Liang Liu

Dr. Liang Liu

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Talanta
Verified
Journal Article
Closed access
ZMZhang Mi
Zhang Mi
CZChen Zhongqiang
Chen Zhongqiang
JCJiang Caiyun
Jiang Caiyun
LYLiu Yanan
Liu Yanan
WJWu Jianhua
Wu Jianhua
LLLiang Liu
Liang Liu

17 February 2023 in Talanta
Verified
Journal Article
Closed access
BSBo Sun
Bo Sun
JLJiuyang Liu
Jiuyang Liu
PCPei Cai
Pei Cai
JWJianhua Wu
Jianhua Wu
WLWei Liu
Wei Liu
LLLiang Liu
Liang Liu

30 October 2023 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
WLWenjing Li
Wenjing Li
YLYang Li
Yang Li
JCJunlong Cai
Junlong Cai
YWYue Wang
Yue Wang
YLYanan Liu
Yanan Liu
LLLiang Liu
Liang Liu
Systemic antifungal agents are essential for high-risk patients undergoing immunosuppressive therapy or cancer chemotherapy because of the rapid increase in opportunistic fungal infections. Therapeutic drug monitoring is crucial to ensuring the efficacy and safety of antifungal agents owing to their pharmacokinetic variability. In the present study, we developed and validated a quantitative method for the simultaneous detection of seven commonly used antifungal drugs (amphotericin B, isavuconazole, voriconazole, fluconazole, posaconazole, caspofungin, and micafungin) using liquid chromatography-tandem mass spectrometry. Methanol (containing 0.1% formic acid) was used for protein precipitation and only 50 μL of serum was required for the analysis. Chromatographic separation was conducted using a Waters Acquity UPLC C8 column, and one stable isotope-labeled agent and two analogs were used as internal standards. The calibration curves ranged from 0.1 to 50 μg/mL for all agents, and the correlation coefficient (R2) for all calibration curves was above 0.9835. The intra-day precision (1.2–11.2%), inter-day precision (2.4–13.2%), and mean bias values (−10.9 to 13.6%) were within an acceptable range of ±15%. Successful implementation of the developed method in clinical practice would facilitate the effective monitoring of these antifungal agents.

26 September 2022 in Analytical Chemistry
Verified
Journal Article
Closed access
LLLiang Liu
Liang Liu
XCXiuyu Chen
Xiuyu Chen
BSBo Sun
Bo Sun

7 December 2022 in Pharmacogenomics
Verified
Journal Article
Closed access
JZJianxun Zhong
Jianxun Zhong
KYKun Yang
Kun Yang
MZMi Zhang
Mi Zhang
WJWu Jianhua
Wu Jianhua
LLLiang Liu
Liang Liu
Background: The correlation between SLCO1B3 T334G polymorphisms and mycophenolate mofetil (MMF) adverse reactions in kidney recipients is unknown. Methods: A single-center, retrospective study was ...

12 June 2024 in RSC Advances
Verified
Journal Article
Open access
PDF file
LLLiang Liu
Liang Liu
BSBo Sun
Bo Sun
JCJunlong Cai
Junlong Cai
JWJiajun Wang
Jiajun Wang
WLWei Liu
Wei Liu
WJWu Jianhua
Wu Jianhua
Monoclonal antibodies (mAbs) are pivotal therapeutic agents for various diseases, and effective treatment hinges on attaining a specific threshold concentration of mAbs in patients. With the rising adoption of combination therapy involving multiple mAbs, there arises a clinical demand for multiplexing assays capable of measuring the concentrations of these mAbs. However, minimizing the complexity of serum samples while achieving rapid and accurate quantification is difficult. In this work, we introduced a novel method termed nano-surface and molecular orientation limited (nSMOL) proteolysis for the fragment of antigen binding (Fab) region-selective proteolysis of co-administered trastuzumab and pertuzumab based on the pore size difference between the protease nanoparticles (∼200 nm) and the resin-captured antibody (∼100 nm). The hydrolyzed peptide fragments were then quantified using liquid chromatography-tandem mass spectrometry (LC-MS/MS). In this process, the digestion time is shortened, and the produced digestive peptides are greatly reduced, thereby minimizing sample complexity and increasing detection accuracy. Assay linearity was confirmed within the ranges of 0.200–200 μg mL−1 for trastuzumab and 0.300–200 μg mL−1 for pertuzumab. The intra- and inter-day precision was within 9.52% and 8.32%, except for 12.5% and 10.8% for the lower limit of quantitation, and the accuracy (bias%) was within 6.3%. Additionally, other validation parameters were evaluated, and all the results met the acceptance criteria of the guiding principles. Our method demonstrated accuracy and selectivity for the simultaneous determination of trastuzumab and pertuzumab in clinical samples, addressing the limitation of ligand binding assays incapable of simultaneously quantifying mAbs targeting the same receptor. This proposed assay provides a promising technical approach for realizing clinical individualized precise treatment, especially for co-administered mAbs.