilled 1–2 m from SGE system borehole heat exchangers installed in a university building. The analysis handles a one-year monitoring period of SGE system operation. Temperature depth profiles, reaching up to 140 m depth, were registered with a 10 min time step, resulting in a large amount of data. Ground thermal conductivity was estimated experimentally and semi-empirically, allowing us to obtain, using a numerical model, the initial undisturbed ground temperature profiles and compare them with the monitored values. Climate data were recorded by the university meteorological station. Globally, the measured and computed data were coherent, and a non-negligible impact of the SGE system operation in the first year was observed. The building orientation as well as the nearby departments had significant impacts on the shallow ground temperature. Maximum ground temperature changes observed at depths higher than 10–20 m, ranging from 2 to 3 °C as observed in different boreholes, indicate that the system is operating efficiently.

17 September 2009
Verified
Conference Paper
Closed access
LSL.M.C. Simoes
L.M.C. Simoes
JLJosé Marques Lapa
José Marques Lapa

23 August 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
KAKamar Aljundi
Kamar Aljundi
AVAna Vieira
Ana Vieira
JLJosé Marques Lapa
José Marques Lapa
António FigueiredoAntónio Figueiredo
António Figueiredo
Rafaela CardosoRafaela Cardoso
Rafaela Cardoso
Shallow Geothermal Energy (SGE) exchanges heat with the ground. In continuous long-term operation, the initial temperature field can be disturbed, and subsurface thermal plumes can be developed. In this paper, the thermal impact of a SGE system under Mediterranean climate is handled. Temperature recordings from 104 thermal probes placed in depth along 15 monitoring boreholes are analysed. Those boreholes were drilled 1-2m from thermos-active boreholes of the case study system installed in a university building. The analysis handles one year of SGE system operation. Temperature depth profiles, reaching up to 140 m depth, were registered with a 10-minute time-step resulting in a large amount of data. Ground thermal conductivity was estimated experimentally and semi-empirically allowing to compute the initial undisturbed ground temperature profiles and compare it with the monitored values. Climate data was recorded by the university meteorological station. Globally, the measured and computed data were coherent and a non-negligible impact of the SGE system operation in the first year was observed. The building orientation as well as the nearby departments had significant impacts on shallow ground temperature. Maximum ground temperature changes, ranging from 2 to 3º C as observed in different boreholes indicating that the system is operating efficiently.