7 August 2021 in Current Cardiology Reports
Verified
Journal Article
Open access
PDF file
DHDerk ten Hove
Derk ten Hove
Riemer H.J.A. SlartRiemer H.J.A. Slart
Riemer H.J.A. Slart
Bhanu SinhaBhanu Sinha
Bhanu Sinha
Andor W. J. M. GlaudemansAndor W. J. M. Glaudemans
Andor W. J. M. Glaudemans
RBR.P.J. Budde
R.P.J. Budde
Purpose of Review: Additional imaging modalities, such as FDG-PET/CT, have been included into the workup for patients with suspected infective endocarditis, according to major international guidelines published in 2015. The purpose of this review is to give an overview of FDG-PET/CT indications and standardized approaches in the setting of suspected infective endocarditis. Recent Findings: There are two main indications for performing FDG-PET/CT in patients with suspected infective endocarditis: (i) detecting intracardiac infections and (ii) detection of (clinically silent) disseminated infectious disease. The diagnostic performance of FDG-PET/CT for intracardiac lesions depends on the presence of native valves, prosthetic valves, or implanted cardiac devices, with a sensitivity that is poor for native valve endocarditis and cardiac device-related lead infections, but much better for prosthetic valve endocarditis and cardiac device-related pocket infections. Specificity is high for all these indications. The detection of disseminated disease may also help establish the diagnosis and/or impact patient management. Summary: Based on current evidence, FDG-PET/CT should be considered for detection of disseminated disease in suspected endocarditis. Absence of intracardiac lesions on FDG-PET/CT cannot rule out native valve endocarditis, but positive findings strongly support the diagnosis. For prosthetic valve endocarditis, standard use of FDG-PET/CT is recommended because of its high sensitivity and specificity. For implanted cardiac devices, FDG-PET/CT is also recommended, but should be evaluated with careful attention to clinical context, because its sensitivity is high for pocket infections, but low for lead infections. In patients with prosthetic valves with or without additional aortic prosthesis, combination with CTA should be considered. Optimal timing of FDG-PET/CT is important, both during clinical workup and technically (i.e., post tracer injection). In addition, procedural standardization is key and encompasses patient preparation, scan acquisition, reconstruction, subsequent analysis, and clinical interpretation. The recommendations discussed here will hopefully contribute to improved standardization and enhanced performance of FDG-PET/CT in the clinical management of patients with suspected infective endocarditis.

27 June 2020 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
DHDerk ten Hove
Derk ten Hove
GTG. Treglia
G. Treglia
RSR. H. J. A. Slart
R. H. J. A. Slart
KDK. Damman
K. Damman
MWM. Wouthuyzen-Bakker
M. Wouthuyzen-Bakker
AGA. W. J. M. Glaudemans
A. W. J. M. Glaudemans
Background: Left ventricular assist devices (LVADs) are increasingly used for the treatment of advanced heart failure. LVADs improve quality of life and decrease mortality, but the driveline carries substantial risk for major infections. These device-related LVAD and driveline infections are difficult to diagnose with conventional imaging. We reviewed and analysed the current literature on the additive value of 18F-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) imaging for the diagnosis of LVAD-related infections.” Materials/methods: We performed a systematic literature review using several databases from their inception until the 31st of December, 2019. Studies investigating the diagnostic performance of FDG-PET/CT in patients with suspected LVAD infection were retrieved. After a bias risk assessment using QUADAS-2, a study-aggregate meta-analysis was performed on a per examination-based analysis. Results: A total of 10 studies were included in the systematic review, eight of which were also eligible for study-aggregate meta-analysis. For the meta-analysis, a total of 256 FDG-PET/CT scans, examining pump/pocket and/or driveline infection, were acquired in 230 patients. Pooled sensitivity of FDG-PET/CT was 0.95 (95% confidence interval (CI) 0.89–0.97) and pooled specificity was 0.91 (95% CI 0.54–0.99) for the diagnosis of device-related infection. For pump/pocket infection, sensitivity and specificity of FDG-PET/CT were 0.97 (95%CI 0.69–1.00) and 0.93 (95%CI 0.64–0.99), respectively. For driveline infection, sensitivity and specificity were 0.96 (95%CI 0.88–0.99) and 0.99 (95%CI 0.13–1.00) respectively. Significant heterogeneity existed across studies for specificity, mostly caused by differences in scan procedures. Predefined criteria for suspicion of LVAD and/or driveline infection were lacking in all included studies. Conclusions: FDG-PET/CT is a valuable tool for assessment of device-related infection in LVAD patients, with high sensitivity and high, albeit variable, specificity. Standardization of FDG-PET/CT procedures and criteria for suspected device-related LVAD infections are needed for consistent reporting of FDG-PET/CT scans.

21 June 2024 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
DHDerk ten Hove
Derk ten Hove
Riemer H.J.A. SlartRiemer H.J.A. Slart
Riemer H.J.A. Slart
Andor W. J. M. GlaudemansAndor W. J. M. Glaudemans
Andor W. J. M. Glaudemans
DPDouwe F. Postma
Douwe F. Postma
AGA. Gomes
A. Gomes
Bhanu SinhaBhanu Sinha
Bhanu Sinha
Introduction: Prosthetic valve endocarditis (PVE) is a serious complication of prosthetic valve implantation, with an estimated yearly incidence of at least 0.4-1.0%. The Duke criteria and subsequent modifications have been developed as a diagnostic framework for infective endocarditis (IE) in clinical studies. However, their sensitivity and specificity are limited, especially for PVE. Furthermore, their most recent versions (ESC2015 and ESC2023) include advanced imaging modalities, e.g., cardiac CTA and [18F]FDG PET/CT as major criteria. However, despite these significant changes, the weighing system using major and minor criteria has remained unchanged. This may have introduced bias to the diagnostic set of criteria. Here, we aimed to evaluate and improve the predictive value of the modified Duke/ESC 2015 (MDE2015) criteria by using machine learning algorithms. Methods: In this proof-of-concept study, we used data of a well-defined retrospective multicentre cohort of 160 patients evaluated for suspected PVE. Four machine learning algorithms were compared to the prediction of the diagnosis according to the MDE2015 criteria: Lasso logistic regression, decision tree with gradient boosting (XGBoost), decision tree without gradient boosting, and a model combining predictions of these (ensemble learning). All models used the same features that also constitute the MDE2015 criteria. The final diagnosis of PVE, based on endocarditis team consensus using all available clinical information, including surgical findings whenever performed, and with at least 1 year follow up, was used as the composite gold standard. Results: The diagnostic performance of the MDE2015 criteria varied depending on how the category of ‘possible’ PVE cases were handled. Considering these cases as positive for PVE, sensitivity and specificity were 0.96 and 0.60, respectively. Whereas treating these cases as negative, sensitivity and specificity were 0.74 and 0.98, respectively. Combining the approaches of considering possible endocarditis as positive and as negative for ROC-analysis resulted in an excellent AUC of 0.917. For the machine learning models, the sensitivity and specificity were as follows: logistic regression, 0.92 and 0.85; XGBoost, 0.90 and 0.85; decision trees, 0.88 and 0.86; and ensemble learning, 0.91 and 0.85, respectively. The resulting AUCs were, in the same order: 0.938, 0.937, 0.930, and 0.941, respectively. Discussion: In this proof-of-concept study, machine learning algorithms achieved improved diagnostic performance compared to the major/minor weighing system as used in the MDE2015 criteria. Moreover, these models provide quantifiable certainty levels of the diagnosis, potentially enhancing interpretability for clinicians. Additionally, they allow for easy incorporation of new and/or refined criteria, such as the individual weight of advanced imaging modalities such as CTA or [18F]FDG PET/CT. These promising preliminary findings warrant further studies for validation, ideally in a prospective cohort encompassing the full spectrum of patients with suspected IE.

24 October 2023 in British Journal of Radiology
Verified
Journal Article
Open access
HTHendrea Sanne Aletta Tingen
Hendrea Sanne Aletta Tingen
Gijs van PraaghGijs van Praagh
Gijs van Praagh
PNPieter H. Nienhuis
Pieter H. Nienhuis
ATAlwin Tubben
Alwin Tubben
NRNick van Rijsewijk
Nick van Rijsewijk
Riemer H.J.A. SlartRiemer H.J.A. Slart
Riemer H.J.A. Slart
Cardiovascular diseases (CVD) are the leading cause of death worldwide and have an increasing impact on society. Precision medicine, in which optimal care is identified for an individual or a group of individuals rather than for the average population, might provide significant health benefits for this patient group and decrease CVD morbidity and mortality. Molecular imaging provides the opportunity to assess biological processes in individuals in addition to anatomical context provided by other imaging modalities and could prove to be essential in the implementation of precision medicine in CVD. New developments in single-photon emission computed tomography (SPECT) and positron emission tomography (PET) systems, combined with rapid innovations in promising and specific radiopharmaceuticals, provide an impressive improvement of diagnostic accuracy and therapy evaluation. This may result in improved health outcomes in CVD patients, thereby reducing societal impact. Furthermore, recent technical advances have led to new possibilities for accurate image quantification, dynamic imaging, and quantification of radiotracer kinetics. This potentially allows for better evaluation of disease activity over time and treatment response monitoring. However, the clinical implementation of these new methods has been slow. This review describes the recent advances in molecular imaging and the clinical value of quantitative PET and SPECT in various fields in cardiovascular molecular imaging, such as atherosclerosis, myocardial perfusion and ischemia, infiltrative cardiomyopathies, systemic vascular diseases, and infectious cardiovascular diseases. Moreover, the challenges that need to be overcome to achieve clinical translation are addressed, and future directions are provided.

24 January 2018 in Emergency Medicine Journal
Verified
Journal Article
Open access
PDF file
VWVeera K van Wijnen
Veera K van Wijnen
DHDerk ten Hove
Derk ten Hove
RGReinold O.B. Gans
Reinold O.B. Gans
WNWybe Nieuwland
Wybe Nieuwland
ARArie M van Roon
Arie M van Roon
MHMark P M Harms
Mark P M Harms
Introduction Orthostasis is a frequent trigger for (pre)syncope but some forms of orthostatic (pre)syncope have a worse prognosis than others. Routine assessment of orthostatic BP in the ED can detect classic orthostatic hypotension, but often misses these other forms of orthostatic (pre)syncope. This study aimed to determine the frequency of abnormal orthostatic BP recovery patterns in patients with (pre)syncope by using continuous non-invasive BP monitoring. Methods We performed a prospective cohort study in suspected patients with (pre)syncope in the ED of a tertiary care teaching hospital between January and August 2014. Orthostatic BP was measured during the active lying-to-standing test with Nexfin, a continuous non-invasive finger arterial pressure measurement device. Orthostatic BP recovery patterns were defined as normal BP recovery, initial orthostatic hypotension, delayed BP recovery, classic orthostatic hypotension and reflex-mediated hypotension. Results Of 116 patients recruited, measurements in 111 patients (age 63 years, 51% male) were suitable for analysis. Classic orthostatic hypotension was the most prevalent abnormal BP pattern (19%), but only half of the patients received a final diagnosis of orthostatic hypotension. Initial orthostatic hypotension and delayed BP recovery were present in 20% of the patients with (pre)syncope of whom 45% were diagnosed as unexplained syncope. Reflex-mediated hypotension was present in 4% of the patients. Conclusion Continuous non-invasive BP measurement can potentially identify more specific and concerning causes of orthostatic (pre)syncope. Correct classification is important because of different short-term and long-term clinical implications.

27 December 2022 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
DHDerk ten Hove
Derk ten Hove
AWAli R Wahadat
Ali R Wahadat
RSRiemer H J A Slart
Riemer H J A Slart
MWMarjan Wouthuyzen-Bakker
Marjan Wouthuyzen-Bakker
GMGianclaudio Mecozzi
Gianclaudio Mecozzi
AGAndor W J M Glaudemans
Andor W J M Glaudemans
Left ventricular assist devices (LVADs) improve quality of life and survival in patients with advanced heart failure, but device-related infections (DRIs) remain cumbersome. We evaluated the diagnostic capability of [18F]FDG PET/CT, factors affecting its accuracy, and the additive value of semi-quantitative analysis for the diagnosis of DRI. LVAD recipients undergoing [18F]FDG PET/CT between 2012 and 2020 for suspected DRI were retrospectively included. [18F]FDG PET/CT was performed and evaluated in accordance with EANM guidelines. The final diagnosis of DRI, based on multidisciplinary consensus and findings during surgery, whenever performed, was used as the reference for diagnosis. 41 patients were evaluated for 59 episodes of suspected DRI. The clinical evaluation established driveline infection in 32 (55%) episodes, central device infection in 6 (11%), and combined infection in 2 (4%). Visual analysis of [18F]FDG PET/CT achieved a sensitivity and specificity for driveline infections of 0.79 and 0.71, respectively, whereas semi-quantitative analysis achieved a sensitivity and specificity of 0.94 and 0.83, respectively. For central device component infection, visual analysis of [18F]FDG PET/CT achieved a sensitivity and specificity of 0.75 and 0.60, respectively. Semi-quantitative analysis using SUVratio achieved a sensitivity and specificity of 1.0 and 0.8, respectively. The increase of specificity for central component infection was statistically significant (P = 0.05). [18F]FDG PET/CT reliably predicts the presence of DRI in LVAD recipients. Semi-quantitative analysis may increase the specificity of [18F]FDG PET/CT for the analysis of central device component infection and should be considered in equivocal cases after visual analysis.