Empirically prescribed standard dosing regimens of antibacterial agents may result in insufficient or excess plasma concentrations with persistently poor clinical outcomes, especially for patients in intensive care units (ICUs). Therapeutic drug monitoring (TDM) of antibacterial agents can guide dose adjustments to benefit patients. In this study, we developed a robust, sensitive, and simple liquid chromatography-tandem mass spectrometry (LC–MS/MS) platform for the quantification of 14 antibacterial and antifungal agents (beta-lactams piperacillin, cefoperazone, and meropenem; beta-lactamase inhibitors tazobactam and sulbactam; antifungal agents fluconazole, caspofungin, posaconazole, and voriconazole; and daptomycin, vancomycin, teicoplanin, linezolid, and tigecycline) that can be used for patients with severe infection. This assay requires only 100 µL of serum with rapid protein precipitation. Chromatographic analysis was performed using a Waters Acquity UPLC C8 column. Three stable isotope-labeled antibacterial agents and one analogue were used as internal standards. Calibration curves ranged from 0.1–100 μg/mL, 0.1–50 μg/mL, and 0.3–100 μg/mL for different drugs, and all correlation coefficients were greater than 0.9085. Intra- and inter-day imprecision and inaccuracy values were below 15%. After validation, this new method was successfully employed for TDM in routine practice.
12 April 2024 in Int. Journal of Clinical Pharmacology and Therapeutics
High-dose tigecycline is gradually being introduced for the treatment of serious infectious diseases due to the increasing difficulty in treating pan-resistant bacterial infections. However, the safety of high-dose tigecycline is controversial. We report the case of a 76-year-old female patient with cerebral hemorrhage who received high-dose tigecycline (100 mg q12h) with other drugs for ventilator-associated pneumonia. 25 days after admission, she developed acute liver failure, mainly manifested by abnormally high bilirubin, coagulation dysfunction, and gastrointestinal hemorrhage with hemorrhagic shock. According to the updated Roussel Uclaf causality assessment method, the patient's acute liver injury was most likely caused by tigecycline. What in known about this subject - Tigecycline was probably the main cause of the patient's acute liver injury according to the updated Roussel Uclaf causality assessment method. - We described the onset and medication of our patient in detail, and the pattern and severity of DILI, discussed the correlation between high-dose tigecycline and ALF, and summarized the risk factors, and precautions in the application of high-dose tigecycline. What this study adds - This is the first case of acute liver failure with death caused by a long duration of high-dose tigecycline.
Background: The correlation between SLCO1B3 T334G polymorphisms and mycophenolate mofetil (MMF) adverse reactions in kidney recipients is unknown. Methods: A single-center, retrospective study was ...
Monoclonal antibodies (mAbs) are pivotal therapeutic agents for various diseases, and effective treatment hinges on attaining a specific threshold concentration of mAbs in patients. With the rising adoption of combination therapy involving multiple mAbs, there arises a clinical demand for multiplexing assays capable of measuring the concentrations of these mAbs. However, minimizing the complexity of serum samples while achieving rapid and accurate quantification is difficult. In this work, we introduced a novel method termed nano-surface and molecular orientation limited (nSMOL) proteolysis for the fragment of antigen binding (Fab) region-selective proteolysis of co-administered trastuzumab and pertuzumab based on the pore size difference between the protease nanoparticles (∼200 nm) and the resin-captured antibody (∼100 nm). The hydrolyzed peptide fragments were then quantified using liquid chromatography-tandem mass spectrometry (LC-MS/MS). In this process, the digestion time is shortened, and the produced digestive peptides are greatly reduced, thereby minimizing sample complexity and increasing detection accuracy. Assay linearity was confirmed within the ranges of 0.200–200 μg mL−1 for trastuzumab and 0.300–200 μg mL−1 for pertuzumab. The intra- and inter-day precision was within 9.52% and 8.32%, except for 12.5% and 10.8% for the lower limit of quantitation, and the accuracy (bias%) was within 6.3%. Additionally, other validation parameters were evaluated, and all the results met the acceptance criteria of the guiding principles. Our method demonstrated accuracy and selectivity for the simultaneous determination of trastuzumab and pertuzumab in clinical samples, addressing the limitation of ligand binding assays incapable of simultaneously quantifying mAbs targeting the same receptor. This proposed assay provides a promising technical approach for realizing clinical individualized precise treatment, especially for co-administered mAbs.